Page 171

Standby mode Default standby settings Initial Standby After 15 Minutes (*)

Default values before standby: • initial standby: the laser beam is switched off after T = 15 minutes (900 seconds),

• full standby: the rotating mirror motor is switched off after an additional period of T x 2 = 30 minutes and a total period of inactivity of T x 3 = 45 minutes.

Composing a different time before standby Example

To change the time before initial standby to 10 minutes (600 seconds): 1. Scan Compose Time In Seconds Before Initial Standby. 2. Scan 6 0 0 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual). The MaxiScan 2200 will go into initial standby after 10 minutes and full standby after a total of 30 minutes after the last read attempt.

Compose Time In Seconds Before Initial Standby

MS/2200/RM/00/E/970131

161

Page 172

Symbologies

Symbologies Available symbologies To optimize the performance of your MaxiScan 2200 and to ensure trouble-free scanning, do not select symbologies that you do not need. If possible, do not select more than 2 symbologies at the same time - deactivate the Code 39 and UPC/EAN default symbologies if you do not need to use them. Ð Symbologies - Codabar Ð Symbologies - Code 39 (*) Ð Symbologies - Code 128 / EAN 128 Ð Symbologies - Interleaved 2 of 5 Ð Symbologies - Matrix 2 of 5 Ð Symbologies - MSI Code Ð Symbologies - Plessey Code Ð Symbologies - Standard 2 of 5 Ð Symbologies - UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) (*)

Default symbologies Code 39 and the UPC/EAN code families are preselected by default. When you install and set up your MaxiScan 2200 for the first time, all the symbology parameters are set to their factory default settings - indicated by an asterisk (*) in this manual. The symbology default settings are global factory defaults - they are independent of the different symbology activation codes. If you want to reset all the default symbology settings, you can scan the Reset Factory Defaults bar code (Ð Reset all configuration parameters), but you will then have to completely reconfigure your MaxiScan 2200. It is often easier to scan Disable All Symbologies and reactivate individual symbologies ( Ð Symbologies - Activation ).

162

MS/2200/RM/00/E/970131

Page 173

Symbologies Character formats and MaxiScan 2200 transmission format symbology character format supported

MaxiScan 2200 transmission format

•

Code 39 alphanumeric - letter case not defined upper case

•

Code 128 alphanumeric full ASCII - letter case defined full ASCII - lower case/upper case as defined

• • • • •

Codabar Interleaved 2 of 5 Matrix 2 of 5, Standard 2 of 5 UPC/EAN code set numerical numerical

MS/2200/RM/00/E/970131

163

Page 174

Symbologies Barcode length and data security As well as barcode length parameters, other configuration parameters help to increase the security of the data transmitted ( Ð Data decoding security parameters ).

The reliability of the barcode data transmitted can depend on the symbologies used - some symbologies are more "fragile" than others and errors may occur due to incorrect interpretation of code lengths. Depending on the symbology used, the following barcode length parameters allow you to configure the MaxiScan 2200 to only accept codes which meet certain length requirements: •

Compose 1 Or 2 Or 3 Fixed Lengths - the safest option if you know that all the codes in your application have fixed lengths,

•

Compose Minimum Length - if there are variable code lengths but you know that there is a minimum length.

All symbologies except UPC/EAN are set to a minimum code length of 6 characters by default. You can use the special number codes (Ð Number codes or appendix at the end of this manual) or the ASCII character codes (Ð ASCII character codes) to enter the barcode lengths. If you use the Compose Minimum Length option, we recommend that you use a check digit (if available) and the Consecutive same read data validation feature (Ð Data decoding security parameters) to ensure that the same read result is obtained on 2 or more successive reads before the read is validated.

M Each symbology has its own set of configuration codes for barcode length parameters - you must only use the codes for your symbology.

164

MS/2200/RM/00/E/970131

Page 175

Symbologies - Activation

Symbologies - Activation To optimize the performance of your MaxiScan 2200 and to ensure trouble-free scanning, do not select symbologies that you do not need. If possible, do not select more than 2 symbologies at the same time - deactivate the Code 39 and UPC/EAN default symbologies if you do not need to use them. The symbology activation codes are also provided with the parameters for each symbology (Ð appropriate Symbologies section for your symbology).

Disable All Symbologies Disable All Symbologies deactivates all the symbologies activated. If you want to deactivate individual symbologies, use the Not Active codes for each symbology. Disable All Symbologies does not reset the individual parameter settings for each symbology. When you reactivate a symbology, you recover the parameter settings stored in memory for that symbology when it was disabled. If you want to reset all the symbology parameters to their factory default values, you must scan the Reset Factory Defaults bar code ( Ð Reset all configuration parameters ). Disable All Symbologies

MS/2200/RM/00/E/970131

165

Page 176

Symbologies - Activation Symbology activation codes Codabar - Not Active (*)

Codabar - Active

The default format for Code 39 is Standard 43 Characters. Code 39 - Not Active

166

Code 39 - Active (*)

MS/2200/RM/00/E/970131

Page 177

Symbologies - Activation Code 128 / EAN 128 - Not Active (*)

Interleaved 2 of 5 - Not Active (*)

MS/2200/RM/00/E/970131

Code 128 / EAN 128 - Active

Interleaved 2 of 5 - Active

167

Page 178

Symbologies - Activation Matrix 2 of 5 - Not Active (*)

Matrix 2 of 5 - Active

The default format for Standard 2 of 5 is Identicon (6 Bars). Standard 2 of 5 - Not Active (*)

168

Standard 2 of 5 - Active

MS/2200/RM/00/E/970131

Page 179

Symbologies - Activation MSI Code - Not Active (*)

Plessey Code - Not Active (*)

MS/2200/RM/00/E/970131

MSI Code - Active

Plessey Code - Active

169

Page 180

Symbologies - Activation UPC/EAN - Not Active

UPC/EAN - Active (*)

Select the desired UPC/EAN format configuration and scan UPC/EAN - Active to enable.

UPC-A Transmitted as EAN-13 (*)

170

UPC-A Transmitted as UPC-A

MS/2200/RM/00/E/970131