The text of a manual · part 18 of 25
MaxiScan 2200 Reference Manual, pages 171 to 180
Pages 171 to 180 of 244
The original document is the PDF (753 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2200
Page 171
Standby mode Default standby settings Initial Standby After 15 Minutes (*)
Default values before standby: • initial standby: the laser beam is switched off after T = 15 minutes (900 seconds),
• full standby: the rotating mirror motor is switched off after an additional period of T x 2 = 30 minutes and a total period of inactivity of T x 3 = 45 minutes.
Composing a different time before standby Example
To change the time before initial standby to 10 minutes (600 seconds): 1. Scan Compose Time In Seconds Before Initial Standby. 2. Scan 6 0 0 and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual). The MaxiScan 2200 will go into initial standby after 10 minutes and full standby after a total of 30 minutes after the last read attempt.
Compose Time In Seconds Before Initial Standby
MS/2200/RM/00/E/970131
161
Page 172
Symbologies
Symbologies Available symbologies To optimize the performance of your MaxiScan 2200 and to ensure trouble-free scanning, do not select symbologies that you do not need. If possible, do not select more than 2 symbologies at the same time - deactivate the Code 39 and UPC/EAN default symbologies if you do not need to use them. Ð Symbologies - Codabar Ð Symbologies - Code 39 (*) Ð Symbologies - Code 128 / EAN 128 Ð Symbologies - Interleaved 2 of 5 Ð Symbologies - Matrix 2 of 5 Ð Symbologies - MSI Code Ð Symbologies - Plessey Code Ð Symbologies - Standard 2 of 5 Ð Symbologies - UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) (*)
Default symbologies Code 39 and the UPC/EAN code families are preselected by default. When you install and set up your MaxiScan 2200 for the first time, all the symbology parameters are set to their factory default settings - indicated by an asterisk (*) in this manual. The symbology default settings are global factory defaults - they are independent of the different symbology activation codes. If you want to reset all the default symbology settings, you can scan the Reset Factory Defaults bar code (Ð Reset all configuration parameters), but you will then have to completely reconfigure your MaxiScan 2200. It is often easier to scan Disable All Symbologies and reactivate individual symbologies ( Ð Symbologies - Activation ).
162
MS/2200/RM/00/E/970131
Page 173
Symbologies Character formats and MaxiScan 2200 transmission format symbology character format supported
MaxiScan 2200 transmission format
•
Code 39 alphanumeric - letter case not defined upper case
•
Code 128 alphanumeric full ASCII - letter case defined full ASCII - lower case/upper case as defined
• • • • •
Codabar Interleaved 2 of 5 Matrix 2 of 5, Standard 2 of 5 UPC/EAN code set numerical numerical
MS/2200/RM/00/E/970131
163
Page 174
Symbologies Barcode length and data security As well as barcode length parameters, other configuration parameters help to increase the security of the data transmitted ( Ð Data decoding security parameters ).
The reliability of the barcode data transmitted can depend on the symbologies used - some symbologies are more "fragile" than others and errors may occur due to incorrect interpretation of code lengths. Depending on the symbology used, the following barcode length parameters allow you to configure the MaxiScan 2200 to only accept codes which meet certain length requirements: •
Compose 1 Or 2 Or 3 Fixed Lengths - the safest option if you know that all the codes in your application have fixed lengths,
•
Compose Minimum Length - if there are variable code lengths but you know that there is a minimum length.
All symbologies except UPC/EAN are set to a minimum code length of 6 characters by default. You can use the special number codes (Ð Number codes or appendix at the end of this manual) or the ASCII character codes (Ð ASCII character codes) to enter the barcode lengths. If you use the Compose Minimum Length option, we recommend that you use a check digit (if available) and the Consecutive same read data validation feature (Ð Data decoding security parameters) to ensure that the same read result is obtained on 2 or more successive reads before the read is validated.
M Each symbology has its own set of configuration codes for barcode length parameters - you must only use the codes for your symbology.
164
MS/2200/RM/00/E/970131
Page 175
Symbologies - Activation
Symbologies - Activation To optimize the performance of your MaxiScan 2200 and to ensure trouble-free scanning, do not select symbologies that you do not need. If possible, do not select more than 2 symbologies at the same time - deactivate the Code 39 and UPC/EAN default symbologies if you do not need to use them. The symbology activation codes are also provided with the parameters for each symbology (Ð appropriate Symbologies section for your symbology).
Disable All Symbologies Disable All Symbologies deactivates all the symbologies activated. If you want to deactivate individual symbologies, use the Not Active codes for each symbology. Disable All Symbologies does not reset the individual parameter settings for each symbology. When you reactivate a symbology, you recover the parameter settings stored in memory for that symbology when it was disabled. If you want to reset all the symbology parameters to their factory default values, you must scan the Reset Factory Defaults bar code ( Ð Reset all configuration parameters ). Disable All Symbologies
MS/2200/RM/00/E/970131
165
Page 176
Symbologies - Activation Symbology activation codes Codabar - Not Active (*)
Codabar - Active
The default format for Code 39 is Standard 43 Characters. Code 39 - Not Active
166
Code 39 - Active (*)
MS/2200/RM/00/E/970131
Page 177
Symbologies - Activation Code 128 / EAN 128 - Not Active (*)
Interleaved 2 of 5 - Not Active (*)
MS/2200/RM/00/E/970131
Code 128 / EAN 128 - Active
Interleaved 2 of 5 - Active
167
Page 178
Symbologies - Activation Matrix 2 of 5 - Not Active (*)
Matrix 2 of 5 - Active
The default format for Standard 2 of 5 is Identicon (6 Bars). Standard 2 of 5 - Not Active (*)
168
Standard 2 of 5 - Active
MS/2200/RM/00/E/970131
Page 179
Symbologies - Activation MSI Code - Not Active (*)
Plessey Code - Not Active (*)
MS/2200/RM/00/E/970131
MSI Code - Active
Plessey Code - Active
169
Page 180
Symbologies - Activation UPC/EAN - Not Active
UPC/EAN - Active (*)
Select the desired UPC/EAN format configuration and scan UPC/EAN - Active to enable.
UPC-A Transmitted as EAN-13 (*)
170
UPC-A Transmitted as UPC-A
MS/2200/RM/00/E/970131