The text of a manual · part 16 of 25
MaxiScan 2200 Reference Manual, pages 151 to 160
Pages 151 to 160 of 244
The original document is the PDF (753 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2200
Page 151
RS-232 Predefined data transmission settings Predefined settings for RS-232 C - Interface N° 100 baud rate
-
9600 data bits
-
7 parity
- even stop bits
-
2
ENQ (Hex 05)
- not used
ACK (Hex 06)
- not used
NAK (Hex 15)
- not used
XON/XOFF (software)
- inactive
CTS/RTS (hardware)
- inactive
LRC (longitudinal redundancy check)
- inactive time-out (hardware and software)
-
1000 ms preamble none postamble
-
Carriage Return + Line Feed inter-character delay
- none inter-message delay
- none
In this section, the predefined parameter settings for interface N° 100 (Standard RS-232) are indicated by an asterisk (*).
MS/2200/RM/00/E/970131
141
Page 152
RS-232 Baud Rate 9600 (*)
75
150
300
142
MS/2200/RM/00/E/970131
Page 153
RS-232 Baud Rate 600
1200
2400
4800
MS/2200/RM/00/E/970131
143
Page 154
RS-232 Baud Rate 19200
38400
Data bits Seven (*)
144
Eight
MS/2200/RM/00/E/970131
Page 155
RS-232 Parity Even (*)
Odd
None
MS/2200/RM/00/E/970131
145
Page 156
RS-232 Stop bits Two (*)
One
146
MS/2200/RM/00/E/970131
Page 157
RS-232 Hardware/software protocols time-out 1000 ms (*)
Unlimited Time-Out (value = 0)
The same time-out value applies to all the RS-232 protocols supported by the MaxiScan 2200: •
ENQ / ACK / NAK software protocol,
•
XON / XOFF software protocol,
•
CTS / RTS hardware protocol.
Compose hardware/software protocols time-out Example
To set a hardware and software timeout of 2 seconds (= 2000 ms): 1. Scan Compose Time-Out. 2. Scan the desired value in milliseconds - in our example we would scan 2 0 0 0 - and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).
Compose Time-Out (minimum = 1 ms, maximum = 2500 ms)
MS/2200/RM/00/E/970131
147
Page 158
RS-232 ENQ / ACK / NAK software protocol Typical ENQ / ACK / NAK scenarios host terminal
MaxiScan 2200
ENQ message (OK)
ACK (clears message)
host terminal
MaxiScan 2200
ENQ message (not OK)
NAK repeats message (OK)
ACK (clears message)
148
MS/2200/RM/00/E/970131
Page 159
RS-232 ENQ enquiry character Not Used (*)
ENQ (HEX 05)
If ENQ is not used, the MaxiScan 2200 transmits barcode data without waiting for a request from the host system. If an ENQ character is activated, the MaxiScan 2200 waits to receive the ENQ character from the host system before transmitting data after a good read. If no character is received before the end of the specified time-out (ÐRS-232 - Hardware/software protocols time-out), the data is not transmitted (except for special configurations). To use a different character for ENQ: 1. Scan Compose Other ENQ Character. 2. Scan the desired character code and scan End Selection to finish (Ð ASCII character codes).
Compose Other ENQ Character
MS/2200/RM/00/E/970131
149
Page 160
RS-232 ACK positive acknowledge character Not Used (*)
ACK (HEX 06)
Scanning ACK or NAK activates the ACK/NAK protocol. After a successful message transmission, the MaxiScan 2200 waits until the end of the protocol time-out before reading a new bar code. If there is no positive acknowledge (ACK) before the end of the specified time-out (ÐRS-232 - Hardware/software protocols time-out), the MaxiScan 2200 processes as if there was a positive acknowledge (this behavior can be modified for special configurations). To use a different character for ACK: 1. Scan Compose Other ACK Character. 2. Scan the desired character code and scan End Selection to finish (Ð ASCII character codes).
Compose Other ACK Character
150
MS/2200/RM/00/E/970131