Page 151

RS-232 Predefined data transmission settings Predefined settings for RS-232 C - Interface N° 100 baud rate

-

9600 data bits

-

7 parity

- even stop bits

-

2

ENQ (Hex 05)

- not used

ACK (Hex 06)

- not used

NAK (Hex 15)

- not used

XON/XOFF (software)

- inactive

CTS/RTS (hardware)

- inactive

LRC (longitudinal redundancy check)

- inactive time-out (hardware and software)

-

1000 ms preamble none postamble

-

Carriage Return + Line Feed inter-character delay

- none inter-message delay

- none

In this section, the predefined parameter settings for interface N° 100 (Standard RS-232) are indicated by an asterisk (*).

MS/2200/RM/00/E/970131

141

Page 152

RS-232 Baud Rate 9600 (*)

75

150

300

142

MS/2200/RM/00/E/970131

Page 153

RS-232 Baud Rate 600

1200

2400

4800

MS/2200/RM/00/E/970131

143

Page 154

RS-232 Baud Rate 19200

38400

Data bits Seven (*)

144

Eight

MS/2200/RM/00/E/970131

Page 155

RS-232 Parity Even (*)

Odd

None

MS/2200/RM/00/E/970131

145

Page 156

RS-232 Stop bits Two (*)

One

146

MS/2200/RM/00/E/970131

Page 157

RS-232 Hardware/software protocols time-out 1000 ms (*)

Unlimited Time-Out (value = 0)

The same time-out value applies to all the RS-232 protocols supported by the MaxiScan 2200: •

ENQ / ACK / NAK software protocol,

•

XON / XOFF software protocol,

•

CTS / RTS hardware protocol.

Compose hardware/software protocols time-out Example

To set a hardware and software timeout of 2 seconds (= 2000 ms): 1. Scan Compose Time-Out. 2. Scan the desired value in milliseconds - in our example we would scan 2 0 0 0 - and scan End Selection to finish ( Ð Number codes or appendix at the end of this manual).

Compose Time-Out (minimum = 1 ms, maximum = 2500 ms)

MS/2200/RM/00/E/970131

147

Page 158

RS-232 ENQ / ACK / NAK software protocol Typical ENQ / ACK / NAK scenarios host terminal

MaxiScan 2200

ENQ message (OK)

ACK (clears message)

host terminal

MaxiScan 2200

ENQ message (not OK)

NAK repeats message (OK)

ACK (clears message)

148

MS/2200/RM/00/E/970131

Page 159

RS-232 ENQ enquiry character Not Used (*)

ENQ (HEX 05)

If ENQ is not used, the MaxiScan 2200 transmits barcode data without waiting for a request from the host system. If an ENQ character is activated, the MaxiScan 2200 waits to receive the ENQ character from the host system before transmitting data after a good read. If no character is received before the end of the specified time-out (ÐRS-232 - Hardware/software protocols time-out), the data is not transmitted (except for special configurations). To use a different character for ENQ: 1. Scan Compose Other ENQ Character. 2. Scan the desired character code and scan End Selection to finish (Ð ASCII character codes).

Compose Other ENQ Character

MS/2200/RM/00/E/970131

149

Page 160

RS-232 ACK positive acknowledge character Not Used (*)

ACK (HEX 06)

Scanning ACK or NAK activates the ACK/NAK protocol. After a successful message transmission, the MaxiScan 2200 waits until the end of the protocol time-out before reading a new bar code. If there is no positive acknowledge (ACK) before the end of the specified time-out (ÐRS-232 - Hardware/software protocols time-out), the MaxiScan 2200 processes as if there was a positive acknowledge (this behavior can be modified for special configurations). To use a different character for ACK: 1. Scan Compose Other ACK Character. 2. Scan the desired character code and scan End Selection to finish (Ð ASCII character codes).

Compose Other ACK Character

150

MS/2200/RM/00/E/970131