Page 181

Symbologies - Activation UPC-A Deactivated

UPC-E Deactivated

EAN-8 Deactivated

EAN-13 Deactivated

MS/2200/RM/00/E/970131

171

Page 182

Symbologies - Codabar

Symbologies - Codabar Activation Not Active (*)

Active

Default values Start/stop

-

Not Transmitted

CLSI library system

-

Not Active

Check digit (AIM recommendation)

-

Not Used

Number of characters

-

Minimum Length = 6

Start/stop Not Transmitted (*)

172

MS/2200/RM/00/E/970131

Page 183

Symbologies - Codabar Start/stop a, b, c, d a, b, c, d

A, B, C, D

/ t, n, *, e

MS/2200/RM/00/E/970131

DC1, DC2, DC3, DC4

173

Page 184

Symbologies - Codabar CLSI library system Not Active (*)

Libraries in the CLSI system used in the United States require the insertion of spaces after characters 1, 5 and 10 in the 14-character label. Example 39990000192148 is transmitted as:

3 9990 00019 2148

CLSI With Spaces inserts the spaces and activates automatic barcode reconstruction to increase decoding efficiency. CLSI Without Spaces does not insert spaces but activates automatic barcode reconstruction for CLSI codes. The start/stop code can be transmitted or not transmitted as required.

CLSI With Spaces

174

CLSI Without Spaces

MS/2200/RM/00/E/970131

Page 185

Symbologies - Codabar Check digit (AIM recommendation) Not Used (*)

While Codabar has no check character, AIM has a recommended character. Each Codabar data character has a value assigned to it.

Checked And Transmitted

Checked But Not Transmitted

MS/2200/RM/00/E/970131

175

Page 186

Symbologies - Codabar AIM data character values data character value data character value

0 1 2 3 4 5 6 7 8 9

0 1 2 3 4 5 6 7 8 9

$ : / , + A B C D

10 11 12 13 14 15 16 17 18 19

Calculation of the check digit

1. The values corresponding to all the Codabar data characters in the message (including Start/Stop characters) are added together to make a total. 2. The data character which must be added to this total to make a multiple of 16 is the check character. Example

176 message:

A01234B characters:

A 0 1 2 3 4 B values:

16 0 1 2 3 4 17 sum of character values:

43 next multiple of 16:

48

48 - 43 =

5 (the check character)

final message:

A012345B

MS/2200/RM/00/E/970131

Page 187

Symbologies - Codabar Barcode length Minimum Length = 6 (*)

Return To Current Minimum Length

Barcode length (number of characters) for Codabar = [start + barcode data + check digit if applicable + stop]. The minimum length possible is 3 characters. If you scan Compose 1 Or 2 Or 3 Fixed Lengths or Compose Minimum Length, use the special number codes (Ð Number codes or appendix at the end of this manual) or the ASCII character codes (Ð ASCII character codes ) to enter the barcode lengths. Compose 1 Or 2 Or 3 Fixed Lengths provides the most security if the codes in your application have fixed lengths: • if you use the number codes, scan End Selection after each length and scan End Selection a second time when you have finished (after 1, 2 or 3 fixed lengths),

• if you use the ASCII codes, do not scan End Selection until you have finished entering all the lengths (after 1, 2 or 3 fixed lengths).

Compose Minimum Length provides a certain degree of security if you know the minimum length of the codes in your application - enter the minimum length (number codes or ASCII code) and scan End Selection to finish. Return To Current Minimum Length cancels any fixed length settings.

Compose Minimum Length

Compose 1 Or 2 Or 3 Fixed Lengths

MS/2200/RM/00/E/970131

177

Page 188

Symbologies - Code 39 (*)

Symbologies - Code 39 (*) Activation Active (*)

Not Active

Select the desired Code 39 format if required (Standard 43 Characters or Full ASCII) and scan Active to enable. Full ASCII characters are encoded using one of the four control characters ($, %, /, +) in combination with a letter (Ð Full ASCII conversion chart - Code 39 on the next page).

Default values Code 39 format

-

Standard 43 Characters

Start/stop

-

Not Transmitted

Check digit

-

Not Used

Number of characters

-

Minimum Length = 6

Code 39 format Standard 43 Characters (*)

178

Full ASCII

MS/2200/RM/00/E/970131

Page 189

Symbologies - Code 39 (*) Full ASCII conversion chart - Code 39 Code 39 ASCII

Hex Code 39 ASCII

Hex Code 39 ASCII

Hex Code 39 ASCII

Hex

%U

NUL

00

Space

SP

20

%V

@

40

%W

‘

60

$A

SOH

01

/A

!

21

A

A

41

+A a

61

$B

STX

02

/B

"

22

B

B

42

+B b

62

$C

ETX

03

/C

#

23

C

C

43

+C c

63

$D

EOT

04

$

$

24

D

D

44

+D d

64

$E

ENQ

05

%

%

25

E

E

45

+E e

65

$F

ACK

06

/F

&

26

F

F

46

+F f

66

$G

BEL

07

/G

’

27

G

G

47

+G g

67

$H

BS

08

/H

(

28

H

H

48

+H h

68

$I

HT

09

/I

)

29

I

I

49

+I i

69

$J

LF

0A

/J

*

2A

J

J

4A

+J j

6A

$K

VT

0B

+

+

2B

K

K

4B

+K k

6B

$L

FF

0C

/L

,

2C

L

L

4C

+L l

6C

$M

CR

0D

/M

-

2D

M

M

4D

+M m

6D

$N

SO

0E

/N

.

2E

N

N

4E

+N n

6E

$O

SI

0F

/

/

2F

O

O

4F

+O o

6F

$P

DLE

10

0

0

30

P

P

50

+P p

70

$Q

DC1

11

1

1

31

Q

Q

51

+Q q

71

$R

DC2

12

2

2

32

R

R

52

+R r

72

$S

DC3

13

3

3

33

S

S

45

+S s

73

$T

DC4

14

4

4

34

T

T

54

+T t

74

$U

NAK

15

5

5

35

U

U

55

+U u

75

$V

SYN

16

6

6

36

V

V

56

+V v

76

$W

ETB

17

7

7

37

W

W

57

+W w

77

$X

CAN

18

8

8

38

X

X

58

+X x

78

$Y

EM

19

9

9

39

Y

Y

59

+Y y

79

$Z

SUB

1A

/Z

:

3A

Z

Z

5A

+Z z

7A

%A

ESC

1B

%F

;

3B

%K

[

5B

%P

{

7B

%B

FS

1C

%G

<

3C

%L

\

5C

%Q

|

7C

%C

GS

1D

%H

=

3D

%M

]

5D

%R

}

7D

%D

RS

1E

%I

>

3E

%N

^

5E

%S

~

7E

%E

US

1F

%J

?

3F

%O

_

5F

%T

DEL

7F

MS/2200/RM/00/E/970131

179

Page 190

Symbologies - Code 39 (*) Start/stop Transmission Not Transmitted (*)

Transmitted

180

MS/2200/RM/00/E/970131