Page 51

Code mark

Code mark Code mark activation Code Mark Not Transmitted (*)

Transmit Code Mark enables transmission of current settings of code marks - barcode symbology identifying characters - for all the symbologies supported. Transmit Code Mark + Barcode Length transmits 2 decimal digits after the code mark to indicate the length of the code read. Code marks are transmitted after the preamble if present and before the barcode data.

M Code marks should only be activated for keyboard wedge and RS-232 interfaces.

Transmit Code Mark

MS/2200/RM/00/E/970131

Transmit Code Mark + Barcode Length

41

Page 52

Code mark Default code mark values - Keyboard wedge and RS-232 interfaces Use the Compose Code Mark codes on the next pages to modify the default code marks

M Code marks should only be modified for keyboard wedge and RS-232 interfaces. symbology

42 default code mark

Codabar

N

Code 39

M

Code 128 / EAN 128

M

Interleaved 2 of 5

I

Matrix 2 of 5

?

Standard 2 of 5

H

MSI Code

M

Plessey Code

M

UPC-A

A

UPC-E

E

EAN-8

FF

EAN-13

F

MS/2200/RM/00/E/970131

Page 53

Code mark Composing custom code marks Codabar - Compose Code Mark

Code 39 - Compose Code Mark

1. Select the Compose Code Mark code for your symbology. 2. Scan an identifying character and scan End Selection to finish (Ð ASCII character codes).

M Compose code marks for keyboard wedge and RS-232 interfaces only.

Code 128 / EAN 128 - Compose Code Mark

MS/2200/RM/00/E/970131

43

Page 54

Code mark UPC-A - Compose Code Mark

UPC-E - Compose Code Mark

EAN-8 - Compose Code Mark

EAN-13 - Compose Code Mark

44

MS/2200/RM/00/E/970131

Page 55

Code mark Interleaved 2 of 5 - Compose Code Mark

Matrix 2 of 5 - Compose Code Mark

Standard 2 of 5 - Compose Code Mark

MS/2200/RM/00/E/970131

45

Page 56

Code mark MSI Code - Compose Code Mark

Plessey Code - Compose Code Mark

46

MS/2200/RM/00/E/970131

Page 57

Compose interface number

Compose interface number Which interface number? To know which interface number to enter, check the following points in the order shown: 1. Look to see if there is a suitable number in the Predefined interface numbers section for your interface. 2. Look to see if your configuration is described in the MaxiScan 2200 Terminal List (if available). 3. If you still do not know which number to enter, contact your UBI representative.

MS/2200/RM/00/E/970131

47

Page 58

Compose interface number Composing an interface number Entering an interface number usually only modifies data transmission parameter settings but in some special cases, other parameter settings (beep settings, symbologies, etc.) may be modified for specific interface configurations. The MaxiScan 2200 will only accept interface numbers that are compatible with its hardware configuration (I/O board and cable) - if you try to enter a number for a different interface, you will hear 6 error beeps. If necessary, check the interface of your MaxiScan 2200 model (ÐInterfaces ).

Example

To enter the number 102: 1. Scan Compose Interface Number on the next page. 2. Scan each digit of your interface number using the number codes - in our example we would scan 1, then 0, then 2 - and scan End Selection to finish (Ð Number codes or appendix at the end of this manual)

Compose Interface Number

48

MS/2200/RM/00/E/970131

Page 59

Concatenating configuration bar codes

Concatenating configuration bar codes What is a configuration bar code? All the configuration codes in this Reference Manual are Code 128 bar codes with a special terminator character - FNC3, data string \60 - to indicate that the code is a configuration code.

Why concatenate? In order to configure the MaxiScan 2200 for a given installation, you may need to read a number of configuration codes one after the other - and you may need to do this for each MaxiScan 2200 you have to install and set up. Many of the configuration bar codes in this manual can be concatenated (combined) to form a single custom bar code which corresponds to your own particular setup configuration - you then only need to read 1 or 2 concatenated codes instead of a whole series of codes.

Limitations Do not create concatenated codes wider than the maximum reading width of your MaxiScan 2200 product - approximately 20 cm (8"). If you need to create more than one code for a series of configuration codes, always end each concatenated code with a complete configuration code - not a partial code - and the FNC3 terminator. You can not concatenate configuration codes that use the Number codes to compose numerical values.

How to concatenate 1. Identify the list of codes you want to concatenate and the order of concatenation - the codes should be concatenated in the same order as you would read them individually.

MS/2200/RM/00/E/970131

49

Page 60

Concatenating configuration bar codes Example

If you need to enter Reset Factory Defaults, put this code at the beginning.

2. Obtain the data strings for the codes you want to concatenate (Ð Parameter list / data strings). Example

For the following codes, you will obtain the following strings: reset factory defaults

\46\42\60

N° 100 - Standard RS-232 C (9600, 7, E, 2)

\41\4A\01\24\60

Codabar active

\41\52\60

2 good read beeps

\45\4A\01\60

You can also obtain the data strings by putting the MaxiScan 2200 into Display Data String mode and reading the configuration codes of your choice (Ð Configuration modes - Display data strings). However, the strings displayed include a check digit after the \60 end-of-code character which you must also remove when you concatenate the codes.

3. Use the individual data strings to create a single data string and remove the \60 end-of-code characters for each code except the last code in the string. Example

For the codes listed in the previous example, you will obtain the following concatenated string: \46\42\41\4A\01\24\41\52\45\4A\01\60

4. If necessary, convert the hexadecimal values and backslash separators into suitable values for your barcode printing sofware (ASCII values for example). The data strings contain hexadecimal values separated by backslashes. Make sure that the values you use with your software correspond to these values. Example: Instead of the hexadecimal value \41, you may need to use the equivalent ASCII character "A" (do not use the decimal value 41 !).

50

MS/2200/RM/00/E/970131