Page 161

RS-232 NAK negative acknowledge character Not Used (*)

NAK (HEX 15)

Scanning ACK or NAK activates the ACK/NAK protocol. If the MaxiScan 2200 receives a negative acknowledge (NAK) after sending a message, it will send the message again. If it receives a negative acknowledge (NAK) after the third transmission, the message is aborted (this behavior can be modified for special configurations). To use a different character for NAK: 1. Scan Compose Other NAK Character. 2. Scan the desired character code and scan End Selection to finish (Ð ASCII character codes).

Compose Other NAK Character

MS/2200/RM/00/E/970131

151

Page 162

RS-232 XON/XOFF software protocol Not Active (*)

Active

This protocol allows the host to control the flow of data from the MaxiScan 2200. To interrupt reception of data, the host transmits the XOFF character (ASCII DC3) after the specified time-out (ÐRS-232 - Hardware/software protocols time-out). To restart the flow, it sends the XON character (ASCII DC1).

CTS/RTS hardware protocol The MaxiScan 2200 acts as a standard terminal and manages the RTS/CTS lines when configured. RTS is activated (high) before data is transmitted and deactivated (low) when message transmission is completed after the specified time-out (ÐRS-232 - Hardware/software protocols time-out ). CTS is tested before transmission of each character. Data is only transmitted when CTS is activated (high). If CTS is not used by the host system, the MaxiScan 2200 maintains the level high.

Not Active (*)

152

Active

MS/2200/RM/00/E/970131

Page 163

RS-232 Preamble / postamble The MaxiScan 2200 can send preambles and postambles - control codes before and after each message - to emulate command keys on the keyboard and allow automatic data entry:

<preamble>

<barcode data>

<postamble>

Customizable barcode type code marks can be inserted after the preamble and before the barcode data (Ð Code mark).

No preamble / no postamble No Preamble (*)

No Postamble

MS/2200/RM/00/E/970131

153

Page 164

RS-232 Compose preamble / postamble Compose Preamble

Compose Postamble

Each preamble and postamble can contain a maximum of 10 characters

Example

To enter the STX character (ASCII character 02) as a preamble: 1. Scan Compose Preamble. 2. Scan one or more character codes you want to include in the preamble - in our example we would scan the ASCII STX character code - and scan End Selection to finish ( Ð ASCII character codes ).

Predefined preamble/postamble code Preamble = STX And Postamble = ETX

154

MS/2200/RM/00/E/970131

Page 165

RS-232 Predefined postamble codes Carriage Return + Line Feed (*)

Carriage Return

MS/2200/RM/00/E/970131

Line Feed

155

Page 166

RS-232 Transmission delay Ð Inter-character delay Ð Inter-message delay

156

MS/2200/RM/00/E/970131

Page 167

RS-232 - Monitor mode

RS-232 - Monitor mode Monitor mode allows the MaxiScan 2200 to be configured or controlled directly by the terminal host via the RS-232 port.

1. Scan RS-232 Monitor Mode to activate monitor mode. 2. Look for the desired command strings in the parameter list (Ð Parameter list / data strings) or put the MaxiScan 2200 into Display Data String Mode (Ð Configuration modes - Display data string mode) and read the codes you want the host to transmit - the data string of each code you read will be displayed on the terminal screen. 3. Transmit the commands from the host terminal to the MaxiScan 2200. You can send monitor mode commands individually or make a list in a command file. Monitor mode uses hexadecimal values. Make sure that the values you send from the host system correspond to these values. For the value "\41" for example, the MaxiScan 2200 must receive the hexadecimal value 41 or its equivalent (ASCII character "A", for example), not the decimal value 41. To quit monitor mode, switch off the MaxiScan 2200 or scan Reset Factory Defaults (Ð Reset all configuration parameters ).

RS-232 Monitor Mode

MS/2200/RM/00/E/970131

157

Page 168

Scan rate

Scan rate 1400 Scans Per Second (*)

The default scan rate of 1400 scans per second is suitable for normal-quality mediumresolution bar codes such as standard EAN (100%). For other reading situations, you will optimize reading performance by finding the best scan rate for the bar codes you want to read.

reading situation normal-quality medium-resolution bar codes such as standard EAN (100% magnitude)

1400 Scans Per Second (*)

increased reading range for high-density bar codes (narrow bar width between 0.125 mm and 0.2 mm)

1200 Scans Per Second fast reading of normal-quality UPC/EAN bar codes

1600 Scans Per Second

1200 Scans Per Second

158 scan rate

1600 Scans Per Second

MS/2200/RM/00/E/970131

Page 169

Software version identification

Software version identification Software Version Software Version displays on the host terminal screen (if applicable) the version of the software installed in the MaxiScan 2200. Software version information is useful if you have a problem and need to contact your UBI representative (Ð Troubleshooting ).

Software Version

MS/2200/RM/00/E/970131

159

Page 170

Standby mode

Standby mode Standby Mode Enable (*)

Standby mode increases the lifetime of the laser diode (initial standby) and rotating mirror motor (full standby): • after an initial period of inactivity (T), the laser beam is switched off automatically,

• after an additional period of inactivity (T x 2) - and a total period of inactivity T x 3 - the rotating mirror motor is switched off.

The MaxiScan 2200 is reactivated when you try to read a new bar code. Wake-up is quicker after initial standby than after full standby.

last read attempt

Tx3 T MaxiScan 2200 active: • laser beam on • rotating mirror motor on

Tx2 initial standby: • laser beam off • rotating mirror motor on full standby: • laser beam off • rotating mirror motor off

Standby Mode Disable

160

MS/2200/RM/00/E/970131