The text of a manual · part 6 of 11
Decoding Laser Scanner User's Manual, pages 51 to 60
Pages 51 to 60 of 110
The original document is the PDF (318 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1551
Page 51
Configuring the Scanner
3
Configuring Bar Code Parameters You can configure these bar code parameters (not available for 15XXX03): •
Prefix
•
Suffix
•
Terminal ID
•
Bar code ID
•
Preamble
•
Postamble
Prefix The prefix identifies the start of a data string and is represented by a code that is determined by an industry standard. The prefixes available are STX (start of transmission code) and SOH (start of header code). Scan a bar code to enable the prefix used by your system (not available for 15XXX03). No Prefix*
IA
STX
IB
SOH
IC
* Default
3-17
Page 52
Decoding Laser Scanner User’s Manual
Suffix The suffix marks the end of a data string and, like the prefix, it is assigned a specific ASCII code that conforms to a standard. The available suffixes are CR (carriage return), LF (line feed), CR and LF, ETX (end of transmission), and HT (horizontal tab). Scan a bar code to enable the suffix used with your system (not available for 15XXX03). No suffix*
MA
ETX
MB
CR
MC
LF
MD
HT
ME
CR and LF**
MF
* Default for Keyboard Wedge mode. ** Default for Serial mode.
3-18
Page 53
Configuring the Scanner
3
Terminal ID Terminal IDs are used to identify individual scanners for host systems that interface with many scanners. Two digits (01 to 99) are used for terminal IDs. To configure terminal ID 1. Scan a bar code (not available for 15XXX03): Terminal ID Disabled*
JA
Terminal ID
JB
* Default. 2. If you scan “Terminal ID,” enter two digits between 01 and 99 using the conversion chart in Appendix A.
Bar Code ID If your system uses different types of bar code symbologies, it may require a bar code ID. The ID is a single character that is transmitted with each message identifying the bar code scanned. ID characters are: Code 39 a
Interleaved 2 of 5 Standard 2 of 5 b c
UPC/EAN/JA N Code 128 Codabar d f h
To configure a bar code ID Scan one of these bar codes to enable or disable the bar code ID (not available for 15XXX03): Disable Bar Code ID*
FA
Enable Bar Code ID
FB
* Default.
3-19
Page 54
Decoding Laser Scanner User’s Manual
Preamble and Postamble Preambles and postambles are character strings that precede and follow the actual message. Each preamble and postamble consists of four ASCII characters, each is represented by two hexadecimal numbers. If they are used in your system, only those codes with the correct preamble and postamble are accepted. To configure a preamble or a postamble 1. Scan one of these bar codes (not available for 15XXX03): No Preamble*
KA
No Postamble*
LA
Enter Preamble
KB
Enter Postamble
LB
* Default. 2. If you scanned “Enter Preamble” or “Enter Postamble,” enter four characters using the conversion chart in Appendix A.
3-20
Page 55
Configuring the Scanner
3
Configuring Operating Parameters You can configure these scanner operating parameters: •
Power consumption
•
Beeper volume
•
Laser redundancy
•
Spotter beam
•
External trigger
•
Reading Uppercase Letters
•
Reading Special Characters
•
International Keyboards
Power Consumption Power consumption parameters determine if the scanner reverts to standby when not scanning. With standby enabled, the scanner draws very little power between scans and conserves power. Scan a bar code to select the type of power consumption for your scanner (not available for 15XXX03): Continuous Full Power*
@A
Standby Enabled**
@B
* Default for 1551X03 and 15XXX07 scanners. ** Default for 15XXX02 scanners.
3-21
Page 56
Decoding Laser Scanner User’s Manual
Beep Volume Scan one of these bar codes to set the scanner beep volume (not available for 15XXX03): Off (no beeper)
AA
Softest
AB
Medium
AC
Loudest*
AD
* Default.
Laser Redundancy Laser redundancy checks each scan by creating a duplicate scan and comparing the information, which must match for a successful read. This feature increases the integrity of the scanners since it creates an automatic error check. Scan a bar code to enable or disable laser redundancy (not available for 15XXX03): Disabled*
BC
Enable (2X)
BD
Enable (4X)
BE
* Default.
3-22
Page 57
Configuring the Scanner
3
Spotter Beam The spotter beam lets you see where the laser beam will scan before a bar code is actually read. With the spotter beam enabled, you can press the scanner trigger and have a small laser dot appear (for a preset time) where the full laser beam will scan, and then the scanner will read that bar code. Use the spotter beam if you have trouble scanning bar codes that are far away, in a group of closely printed bar codes (for example, Appendix B), in a bright environment, or in a glass showcase. To configure spotter beam 1. Scan a bar code to enable or disable the spotter beam: Disable Spotter Beam
NP
Enable Spotter Beam
NQ
2. If you scan “Enable Spotter Beam,” enter a spotter beam duration between 0 and 9 using the conversion chart in Appendix A.
External Trigger The external trigger lets you program your scanner to be enabled from a computer or other external device. Unlike the scanner stand, which activates the scanner when the beam path is interrupted, the external trigger responds to a signal at the CTS input. This signal starts the scan and continues until the label is decoded, or the signal times out (approximately 6 seconds). The external trigger can be activated as External Trigger (+), which activates scanning when the CTS input is high, or External Trigger (-), which activates scanning when the CTS input is low. When CTS is not connected, it is treated as if it
3-23
Page 58
Decoding Laser Scanner User’s Manual were a high input (for both settings). See the modular connector for the voltage levels. Note: The trigger must be deactivated for a minimum of 50 ms between scans to verify trigger cycling. Forcing the signal to active at all times does not create continuous scanning and decoding. Scan a bar code below to set the external trigger (not available if using 15XXX03 or 1551X07): Disabled*
HA
External Trigger (+)
HE
External Trigger (-)
HF
* Default.
Reading Uppercase Letters When the Caps Lock key is used on the reader/terminal, you must also configure the scanner to read and decode the uppercase letters in a bar code. Scan the Shift Alphabetic Characters bar code (EO) to configure the scanner to read all uppercase letters. Scan the Normal Alphabetic Character (EP) to return to reading lowercase letters. (Not available for 15XXX02 and 15XXX03.) Note: To use the symbols above the number keys (for example: !@#$%^&*), see the next section “Reading Symbols.” Shift Alphabetic Characters
EO
Normal Alphabetic Characters
EP
3-24
Page 59
Configuring the Scanner
3
Reading Symbols When the Shift key is used on the reader/terminal, you must also configure the scanner to read and decode the symbols (for example: !@#$%^&*) in a bar code. Scan a bar code to enable or disable shift lock (not available for 15XXX02 and 15XXX03): Enable Shift Lock
ES
Disable Shift Lock
ET
Note: To read uppercase letters, see the previous section “Reading Uppercase Letters.”
International Keyboards Scan a bar code to configure a 15XXX07 for one of these keyboards (not available on 15XXX02 and 15XXX03): PC/AT German
CV
PC/AT French
CW
PC/AT United Kingdom
CX
PC/AT Belgian
\B
PC/AT Swiss
\C
PC/AT Danish
\D
3-25
Page 60
Decoding Laser Scanner User’s Manual International Keyboards (continued) PC/AT Spanish
\F
PC/AT Swedish
\G
PC/AT Portuguese
\H
DEC VT 220/320/420 German Keyboard Wedge
\L
DEC VT 220/320/420 French Keyboard Wedge
\M
Using an International Keyboard With a Laptop If you use a laptop with an international keyboard you need to enable the keyboard. Scan a bar code to enable or disable the keyboard: Enable Execution of Keyboard POR (Power on Reset)
\J
Disable Execution of Keyboard POR (Power on Reset)
\M
3-26