The text of a manual · part 5 of 11
Decoding Laser Scanner User's Manual, pages 41 to 50
Pages 41 to 50 of 110
The original document is the PDF (318 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1551
Page 41
Configuring the Scanner
3
The minimum label lengths are set to one character, except for I 2 of 5, which is set to 14 characters, and standard 2 of 5, which is set to 4 characters. If maximum length is not programmed, the scanner will limit the bar code length to 32 characters. To reset your scanner to default values, scan this bar code: Reset to Default Values
ZA
To set up Intermec default values, scan this bar code: Intermec Default Wand emulation: white high, 50 ips Communications: 9600, e, 7, 1
Z5
Configuring Bar Code Symbologies You can configure these symbologies on your scanner: • • • • •
UPC-A EAN/JAN Standard 2 of 5 Code 128 Code 93
• • • • •
UPC-E Code 39 Interleaved 2 of 5 Codabar Code 11
Configure only the symbologies you will use and disable any symbologies you will not use. This will help increase scanning speed. For example, if you are using a 15XXX02 scanner, four symbologies including Code 39 are automatically activated. If you will not scan Code 39 bar codes, disable the Code 39 symbology by scanning the Disable Code 39 (OA) bar code command found later in this section or in Appendix B.
3-7
Page 42
Decoding Laser Scanner User’s Manual
UPC-A and UPC-E Scan the appropriate bar code to enable or disable UPC symbology. When enabled, the UPC codes, with or without a supplement, can be scanned. Enabling the supplement (2 or 5 digits) lets the scanner read the supplement as well. Enable UPC-A and UPC-E Supplement allowed
QB
Enable UPC-A and UPC-E Supplement disabled*
QC
Enable Expanded UPC-E
QI
Disable Expanded UPC-E
QH
Enable Transmit UPC-A as EAN-13
QJ
Disable Transmit UPC-A as EAN-13**
QK
Disabled (A and E)
QA
* Default for all scanners. ** Default for all modes. Continue to the next section to configure a number system digit and a check digit.
3-8
Page 43
Configuring the Scanner
3
UPC Number System Digit Scan the appropriate bar code to enable or disable the number system digit (the first character in a UPC symbol). Enable UPC Transmit of Number System Digit
QE
Disable UPC Transmit of Number System Digit
QD
UPC Check Digit Scan a bar code to enable or disable the check digit (the last character in a UPC symbol). Enabled*
QG
Disabled
QF
* Default for all modes.
EAN/JAN Scan the appropriate code to enable or disable EAN 8 digit and 13 digit. When EAN/JAN is enabled, all EAN/JAN codes, with or without a supplement, can be scanned. Enabling the supplement (2 or 5 digits) lets the scanner read the supplement as well. Disabled - both 8 and 13 digit*
RA
Enabled - Supplement enabled (2 or 5 digit)
RB
Enabled - Supplement disabled (2 or 5 digit)
RC
Continue to the next section to configure a number system digit and a check digit. 3-9
Page 44
Decoding Laser Scanner User’s Manual
EAN/JAN Number System Digit Scan the appropriate bar code to enable or disable the number system digit (the first character in a UPC symbol). Disable Number System Digit
RD
Enable Number System Digit*
RE
EAN/JAN Check Digit Scan a bar code to enable or disable the check digit (the last character in a UPC symbol). Enable Check Digit*
RG
Disable Check Digit
RF
* Default for all modes.
3-10
Page 45
Configuring the Scanner
3
Code 39 These bar codes configure your scanner for Code 39 scanning capabilities. Disable
OA
Enable Standard Code 39*
OB
Full ASCII Code 39
OC
Disable Modulo 43 Check Character**
OD
Enable Modulo 43 Check Character
OE
Transmit START and STOP Characters
OG
Do not transmit START and STOP Characters**
OF
* Default for 15XXX02 and 15XXX07 scanners. ** Default for all modes. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
OH
Maximum Length
OI
2. Enter a length between 01 and 32 using the conversion chart in Appendix A.
3-11
Page 46
Decoding Laser Scanner User’s Manual
Standard 2 of 5 These bar codes configure your scanner for 2 of 5 scanning capabilities. Enable
PG
Disable*
PF
* Default for all modes. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
PH
Maximum Length
PI
2. Enter a length between 01 and 32 using the conversion chart in Appendix A.
Interleaved 2 of 5 These bar codes configure your scanner for I 2 of 5 scanning capabilities. Disable*
PA
Enable with Check Digit
PC
Enable without Check Digit
PB
* Default for all modes.
3-12
Page 47
Configuring the Scanner
3
To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
PD
Maximum Length
PE
2. Enter a length between 02 and 32 using the conversion chart in Appendix A.
Code 128 These bar codes configure your scanner for Code 128 scanning. Enable*
TB
Disable
TA
* Default for 15XXX02 and 15XXX07 scanners. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
TC
Maximum Length
TD
2. Enter a length between 01 and 32 using the conversion chart in Appendix A.
3-13
Page 48
Decoding Laser Scanner User’s Manual
Codabar These bar codes configure your scanner for Codabar scanning capabilities. Enable
VB
Disable*
VA
Transmit START and STOP characters
VD
Do not transmit START and STOP characters
VC
* Default for all scanners. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
VE
Maximum Length
VF
2. Enter a length between 01 and 32 using the conversion chart in Appendix A.
3-14
Page 49
Configuring the Scanner
3
Code 93 These bar codes configure your scanner for Code 93 scanning capabilities. Disable*
UA
Enable Code 93
UB
Standard Code 93
UC
Enable Full ASCII Code 93
UD
* Default for 15XXX02 and 15XXX07 scanners. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
UE
Maximum Length
UF
2. Enter a length between 01 and 32 using the conversion chart in Appendix A.
3-15
Page 50
Decoding Laser Scanner User’s Manual
Code 11 These bar codes configure your scanner for Code 11 scanning capabilities. Disable Code 11
SA
Enable Code 11 With One Check Digit
SB
Enable Code 11 With Two Check Digits
SC
Disable Transmit of Code 11 Check Digits
SD
Enable Transmit of Code 11 Check Digits
SE
To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length
SF
Maximum Length
SG
2. Enter a length between 01 and 32 using the conversion chart in Appendix A.
3-16