Page 191

Symbologies - Code 39 (*) Check digit Deactivation Not Used (*)

Modulo 43 check digit The modulo 43 check digit is a character added to the end of the Code 39 barcode label for extra validation of the data.

Checked And Transmitted

Checked But Not Transmitted

MS/2200/RM/00/E/970131

181

Page 192

Symbologies - Code 39 (*) Check digit French CIP check digit French CIP Check Digit Checked And Transmitted

French CIP Check Digit Checked But Not Transmitted

The French CIP check digit is used in the French pharmaceutical industry. It is only used for codes with seven characters. If the French CIP check digit is used, the MaxiScan 2200 automatically performs code reconstruction to optimize reading.

Italian CPI check digit The Italian CPI check digit is used in the Italian pharmaceutical industry. If the Code 39 read does not match an Italian checksum, it is transmitted as a standard Code 39. If the Italian CPI check digit is used, the MaxiScan 2200 automatically performs code reconstruction to optimize reading. Italian CPI Check Digit Checked And Transmitted

182

Italian CPI Check Digit Checked But Not Transmitted

MS/2200/RM/00/E/970131

Page 193

Symbologies - Code 39 (*) Barcode length Minimum Length = 6 (*)

Return To Current Minimum Length

Barcode length (number of characters) for Code 39 = [start + barcode data + check digit if applicable + stop]. The minimum length possible is 3 characters. If you scan Compose 1 Or 2 Or 3 Fixed Lengths or Compose Minimum Length, use the special number codes (Ð Number codes or appendix at the end of this manual) or the ASCII character codes (Ð ASCII character codes ) to enter the barcode lengths. Compose 1 Or 2 Or 3 Fixed Lengths provides the most security if the codes in your application have fixed lengths: • if you use the number codes, scan End Selection after each length and scan End Selection a second time when you have finished (after 1, 2 or 3 fixed lengths),

• if you use the ASCII codes, do not scan End Selection until you have finished entering all the lengths (after 1, 2 or 3 fixed lengths).

If only 1 fixed length is entered, the MaxiScan 2200 automatically performs code reconstruction to optimize reading. Compose Minimum Length provides a certain degree of security if you know the minimum length of the codes in your application - enter the minimum length (number codes or ASCII code) and scan End Selection to finish. Return To Current Minimum Length cancels any fixed length settings.

Compose Minimum Length

Compose 1 Or 2 Or 3 Fixed Lengths

MS/2200/RM/00/E/970131

183

Page 194

Symbologies - Code 128 / EAN 128

Symbologies - Code 128 / EAN 128 Activation Not Active (*)

Active

New normalization allows decoding of the UCC/EAN standard extension. EAN 128 is autodiscriminating with Code 128 (recognition of the FNC1 start character used).

Default values CIP 128 French pharmaceutical codes

-

Not Active

FNC1 separator character for EAN-128 norms

-

GS function character (ASCII 29)

Number of characters

-

Minimum Length = 6

CIP 128 French pharmaceutical codes CIP 128 French pharmaceutical bar codes have the following characteristics: • embedded CIP 39 data,

• fixed length 14 characters,

•

Code 128 character set C.

CIP 128 - Not Active (*)

184

CIP 128 - Active

MS/2200/RM/00/E/970131

Page 195

Symbologies - Code 128 / EAN 128 Code EAN-128 norms (auto-discriminating) Compose FNC1 separator character Inside the code, the FNC1 character can be used as a separator when multiple identifiers and their fields are concatenated. It is transmitted as the GS function character (ASCII 29) by default and can be substituted by your own ASCII character (used for example for keyboard wedge interfaces where the GS character can not be transmitted).

Example

If you want to use SP (ASCII character 32) as FNC1 separator character: 1. Use your MaxiScan 2200 to read the Compose Other Character bar code. 2. Scan the desired ASCII character and scan End Selection ( Ð ASCII character codes ).

Compose Other Character (default = GS, ASCII character 29)

MS/2200/RM/00/E/970131

185

Page 196

Symbologies - Code 128 / EAN 128 Barcode length Minimum Length = 6 (*)

Return To Current Minimum Length

Barcode length (number of characters) for Code 128 / EAN 128 = [barcode data]. The minimum length possible is 1 character.

M Code 128 / EAN 128 does not use the same number of characters to code alphanumerical data and numerical data. If the MaxiScan 2200 does not read bar codes in your application, this may be due to unsuitable minimum or fixed lengths - try entering shorter lengths to get round this problem. If you scan Compose 1 Or 2 Or 3 Fixed Lengths or Compose Minimum Length, use the special number codes (Ð Number codes or appendix at the end of this manual) or the ASCII character codes (Ð ASCII character codes ) to enter the barcode lengths. Compose 1 Or 2 Or 3 Fixed Lengths provides the most security if the codes in your application have fixed lengths: • if you use the number codes, scan End Selection after each length and scan End Selection a second time when you have finished (after 1, 2 or 3 fixed lengths),

• if you use the ASCII codes, do not scan End Selection until you have finished entering all the lengths (after 1, 2 or 3 fixed lengths).

Compose Minimum Length provides a certain degree of security if you know the minimum length of the codes in your application - enter the minimum length (number codes or ASCII code) and scan End Selection to finish. Return To Current Minimum Length cancels any fixed length settings.

Compose Minimum Length

186

Compose 1 Or 2 Or 3 Fixed Lengths

MS/2200/RM/00/E/970131

Page 197

Symbologies - EAN-8, EAN-13

Symbologies - EAN-8, EAN-13 Ð Symbologies - UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13)

MS/2200/RM/00/E/970131

187

Page 198

Symbologies - EAN 128

Symbologies - EAN 128 Ð Symbologies - Code 128 / EAN 128

188

MS/2200/RM/00/E/970131

Page 199

Symbologies - Interleaved 2 of 5

Symbologies - Interleaved 2 of 5 Activation Not Active (*)

Active

Default values Check digit

-

Not used

Number of characters

-

Minimum Length = 6

MS/2200/RM/00/E/970131

189

Page 200

Symbologies - Interleaved 2 of 5 Check digit Not Used (*)

An Interleaved 2 of 5 check digit can be used as the last encoded character of a label. This is especially recommended when using variable length Interleaved 2 of 5 and if the Consecutive same read data validation feature is not activated (Ð Data decoding security parameters).

Check digit mod 10 Checked And Transmitted

190

Checked But Not Transmitted