Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 25

MaxiScan 2200 Reference Manual, pages 71 to 80

Pages 71 to 80 of 244

The original document is the PDF (753 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2200

Page 71

Glossary

Glossary data transmission parameters interface-specific communication parameters - in certain cases they need to be modified to optimize the performance of the MaxiScan 2200 dual RS-232 C

MaxiScan 2200 connected between two systems communicating through an RS-232 link (external power supply necessary)

external power supply

6V mains power supply adapter - necessary if the host system does not provide enough electrical power to drive the MaxiScan 2200 interface number automatically configures your MaxiScan 2200 by setting interfacespecific parameters - in particular data transmission parameters - to suit your operating environment keyboard wedge

MaxiScan 2200 connected between a keyboard and the host system - data from the MaxiScan 2200 is transmitted in keyboard emulation mode to provide instant software compatibility (external power supply necessary)

operating parameters parameters that affect the way the MaxiScan 2200 operates - general operating parameters include resolution adjustment (video channel selection), depth of field, scan rate, standby mode settings, beep characteristics symbology bar code type or "family" - Code 39, UPC and EAN are examples of common symbologies

MS/2200/RM/00/E/970131

61

Page 72

IBM 46xx cash registers

IBM 46xx cash registers Connection port 5x or 9x

Ø

IBM 46xx cable

1. Switch off the host system. 2. Use the IBM 46xx cable to connect the MaxiScan 2200 to the host system.

62

MS/2200/RM/00/E/970131

Page 73

IBM 46xx cash registers Predefined interface numbers N° 110 - IBM 46xx cash registers - Port 9x

If your interface number is not among the predefined interface numbers, you must compose the number yourself (Ð Compose interface number ). The orange indicator LED of MaxiScan 2200 models configured for IBM cash registers will flash 3 times at power-up. Configuration is independent of the physical link with the cash register - you can configure the MaxiScan 2200 for Port 9x or Port 5x as required by the host system.

N° 111 - IBM 46xx cash registers - Port 5x

MS/2200/RM/00/E/970131

63

Page 74

IBM 46xx cash registers Predefined data transmission settings Predefined settings for IBM 46xx cash registers - Interface N° 110 / N° 111 The main predefined parameter settings for IBM 46xx cash registers depend on cash register protocols and can not be modified.

Transmission delay Ð Inter-message delay

64

MS/2200/RM/00/E/970131

Page 75

Installation procedure

Installation procedure The MaxiScan 2200 Installation Guide tells you step by step how to install and set up your MaxiScan 2200 to operate successfully in most working situations.

General installation / configuration procedure 1. Check you have everything you need (Ð Product checklist). 2. Switch off the host system and connect up your MaxiScan 2200 (Ð Connection for your interface). 3. Switch on the host system. 4. Scan the interface number for your system (Ð Predefined interface numbers for your interface or Compose interface number). 5. Customize the data transmission settings for your interface if required (Ð Data transmission parameters for your interface). 6. Select the symbologies you need and customize the symbology parameter settings if required (Ð Symbologies). 7. Customize the MaxiScan 2200 operating settings if required (Ð Parameter list / data strings and individual operating parameter entries).

MS/2200/RM/00/E/970131

65

Page 76

Inter-character delay

Inter-character delay No Delay (*)

10 ms

The maximum rate at which data can be transmitted by the MaxiScan 2200 is affected by the response of the system. By the insertion of an inter-character delay, the MaxiScan 2200 can avoid dropping characters if it is transmitting decoded data too rapidly. Select one of the predefined values or compose a custom value. This feature can only be used with keyboard wedge and RS-232 interfaces and OCIA cash registers.

20 ms

66

30 ms

MS/2200/RM/00/E/970131

Page 77

Inter-character delay 40 ms

50 ms

Compose inter-character delay Example

To make your MaxiScan 2200 insert an 80 ms delay between characters: 1. Scan Compose Inter-Character Delay. 2. Scan 8 0 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).

Compose Inter-Character Delay (maximum = 999 ms)

MS/2200/RM/00/E/970131

67

Page 78

Inter-message delay

Inter-message delay No Delay (*)

10 ms

The maximum rate at which data can be transmitted by the MaxiScan 2200 is affected by the response of the system. By the insertion of an inter-message delay, the MaxiScan 2200 can avoid dropping characters if it is transmitting decoded data too rapidly. Select one of the predefined values or compose a custom value. This feature can be used with all interfaces.

30 ms

68

50 ms

MS/2200/RM/00/E/970131

Page 79

Inter-message delay 80 ms

100 ms

Compose inter-message delay Example

To make your MaxiScan 2200 insert a 200 ms delay between messages: 1. Scan Compose Inter- Message Delay. 2. Scan 2 0 0 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).

Compose Inter-Message Delay (maximum = 999 ms)

MS/2200/RM/00/E/970131

69

Page 80

Interfaces

Interfaces Identifying the interface The indicator LED flashes orange a number of times at power-up to indicate the interface configuration of your MaxiScan 2200 model. If the MaxiScan 2200 has already been programmed for a given interface configuration, the indicator LED will stay green. If no interface number has been programmed - which may be the case during first-time setup or after reading the Reset Factory Defaults code - the indicator LED will stay orange and you will have to re-enter the appropriate interface number for your system (ÐPredefined interface numbers section for your interface or Compose interface number ). red power-up LED orange LED flashes

70 green / orange indicator LED interface configuration

2 flashes

RS-232 C dual RS-232 C

3 flashes

IBM 46xx cash registers

4 flashes

RS-232 TTL wand emulation

5 flashes

OCIA cash registers

7 flashes keyboard wedge

MS/2200/RM/00/E/970131