The text of a manual · part 11 of 38
Trakker Antares 2400 Family System Manual: Chapter 4 - Running Diagnostics, pages 87 to 96
Pages 87 to 96 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 87
4
Running Diagnostics
This chapter explains how to run diagnostics on the terminal to help analyze hardware, application, and firmware problems. This chapter covers these topics: • Available diagnostics • Running diagnostics from the menu system • Defining the diagnostics screens • Error numbers and messages
Trakker Antares 2400 Family System Manual
67
Page 88
Chapter 4 - Running Diagnostics nugget
39 AGaramond
What Diagnostics Are Available? You can run diagnostics on the Trakker Antares® terminals to help analyze hardware and firmware problems, fix application problems, and view system information. You use the TRAKKER Antares 2400 Menu System to run diagnostics. This chapter lists the diagnostics in alphabetical order. Use the following tables to find the software, hardware, and system diagnostics you want to run. Note: Diagnostics are not available on 246X terminals, because 246X terminals do not use the TRAKKER Antares 2400 Menu System. Diagnostics Listed by Category Hardware Diagnostic Test Battery/PIC Status
Page Number
Description Shows the power level of the backup battery. Indicates the backup battery’s current volts, temperature, and charging status.
73
Reports main board and the I/O board temperature, and the status of the EEPROM checksum and the master bus.
68
Beeper Test
Sounds a series of beeps to test the beeper by using a range of beep volumes and beep frequencies.
76
Display Test
Tests and turns on the pixels on the screen to make sure all areas of the screen are working correctly.
77
Hardware Configuration
Lists the terminal’s hardware components that were installed at the Intermec factory, including the RF country code.
80
Keypad Test
Shows the hexadecimal, decimal, and scan code value for any key or key combination on the keyboard.
82
Radio Test
(RF terminals only) Tests the radio to make sure it is working.
83
Scanner Test
Tests the laser scanner to make sure it is working.
84
Trakker Antares 2400 Family System Manual
Page 89
nugget
39 AGaramond Chapter 4 - Running Diagnostics
Diagnostics Listed by Category (continued) System Diagnostic Test Access Point
Description (RF terminals only) Lists information about the access point the RF terminal is communicating with across the network.
Page Number 72
Application Efficiency
Displays the application efficiency percentage to help determine the impact that the application has on the terminal’s battery power.
72
Code Verify
Determines if the terminal’s firmware has been overwritten.
77
Malloc Application Information
Shows how memory is allocated and used by the current application.
82
Malloc Firmware Information
Shows how memory is allocated and used in the terminal firmware.
83
Serial Port Test
Tests serial communications between the terminal and the host computer or serial device.
85
Subsystem Versions
Lists the version of each major firmware subsystem loaded on the terminal.
86
Software Diagnostic Test
Description
Application Events
Shows the current status of each application event to help debug applications.
73
Clear Task Profiles
Clears the Task Status counters so that you can begin accumulating new task statistics for the Task Status screen and the Application Efficiency screen.
76
Error Logger
Lists any errors that the firmware did not expect.
78
Font Test
Lists the double-byte font, if any, that is loaded in the terminal.
79
Keypad Table
Lists the number of the keypad table that is loaded in the terminal.
80
Task Status
Shows the task name, stack, the percentage of time each subsystem has been running, and the stack usage.
86
Page Number
Running Diagnostics From the Menu System The TRAKKER Antares 2400 Menu System is a menu-driven application that lets you configure the terminal, view system information, and run diagnostics. You can access the TRAKKER Antares 2400 Menu System and run diagnostics while running any application.
Trakker Antares 2400 Family System Manual
69
Page 90
Chapter 4 - Running Diagnostics nugget
39 AGaramond
To run diagnostics from the TRAKKER Antares 2400 Menu System 1 Press ) ; 2 4 8 or scan this bar code: TRAKKER Antares 2400 Menu System
*..-.*
*..-.*
The Main Menu appears.
24XXS030.eps
2 Press † to choose the Diagnostics Menu and press ;. The Diagnostics Menu appears. DIAGNOSTICS MENU Software Diagnostics Hardware Diagnostics System Diagnostics
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 24XXS040.eps
The Diagnostics Menu contains these diagnostics:
70
Diagnostic Software Diagnostics
Description Lets you run software diagnostics to help analyze software problems on the terminal. For example, you can view the Error Logger file to view system errors.
Hardware Diagnostics
Lets you run hardware diagnostics to help analyze hardware problems on the terminal. For example, you can check the power remaining and the condition of the batteries.
System Diagnostics
Lets you run system diagnostics to help analyze network, system, or application problems on the terminal. For example, you can run diagnostics to check the communications between the 2455 and the access point.
Trakker Antares 2400 Family System Manual
Page 91
nugget
39 AGaramond Chapter 4 - Running Diagnostics
3 Press ¥ or † to choose Software Diagnostics, Hardware Diagnostics, or System Diagnostics and press ;. One of the diagnostics menus appears. SOFTWARE DIAGNOSTICS
HARDWARE DIAGNOSTICS
Error Logger Application Events Task Status Clear Task Profiles Font Test Keypad Table
Hardware Config Battery/PIC Status Display Test Keypad Test Main Board Menu Radio Test Scanner Test
MAIN BOARD MENU Application Beeper
SYSTEM DIAGNOSTICS Subsystem Versions Access Point App Efficiency Serial Port Test Malloc Info Menu Code Verify
MALLOC INFO Application Firmware
24XXS041.eps
Note: The Radio Test and Access Point diagnostics are only available for RF terminals. These diagnostics do not appear on terminals that do not have radios. 4 Press ¥ or † to choose the diagnostic test you want to run and press ;. The diagnostic screen appears. Use the information on the screen or follow the instructions to run the diagnostic test. For help, see the next section, “Defining the Diagnostics Screens.” 5 Press d to exit each diagnostic screen and to exit the diagnostics menus. 6 Choose another menu from the Main Menu or press d to exit the TRAKKER Antares 2400 Menu System. If you have made any changes, a screen prompts you to store the changes in flash memory. For help, see “Exiting the Menu System” in the configuration chapter of your user’s manual. After you exit the menu system, the terminal will resume the application you were running when you started the menu system.
Defining the Diagnostics Screens This section lists the diagnostics in alphabetical order. You can find the following information about each diagnostic test: • Description and purpose • Menu where the diagnostic is available • Sample diagnostic screen • Definition and explanation of the diagnostic screen To find diagnostics listed by category, see “What Diagnostics Are Available?” on page 68.
Trakker Antares 2400 Family System Manual
71
Page 92
Chapter 4 - Running Diagnostics nugget
39 AGaramond
Access Point Purpose: Use the Access Point screen to get version and address information about the access point the terminal is communicating with across the RF network. This diagnostic only applies to RF terminals. Where Available: System Diagnostics menu Sample Screen:
ACCESS POINT Radio ROM Ver: V1.6EB Radio MAC Addr: 0020A6306510 Access Point Name: SHIPPING Access Point MAC: 0020A6301365
[Esc] Exit 24XXS045.eps
Definition:
The screen displays the radio ROM firmware version and the radio MAC (machine) address for the terminal. It also displays the access point name and the access point MAC. If you have a problem with the radio or the connection to the access point, use the information on this screen to troubleshoot your network configuration.
Application Efficiency Purpose: Use the Application Efficiency screen to determine if your application is effectively using, and therefore maximizing, battery life on the terminal. Where Available: System Diagnostics menu Sample Screen:
APP EFFICIENCY Subsystem Versions Application is running at 90% 80% POOR
100% GOOD
Battery life is affected by application efficiency. [Esc] Exit 24XXS046.eps
Definition: The screen displays the application efficiency percentage. The closer the percentage is to 100%, the more efficient the application is at using battery power. When less power is required, the terminal automatically goes into an internal Standby mode to draw power at a lower level.
72
Trakker Antares 2400 Family System Manual
Page 93
nugget
39 AGaramond Chapter 4 - Running Diagnostics
An efficient application uses the Trakker Antares PSK (Programmer’s Software Kit) functions to wait for events to occur, and it does not poll in an infinite loop. When programmed correctly with the PSK or EZBuilder, the application uses the terminal’s battery power as efficiently as possible and does not prevent the terminal from going into Standby mode.
Application Events Purpose: A programmer can use the current status of each event to help debug applications running on the terminal. Where Available: Software Diagnostics menu. Sample Screen:
APPLICATION 0:0 1:0 2:0 3:0 4:0 5:0 6:0 7:0
EVENTS
COM1 RX SELECT COM2 RX SELECT RESERVED NET SELECT LABEL SELECT KEYBOARD SELECT COM3 RX SELECT
[Enter] Next [Esc] Exit screen
APPLICATION 8:0 9:0 10:0 11:0 12:0 13:0 14:0 15:0
EVENTS
NET TX SELECT TIME SELECT COM4 RX SELECT
[Enter] Next [Esc] Exit screen 24XXS047.eps
Definition: The terminal uses an event-driven architecture. All inputs to the terminal, such as from the keypad or from the network, arrive in the form of an event. You can check the status of each event using the Application Events screen. When an event is serviced by the application, the event is cleared. 0 means the event is cleared. 1 means the event has occurred (or is set).
Battery/PIC Status Purpose: Depending on the type of terminal you have, you can use the Battery/PIC status screens to get information about the terminal’s main (lithium-ion) battery pack, backup (NiCad) battery, or main board.
241X, 242X, and 243X Terminals Note: While the battery is charging, do not use this screen to determine when the battery is fully charged. To determine when the battery is fully charged, use the status LEDs on the battery chargers or communications dock. Where Available: Hardware Diagnostics menu, Battery/PIC Status, and then choose either Main Battery/PIC or Backup Battery/PIC.
Trakker Antares 2400 Family System Manual
73
Page 94
Chapter 4 - Running Diagnostics nugget
39 AGaramond
Note: The Backup Battery/PIC option is only available for the 242X terminal, because the 241X and 243X terminals do not have a backup battery. Sample Screen: BATTERY/PIC
MONITOR
Main Battery Capacity E
F 100%
Main
Battery
Volts
8.200V (Ea) Temp: 25C (A4) Main Charging: NO PIC Rev.:8 [Esc]
BATTERY/PIC
MONITOR
Backup Battery Good Backup Battery Volts 10.80V (BC) Temp:
25C
Backup
Charging:
PIC
Rev.:
[Esc]
(A4) NO
8
Exit
Exit 24XXS052.eps
Main Battery/PIC Screen
24XXS053.eps
Backup Battery/PIC Screen
Definition: The Main Battery/PIC screen displays the main battery capacity, the percentage of battery power remaining in the battery pack. You can continue using the battery pack until the terminal indicates that the battery is low: the Battery LED on your 241X turns on, the Battery icon on your 242X appears on the screen, or the Battery status icon on your 243X appears on the screen. Note: The 243X Battery status icon only appears if the status icons are enabled. For help enabling the status icons, see “Display Video Mode” on page 182. The Backup Battery/PIC screen indicates the status of the backup battery power, either GOOD or LOW. If the status is LOW, turn off the terminal. Let the main battery pack charge the backup battery. The backup battery fully charges in approximately 18 hours. You can also use these screens to find out the current volts, temperature, and charging status. For both screens, the PIC Rev field is the firmware version that is running on the battery monitory processor.
74
Trakker Antares 2400 Family System Manual
Page 95
39 AGaramond Chapter 4 - Running Diagnostics nugget
2455, 2475, and 248X Terminals Where Available: Hardware Diagnostics menu, Battery/PIC Status, and then choose either Main Battery/PIC or Backup Battery/PIC. Sample Screen:
BATTERY/PIC
MONITOR
Main Board Temp: -30C (00) IO Board Temp: -30C (00) EEPROM I2C
Checksum:
Mstr
Bus:
BATTERY/PIC
Temp:
25C
Backup
Charging:
Rev.:
[Esc]
(A4)
OK NO
OK PIC
PIC
MONITOR
Backup Battery Good Backup Battery Volts 10.80V (BC)
Rev.:
8
0
Exit
[Esc]
24XXS050.eps
Main Battery/PIC Screen
Exit
24XXS051.eps
Backup Battery/PIC Screen
Definition: The Main Battery/PIC screen does not provide information about the main battery because 2455, 2475, and 248X terminals do not have a main battery. Instead, this screen reports the temperature of the main board and the I/O board, as well as the status of the EEPROM checksum and the master bus. The Backup Battery/PIC screen displays the status of the backup battery. Battery Status Descriptions Status Good
Description The backup battery is operating correctly. No action is required.
Low
The backup battery needs to be charged. For help, see “Charging the Backup Battery” in Chapter 1 of the 2455, 2475, or 248X user’s manual.
Bad
The backup battery may be disconnected or not operating correctly. If you have a 2455, you can check if the backup battery is connected or replace it. For help, follow the instructions in “Replacing the Backup Battery” in Chapter 4 of the 2455 user’s manual. If you have a 2475 or 248X, contact your local Intermec service representative.
Note: The NiCad backup battery in the 2475 and 248X is not userserviceable. You must return the Trakker Antares 2475 or 248X terminal to Intermec to replace the backup battery.
Trakker Antares 2400 Family System Manual
75
Page 96
Chapter 4 - Running Diagnostics nugget
39 AGaramond
The Backup Battery/PIC screen also shows the current volts, temperature, and charging status. The number in parentheses after the volts and temperature is the hexadecimal value returned from the processor. On both screens, the PIC Rev field is the firmware version that is running on the battery monitory processor.
Beeper Test Purpose: You can test the terminal beeper to make sure the entire beep volume range and beep frequency range are available and working correctly. The Beeper Test can also help you distinguish the different beep volumes to choose a level that you can hear in your working environment. Where Available: Choose the Main Board Menu from the Hardware Diagnostics menu. Sample Screen:
BEEPER
TEST
SELECT BEEP TEST: (Hold down any key to stop test) 1-Frequency Test 2-Volume Test 3-Club 39 Jam 4-K. 622
[Esc]
Exit 24XXS056.eps
Definition: Press 1 to test the beep frequency range. The terminal will sound a series of beeps starting from a low frequency beep through the range to a high frequency beep, and then back to a low frequency beep. Press 2 to test the beep volume. The terminal sounds a series of beeps from a quiet beep to a very loud beep. Tests 3 and 4 also test the beep volume and frequency by playing a short tune. If you do not hear any beeps during any of these tests, you may have a problem with the beeper or internal speakers. For help, contact your local Intermec service representative.
Clear Task Profiles Purpose: Clears the task profile counters so that you can begin accumulating statistics on the firmware subsystem tasks from a known point in time. Where Available: Software Diagnostics menu
76
Trakker Antares 2400 Family System Manual