Page 181
Symbologies - Activation UPC-A Deactivated
UPC-E Deactivated
EAN-8 Deactivated
EAN-13 Deactivated
MS/2200/RM/00/E/970131
171
Page 182
Symbologies - Codabar
Symbologies - Codabar Activation Not Active (*)
Active
Default values Start/stop
-
Not Transmitted
CLSI library system
-
Not Active
Check digit (AIM recommendation)
-
Not Used
Number of characters
-
Minimum Length = 6
Start/stop Not Transmitted (*)
172
MS/2200/RM/00/E/970131
Page 183
Symbologies - Codabar Start/stop a, b, c, d a, b, c, d
A, B, C, D
/ t, n, *, e
MS/2200/RM/00/E/970131
DC1, DC2, DC3, DC4
173
Page 184
Symbologies - Codabar CLSI library system Not Active (*)
Libraries in the CLSI system used in the United States require the insertion of spaces after characters 1, 5 and 10 in the 14-character label. Example 39990000192148 is transmitted as:
3 9990 00019 2148
CLSI With Spaces inserts the spaces and activates automatic barcode reconstruction to increase decoding efficiency. CLSI Without Spaces does not insert spaces but activates automatic barcode reconstruction for CLSI codes. The start/stop code can be transmitted or not transmitted as required.
CLSI With Spaces
174
CLSI Without Spaces
MS/2200/RM/00/E/970131
Page 185
Symbologies - Codabar Check digit (AIM recommendation) Not Used (*)
While Codabar has no check character, AIM has a recommended character. Each Codabar data character has a value assigned to it.
Checked And Transmitted
Checked But Not Transmitted
MS/2200/RM/00/E/970131
175
Page 186
Symbologies - Codabar AIM data character values data character value data character value
0 1 2 3 4 5 6 7 8 9
0 1 2 3 4 5 6 7 8 9
$ : / , + A B C D
10 11 12 13 14 15 16 17 18 19
Calculation of the check digit
1. The values corresponding to all the Codabar data characters in the message (including Start/Stop characters) are added together to make a total. 2. The data character which must be added to this total to make a multiple of 16 is the check character. Example
176 message:
A01234B characters:
A 0 1 2 3 4 B values:
16 0 1 2 3 4 17 sum of character values:
43 next multiple of 16:
48
48 - 43 =
5 (the check character)
final message:
A012345B
MS/2200/RM/00/E/970131
Page 187
Symbologies - Codabar Barcode length Minimum Length = 6 (*)
Return To Current Minimum Length
Barcode length (number of characters) for Codabar = [start + barcode data + check digit if applicable + stop]. The minimum length possible is 3 characters. If you scan Compose 1 Or 2 Or 3 Fixed Lengths or Compose Minimum Length, use the special number codes (Ð Number codes or appendix at the end of this manual) or the ASCII character codes (Ð ASCII character codes ) to enter the barcode lengths. Compose 1 Or 2 Or 3 Fixed Lengths provides the most security if the codes in your application have fixed lengths: • if you use the number codes, scan End Selection after each length and scan End Selection a second time when you have finished (after 1, 2 or 3 fixed lengths),
• if you use the ASCII codes, do not scan End Selection until you have finished entering all the lengths (after 1, 2 or 3 fixed lengths).
Compose Minimum Length provides a certain degree of security if you know the minimum length of the codes in your application - enter the minimum length (number codes or ASCII code) and scan End Selection to finish. Return To Current Minimum Length cancels any fixed length settings.
Compose Minimum Length
Compose 1 Or 2 Or 3 Fixed Lengths
MS/2200/RM/00/E/970131
177
Page 188
Symbologies - Code 39 (*)
Symbologies - Code 39 (*) Activation Active (*)
Not Active
Select the desired Code 39 format if required (Standard 43 Characters or Full ASCII) and scan Active to enable. Full ASCII characters are encoded using one of the four control characters ($, %, /, +) in combination with a letter (Ð Full ASCII conversion chart - Code 39 on the next page).
Default values Code 39 format
-
Standard 43 Characters
Start/stop
-
Not Transmitted
Check digit
-
Not Used
Number of characters
-
Minimum Length = 6
Code 39 format Standard 43 Characters (*)
178
Full ASCII
MS/2200/RM/00/E/970131
Page 189
Symbologies - Code 39 (*) Full ASCII conversion chart - Code 39 Code 39 ASCII
Hex Code 39 ASCII
Hex Code 39 ASCII
Hex Code 39 ASCII
Hex
%U
NUL
00
Space
SP
20
%V
@
40
%W
‘
60
$A
SOH
01
/A
!
21
A
A
41
+A a
61
$B
STX
02
/B
"
22
B
B
42
+B b
62
$C
ETX
03
/C
#
23
C
C
43
+C c
63
$D
EOT
04
$
$
24
D
D
44
+D d
64
$E
ENQ
05
%
%
25
E
E
45
+E e
65
$F
ACK
06
/F
&
26
F
F
46
+F f
66
$G
BEL
07
/G
’
27
G
G
47
+G g
67
$H
BS
08
/H
(
28
H
H
48
+H h
68
$I
HT
09
/I
)
29
I
I
49
+I i
69
$J
LF
0A
/J
*
2A
J
J
4A
+J j
6A
$K
VT
0B
+
+
2B
K
K
4B
+K k
6B
$L
FF
0C
/L
,
2C
L
L
4C
+L l
6C
$M
CR
0D
/M
-
2D
M
M
4D
+M m
6D
$N
SO
0E
/N
.
2E
N
N
4E
+N n
6E
$O
SI
0F
/
/
2F
O
O
4F
+O o
6F
$P
DLE
10
0
0
30
P
P
50
+P p
70
$Q
DC1
11
1
1
31
Q
Q
51
+Q q
71
$R
DC2
12
2
2
32
R
R
52
+R r
72
$S
DC3
13
3
3
33
S
S
45
+S s
73
$T
DC4
14
4
4
34
T
T
54
+T t
74
$U
NAK
15
5
5
35
U
U
55
+U u
75
$V
SYN
16
6
6
36
V
V
56
+V v
76
$W
ETB
17
7
7
37
W
W
57
+W w
77
$X
CAN
18
8
8
38
X
X
58
+X x
78
$Y
EM
19
9
9
39
Y
Y
59
+Y y
79
$Z
SUB
1A
/Z
:
3A
Z
Z
5A
+Z z
7A
%A
ESC
1B
%F
;
3B
%K
[
5B
%P
{
7B
%B
FS
1C
%G
<
3C
%L
\
5C
%Q
|
7C
%C
GS
1D
%H
=
3D
%M
]
5D
%R
}
7D
%D
RS
1E
%I
>
3E
%N
^
5E
%S
~
7E
%E
US
1F
%J
?
3F
%O
_
5F
%T
DEL
7F
MS/2200/RM/00/E/970131
179
Page 190
Symbologies - Code 39 (*) Start/stop Transmission Not Transmitted (*)
Transmitted
180