The text of a manual · part 13 of 38
Trakker Antares 2400 Family System Manual: Chapter 4 - Running Diagnostics, pages 107 to 114
Pages 107 to 114 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 107
nugget
39 AGaramond Chapter 4 - Running Diagnostics
Definition: The %Time field measures the relative amount of time that a given software task or component is active. For example, Idle Task (ID) in the Power Management software is a component. The %Time that Idle Task is active is directly proportional to battery life. The ID (idle) address should have the largest %Time field. If any other address (task) is large, you probably have a problem. You can also check the task list to determine the RF network protocol loaded on the terminal. Check the list of task names for UDP+, TCP/IP, or WTP. A task name of UDP+ means the terminal uses UDP Plus for RF communications. A task name of TCP/IP means the terminal uses TCP/IP for RF communications. A task name of WTP means the terminal uses WTP for RF communications. To refresh the statistics and start from a known point in time, use the Clear Task Profiles diagnostic option to clear the task status counters.
Error Numbers and Messages This table lists the error numbers that are posted to the second column on the Error Logger screen and lists the message associated with each number. You can use this information to help you interpret the errors logged for the terminal. To view the Error Logger screen, from the TRAKKER Antares 2400 Menu System, choose Diagnostics Menu, Software Diagnostics, and then Error Logger. Error Numbers and Messages Error Number
Message
Error Number
Message
0x01
Communications port in use
0x56
Incorrect parameter or string length
0x02
Transmission completed
0x57
Queue or pool empty
0x03
Transmission cancelled
0x58
Action not permitted from this origin
0x04
Communications error
0x59
Indicates that a DLE character has been found
0x10
Attempt to recover by auto suspend/resume
0x5A
During configuration parsing, a digit was expected
0x11
Card Change Detected
0x5B
Configuration item is invalid
0x12
Glitch in communications to radio
0x5F
Event out of sync with queue
0x51
Response larger than buffer
0x60
Queue is full
0x52
Reader command is invalid
0x61
UDP+: Buffer too large to send
0x53
Set attribute with bad value
0x62
UDP+: NULL buffer was passed
0x54
Write to read-only attribute
0x63
UDP+: Message received bigger than buffer
0x55
General error not covered
0x64
UDP+: Message already transmitted
Trakker Antares 2400 Family System Manual
87
Page 108
Chapter 4 - Running Diagnostics nugget
39 AGaramond
Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0x65
UDP+: Invalid parameter block
0x83
Data or ACK receive failed
0x66
Network not active or not configured properly
0x84
File write failed
0x67
NCB pointer is null
0x85
File close failed
0x68
Data pointer is null or data length invalid
0x86
Controller denied request
0x69
Network error
0x87
Network activate off
0x6A
Previous application message occupies send buffer
0x90
Card: unknown command to driver
0x6B
Network error
0x91
Card: invalid code
0x6C
Network error
0x92
Card: process response
0x6D
Network error
0x93
Card: offset too big
0x6E
Network error
0x94
Card: entry not in hash list
0x6F
An attempt was made to establish a new TCP connection
0x95
Card: security ID
0x70
The Ninit usnet call failed
0x110
No TCB slot available
0x71
The Nportinit usnet call failed
0x111
No RAM available for stack
0x72
The Nterm usnet call failed
0x112
Invalid time
0x73
The Portterm usnet call failed
0x113
Invalid slot
0x74
The Nopen usnet call failed
0x114
Invalid delay type
0x75
The Nclose usnet call failed
0x115
Invalid event
0x76
The Nread usnet call failed
0x116
Invalid group event
0x77
The Nwrite usnet call failed
0x117
Invalid resource
0x78
Invalid group event
0x118
Invalid mailbox
0x79
Network PM failed
0x119
Invalid memory release
0x7A
Invalid send buffer
0x11A
Function timeout expired
0x7B
The send buff is not empty
0x11B
Periodic event table full
0x7C
A failure occurred in UDP timer
0x11C
Invalid profile_type code
0x7D
Maximum number of bad sequence numbers has occurred. Possible duplicate IP address in network.
0x11D
Invalid MMU180 page number
0x7E
Could not connect to controller
0x11E
Device not open
0x7F
DHCP failed to obtain an IP address
0x11F
Device not open or not device owner
0x80
File open failed
0x120
Invalid pool ID
0x81
Read or write request failed
0x121
Invalid block size for pool
0x82
The getbuf usnet call failed
0x122
Invalid pool type
88
Trakker Antares 2400 Family System Manual
Page 109
nugget
39 AGaramond Chapter 4 - Running Diagnostics
Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0x123
No table space available for message
0x192
Invalid drive letter
0x134
Invalid file descriptor pointer
0x193
Duplicate file name
0x135
Task not suspended
0x194
Invalid file name
0x136
Not owner of stream
0x195
Directory full
0x137
Stream access error
0x196
Disk full
0x138
Color requested > NUMCOLORS
0x197
Invalid file control block
0x139
Missed system time required
0x198
Invalid seek mode
0x13A
Mtenv table full
0x199
Different drives
0x13B
Acquire/release table full
0x19A
End of file
0x13C
Too small of memory release to MTmeminit
0x19B
Drive table full
0x13D
Chkmem detects memory chain corrupt
0x19C
File system error
0x13E
MBXLIMIT messages in mailbox
0x19D
Invalid seek offset mode combination
0x13F
Too small of memory passed to MTmeminit
0x1D0
Application load error
0x140
Memory allocation error
0x1D1
Application load error
0x141
Null pointer passed to system call
0x1E0
Application load error
0x142
Error allocating label task resource
0x1E1
Application load error
0x143
Invalid task name string
0x1E2
No second flash chip, used by display
0x150
File transfer user abort
0x1F0
Add Decode - The Decode symbology is already present in the auto-discrimination table.
0x151
File transfer lost connection
0x1E2
No second flash chip, used by display
0x152
File transfer receiver canceled
0x1F1
Drop Decode - The Decode symbology was not found in the auto-discrimination table.
0x153
File transfer transmitter canceled
0x1F2
Intermediate row which was already read
0x154
File transfer bad protocol character
0x1F3
Intermediate row successfully decoded
0x180
File system type errors
0x1F4
Command symbology (Code 39)
0x181
File open error
0x1F5
Code39 half-ASCII
0x182
File write error
0x1F6
Good decode
0x183
File with no extension error
0x1F7
Label has already been read this trigger pull
0x184
Invalid file extension
0x1F8
Votes aren't all in for the label
0x185
Seek not permitted from Append mode
0x1F9
Get config character returned a quoted quote
0x186
Read not permitted in write only file
0x200
Decodes auto-discrimination table full
0x191
Duplicate drive letter
0x201
Decode Data command error: Not enough resources to attempt to decode the counts.
Trakker Antares 2400 Family System Manual
89
Page 110
Chapter 4 - Running Diagnostics nugget
39 AGaramond
Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0x202
Invalid Decodes command
0x21D
Raw scan buffer. No decode attempted yet
0x203
Invalid Decode symbology specified
0x21E
Error upgrading Flash on a Scanner Module
0x204
Unable to decode input scan
0x21E
Field is full no more input allowed until this is returned
0x205
Missing start or stop character
0x21F
Address not in the application data space range.
0x206
Number of counts less than minimum
0x221
Movement direction parameter invalid, not one of four viewport directions
0x207
Invalid character found
0x222
End of display block outside virtual display
0x208
Invalid acceleration between characters
0x223
A printable keycode was passed in a command to set manual movement
0x20A
Label length less than minimum
0x224
Both start and end outside of virtual display
0x20B
Incorrect check digit
0x225
First parameter to function invalid
0x20C
Output string too short
0x226
Invalid com source number i.e. > E_NET
0x20D
Leading margin not found
0x227
Input requested with no valid source to receive it from
0x20E
Invalid start or stop pattern
0x228
Start of display block outside virtual display
0x20F
Not enough counts for whole label
0x22A
PSK coding error
0x210
Missing trailing margin
0x22B
Network error
0x211
Invalid supplement to UPC label
0x22C
No description available
0x212
Parity error while decoding character
0x22D
Informational: Follow Cursor mode not enabled
0x213
Guard character not found
0x22E
The cursor detection value in a set follow cursor command is larger than the viewport size
0x214
Invalid row number (Code 49 or Code 16K)
0x230
The viewport movement value is larger than the viewport size
0x215
Unable to scale counts buffer
0x231
Data transmitted before cancel request accepted
0x216
Error in 2 of 5 label
0x241
Data entered does not match mask type
0x217
Wrong length 2 of 5 label
0x250
NMI for keypad received prior to vector
0x218
Longer than maximum 2 of 5 label length
0x251
NMI for PMU received prior to vector
0x219
Valid label region not found
0x260
SpOpen not previously called successfully
0x21A
Ink spread exceeded threshold
0x261
The port handle is unknown to CSP
0x21B
The denominator of an expression is 0
0x262
Control block pointer is NULL
0x21C
ASCIIfication of Full ASCII failed
0x263
Port is not valid
90
Trakker Antares 2400 Family System Manual
Page 111
nugget
39 AGaramond Chapter 4 - Running Diagnostics
Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0x264
Unknown mode
0x287
Modem returned error
0x265
Another CSP client has called SpOpen
0x288
Modem speed incorrect
0x266
Data pointer is NULL
0x289
Check modem speed
0x267
Frame mode configuration error
0x290
COM Port is not enabled in HW Config
0x268
SOM configured, but no EOM configured
0x300
Keypad 'HOT KEY' 0 has a NULL pointer to a far routine
0x269
SOM = EOM1 or SOM = EOM2, both invalid
0x301
Keypad 'HOT KEY' 1 has a NULL pointer to a far routine
0x26A
SOM, EOM1, or EOM2 set to invalid character (DLE, XON, XOFF)
0x302
Keypad 'HOT KEY' 2 has a NULL pointer to a far routine
0x26B
EOM1 = EOM2, invalid
0x303
Keypad 'HOT KEY' 3 has a NULL pointer to a far routine
0x26C
Suspend Resume cycle occurred.
0x304
Keypad 'HOT KEY' 4 has a NULL pointer to a far routine
0x26D
Protocol ran out of retries.
0x305
Keypad 'HOT KEY' 5 has a NULL pointer to a far routine
0x26E
Configuration change caused reset
0x306
Keypad 'HOT KEY' 6 has a NULL pointer to a far routine
0x26F
Receive error in packet
0x307
Keypad 'HOT KEY' 7 has a NULL pointer to a far routine
0x270
Library does not exist
0x308
Keypad 'HOT KEY' 8 has a NULL pointer to a far routine
0x271
BIN not in library
0x309
Keypad 'HOT KEY' 9 has a NULL pointer to a far routine
0x272
No relocatable BIN header
0x30A
Keypad 'HOT KEY' 10 has a NULL pointer to a far routine
0x273
PCMCIA card configuration failed
0x30B
Keypad 'HOT KEY' 11 has a NULL pointer to a far routine
0x280
Modem returned OK
0x30C
Keypad 'HOT KEY' 12 has a NULL pointer to a far routine
0x281
Modem operation failed
0x30D
Keypad 'HOT KEY' 13 has a NULL pointer to a far routine
0x282
No carrier detected
0x30E
Keypad 'HOT KEY' 14 has a NULL pointer to a far routine
0x283
No dial tone
0x30F
Keypad 'HOT KEY' 15 has a NULL pointer to a far routine
0x284
Line is busy
0x310
PIC interface error
0x26F
Receive error in packet
0x311
Battery value not valid due to charging
0x285
No answer
0x330
Unexpected interrupt
0x286
No CTS from modem
0x331
Divide by zero
Trakker Antares 2400 Family System Manual
91
Page 112
Chapter 4 - Running Diagnostics nugget
39 AGaramond
Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0x332
INT0 detected overflow exception
0x423D
Informational: returned due to tab key pressed
0x333
Array bounds exception
0x4240
Informational: returned due to escape key pressed
0x334
Unused opcode exception
0x4242
Informational: returned due to Up Arrow key pressed
0x335
Escape opcode exception
0x4243
Informational: returned due to Down Arrow key pressed
0x336
Unused int 7E subsystem
0x5220
Both row and column in viewport set XY invalid but adjusted to end
0x337
Check for powerdown
0x5229
Informational browse mode active
0x340
MultiDrop or Polling Mode D protocol error
0x522F
Attempted to cancel transmit buffer that was never called before
0x341
Bus error
0x5232
Viewporting is turned off-physical and virtual screens same size
0x342
Bus not available
0x523F
Informational: Viewport moved as far as possible hitting edge
0x343
Bus write acknowledge timeout
0xA1
Invalid sub-function request
0x344
XOFF prevents CSP TX
0xA2
Table is full
0x345
Reset from master interrupts CSP TX
0xA3
Index out of range
0x353
802.11b radio initialization failed. Cold boot or reset to recover.
0xA4
Time value at that index is zero
0x4233
Informational: returned due to function key 1 pressed
0xA5
Pointers do not match
0x4234
Informational: returned due to function key 2 pressed
0xA6
Requested row value not supported
0x4235
Informational: returned due to function key 3 pressed
0xA7
Requested column value not supported
0x4236
Informational: returned due to function key 4 pressed
0xA8
Invalid command
0x4237
Informational: returned due to function key 5 pressed
0xA9
Invalid configuration combination
0x4238
Informational: returned due to function key 6 pressed
0xAA
Invalid viewport request
0x4239
Informational: returned due to function key 7 pressed
0xAC
No description available
0x423A
Informational: returned due to function key 8 pressed
0xAD
Invalid logical key requested
0x423B
Informational: returned due to function key 9 pressed
0xAE
Invalid modifier requested
0x423C
Informational: returned due to function key 10 pressed
0xB0
Invalid device
92
Trakker Antares 2400 Family System Manual
Page 113
nugget
39 AGaramond Chapter 4 - Running Diagnostics
Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0xC0
IP format 0.x.x.x or 127.x.x.x
0xC3
Default router not on device network
0xC1
Controller and device IP same
0xC4
IP and Subnet invalid
0xC2
Default router and device IP same
0xC5
Configuration set timeout
This table lists the error numbers that are posted by the security code in the terminal and lists the message associated with each number. You can use this information to help you interpret the errors logged for the terminal. 802.1x Security Error Numbers and Messages Error Number
Message
Error Number
Message
0x0370
An encryption key with an invalid replay counter has been received and discarded.
0x037A
The 802.1x state machine on the terminal was unable to handle an event.
0x0371
An encryption key with an invalid key hash has been received and discarded.
0x037B
The 802.1x “Authenticating” state has timed out. A likely cause is a breakdown in the communications between the terminal and the authentication server.
0x0372
An encryption key with an unrecognized decode algorithm has been received and discarded.
0x037C
An error occurred while trying to send an EAP response. The output queue was full, so the response was not sent.
0x0374
A challenge for a security protocol that is not supported in the terminal was received and rejected.
0x037D
The application running on the terminal is not compatible with the authentication process.
0x0375
An error occurred while trying to send an Extensible Authentication Protocol (EAP) response. No buffer could be obtained, or the output queue was full, so the response was not sent.
0x037F
The root certificate exceeds the maximum size of 3K.
0x0376
An invalid or unrecognized Extensible Authentication Protocol (EAP)frame was received and discarded.
0x0509
The time and date on the terminal predates the range of valid dates for the server certificate.
0x0377
The authenticator rejected the terminal. The most likely cause is that the user name or password is incorrect.
0x050A
The time and date on the terminal postdates the range of valid dates for the server certificate.
0x0378
The CACERT.PEM file could not be loaded from drive C on the terminal. The file is either not on drive C, or it is too large.
0x0513
The root certificate authority certificate on the terminal cannot validate the server certificate. The server certificate is either invalid, improperly installed, or issued by a foreign certificate authority.
0x0379
The active application on the terminal cannot be successfully reloaded after authentication.
0x0518
There is a problem with the intermediate certificate authority. It cannot be used to validate the server certificate.
Trakker Antares 2400 Family System Manual
93
Page 114
Chapter 4 - Running Diagnostics nugget
39 AGaramond
802.1x Security Error Numbers and Messages (continued) Error Number
Message
Error Number
Message
0x0540
The root certificate authority certificate was not installed or is invalid.
0x0543
An unexpected error occurred while attempting to establish the TLS tunnel.
0x0541
No common name could be obtained from the server certificate.
0x0544
A login failure was received through the TLS tunnel.
0x0542
Neither of the RADIUS server names on the terminal match the name received in the server certificate.
94
Trakker Antares 2400 Family System Manual