Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 25

MaxiScan 2200 Reference Manual, pages 61 to 70

Pages 61 to 70 of 244

The original document is the PDF (753 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2200

Page 61

Configuration modes

Configuration modes Configuration authorization modes Configuration enable mode Configuration Enable Mode (*)

Configuration Enable Mode allows you to configure your MaxiScan 2200 at all times.

Configuration inhibit after 4 mn Configuration Inhibit After 4 mn protects the MaxiScan 2200 from unintentional configuration actions - configuration is inhibited if no configuration codes are read during the first 4 minutes after power-up. Each time a configuration code is read within 4 minutes, configuration is enabled for another 4 minutes. MaxiScan 2200 startup

4 mn 4 mn 4 mn configuration code configuration code configuration inhibit

Configuration Inhibit After 4 mn

MS/2200/RM/00/E/970131

51

Page 62

Configuration modes Temporary configuration mode Temporary Configuration Mode

Temporary Configuration Mode allows you to test new configuration settings without losing your current configuration setup. Temporary configuration mode remains active until you select Restore/Update Current Configuration or until you switch off the MaxiScan 2200.

Restore current configuration Restore Current Configuration quits temporary configuration mode and returns the MaxiScan 2200 to its current configuration settings.

Update current configuration Update Current Configuration replaces the current configuration settings with the new settings entered in temporary configuration mode. The MaxiScan 2200 quits temporary configuration mode.

Restore Current Configuration

52

Update Current Configuration

MS/2200/RM/00/E/970131

Page 63

Configuration modes Display data string mode Display Data String Mode allows you to display the data string values for configuration bar codes on a terminal screen. The configuration codes in this manual are in Code 128 format. Data string values are displayed in hexadecimal and are separated by backslashes or other characters depending on your terminal emulation setup. Data string values are useful if you want to concatenate configuration bar codes (Ð Concatenating configuration bar codes) or if you want to send commands directly from an RS-232 terminal to the MaxiScan 2200 in monitor mode (Ð RS-232 - Monitor mode). Display Data String Mode remains active until you switch off the MaxiScan 2200.

Example

1. Scan Display Data String Mode. 2. Read a configuration bar code - the Code 39 activation code (Ð Symbologies - Code 39 ) for example. The data string for Code 39 activation will be displayed on your terminal screen: \41\4C\60

Display Data String Mode

MS/2200/RM/00/E/970131

53

Page 64

Data decoding security parameters

Data decoding security parameters Description Data decoding security parameters allow you to ensure that the MaxiScan 2200 transmits the correct data after decoding, whatever the reading conditions or quality of the bar codes read. Predefined security levels

The Normal Security Level optimizes the reading speed for most situations. Only select Medium and High Security Levels when using poorquality bar codes or for critical applications. The predefined security level parameters can be individually.

modified

Increasing the level of security reduces the reading speed.

Data security and barcode length

The reliability of the barcode data transmitted can depend on the symbologies used - some symbologies are more "fragile" than others and errors may occur due to incorrect interpretation of code lengths. You can configure the MaxiScan 2200 to transmit data for codes of 1, 2 or 3 fixed lengths only or codes with a known minimum length (Ð Symbologies - Barcode length and data security). If you use the Compose Minimum Length option, we recommend that you use a check digit and the Consecutive same read data validation feature provided below to ensure that the same read result is obtained on 2 or more successive reads before the read is validated.

54

MS/2200/RM/00/E/970131

Page 65

Data decoding security parameters Predefined security levels Normal Security Level (*)

Normal security level Single Read Before Transmission - 500 ms Between Identical Consecutive Codes - 500 ms Between Different Consecutive Codes

Medium security level 2 Consecutive Same Reads Before Transmission - 500 ms Between Identical Consecutive Codes - 500 ms Between Different Consecutive Codes

High security level 3 Consecutive Same Reads Before Transmission - 500 ms Between Identical Consecutive Codes - 500 ms Between Different Consecutive Codes

Medium Security Level

MS/2200/RM/00/E/970131

High Security Level

55

Page 66

Data decoding security parameters Consecutive same read data validation Single Read Before Transmission (*)

Compose number of consecutive same reads before transmission Consecutive same read data validation is useful when increased data security is required - poorly printed codes, codes with variable lengths and without check digits, "fragile" barcode types. By default, transmission occurs after a single successful read. To increase the reliability of the data transmitted, you can set the MaxiScan 2200 to validate the data before transmission - it will only transmit data after a specified number of successful consecutive reads have given the same result. Increasing the number of consecutive same reads before transmission decreases the decoding rate.

Example

To make your MaxiScan 2200 read the same code successfully 5 times before it can transmit it: 1. Scan Compose Number of Consecutive Same Reads. 2. Scan 5 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).

Compose Number of Consecutive Same Reads Before Transmission (maximum = 255)

56

MS/2200/RM/00/E/970131

Page 67

Data decoding security parameters Timeout between identical consecutive codes 500 ms Between Identical Consecutive Codes (*)

Compose timeout between identical consecutive codes By default, you can only read identical consecutive codes after a timeout between reads of 500 ms. Increasing the timeout before you can read another identical code protects against unwanted reading of the same bar code. This timeout should not be shorter than the Timeout Between Different Consecutive Codes.

Example

To make your MaxiScan 2200 wait 1 second (= 1000 ms) before it can read the same code again: 1. Scan Compose Timeout Between Identical Consecutive Codes. 2. Scan 1 0 0 0 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).

Compose Timeout Between Identical Consecutive Codes (maximum timeout = 65 535 ms)

MS/2200/RM/00/E/970131

57

Page 68

Data decoding security parameters Timeout between different consecutive codes 500 ms Between Different Consecutive Codes (*)

Compose timeout between different consecutive codes By default, you can only read different consecutive codes after a timeout between reads of 500 ms. Increasing the timeout before you can read a different code protects against unwanted reading of other bar codes if they are close together on the same label. This timeout should not be longer than the Timeout Between Identical Consecutive Codes.

Example

To make your MaxiScan 2200 wait 1 second (= 1000 ms) before it can read a different code: 1. Scan Compose Timeout Between Different Consecutive Codes. 2. Scan 1 0 0 0 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).

Compose Timeout Between Different Consecutive Codes (maximum timeout = 65 535 ms)

58

MS/2200/RM/00/E/970131

Page 69

Default parameter settings

Default parameter settings Factory default settings for the MaxiScan 2200 configuration parameters are indicated by “*” in this manual. Use the Reset Factory Defaults code to reset all the MaxiScan 2200 parameters to their factory default settings (Ð Reset all configuration parameters ). Ð Parameter list / data strings provides the full list of parameters including default settings.

MS/2200/RM/00/E/970131

59

Page 70

Error messages

Error messages Display EEPROM Error Messages

The MaxiScan 2200 stores operating error messages in an internal EEPROM. Display EEPROM Error Messages displays these messages on the host terminal screen if applicable (keyboard wedge, RS-232 C and RS-232 TTL). Delete EEPROM Error Messages clears the messages currently stored in the EEPROM.

Delete EEPROM Error Messages

60

MS/2200/RM/00/E/970131