Page 41

Configuring the Scanner

3

The minimum label lengths are set to one character, except for I 2 of 5, which is set to 14 characters, and standard 2 of 5, which is set to 4 characters. If maximum length is not programmed, the scanner will limit the bar code length to 32 characters. To reset your scanner to default values, scan this bar code: Reset to Default Values

ZA

To set up Intermec default values, scan this bar code: Intermec Default Wand emulation: white high, 50 ips Communications: 9600, e, 7, 1

Z5

Configuring Bar Code Symbologies You can configure these symbologies on your scanner: • • • • •

UPC-A EAN/JAN Standard 2 of 5 Code 128 Code 93

• • • • •

UPC-E Code 39 Interleaved 2 of 5 Codabar Code 11

Configure only the symbologies you will use and disable any symbologies you will not use. This will help increase scanning speed. For example, if you are using a 15XXX02 scanner, four symbologies including Code 39 are automatically activated. If you will not scan Code 39 bar codes, disable the Code 39 symbology by scanning the Disable Code 39 (OA) bar code command found later in this section or in Appendix B.

3-7

Page 42

Decoding Laser Scanner User’s Manual

UPC-A and UPC-E Scan the appropriate bar code to enable or disable UPC symbology. When enabled, the UPC codes, with or without a supplement, can be scanned. Enabling the supplement (2 or 5 digits) lets the scanner read the supplement as well. Enable UPC-A and UPC-E Supplement allowed

QB

Enable UPC-A and UPC-E Supplement disabled*

QC

Enable Expanded UPC-E

QI

Disable Expanded UPC-E

QH

Enable Transmit UPC-A as EAN-13

QJ

Disable Transmit UPC-A as EAN-13**

QK

Disabled (A and E)

QA

* Default for all scanners. ** Default for all modes. Continue to the next section to configure a number system digit and a check digit.

3-8

Page 43

Configuring the Scanner

3

UPC Number System Digit Scan the appropriate bar code to enable or disable the number system digit (the first character in a UPC symbol). Enable UPC Transmit of Number System Digit

QE

Disable UPC Transmit of Number System Digit

QD

UPC Check Digit Scan a bar code to enable or disable the check digit (the last character in a UPC symbol). Enabled*

QG

Disabled

QF

* Default for all modes.

EAN/JAN Scan the appropriate code to enable or disable EAN 8 digit and 13 digit. When EAN/JAN is enabled, all EAN/JAN codes, with or without a supplement, can be scanned. Enabling the supplement (2 or 5 digits) lets the scanner read the supplement as well. Disabled - both 8 and 13 digit*

RA

Enabled - Supplement enabled (2 or 5 digit)

RB

Enabled - Supplement disabled (2 or 5 digit)

RC

Continue to the next section to configure a number system digit and a check digit. 3-9

Page 44

Decoding Laser Scanner User’s Manual

EAN/JAN Number System Digit Scan the appropriate bar code to enable or disable the number system digit (the first character in a UPC symbol). Disable Number System Digit

RD

Enable Number System Digit*

RE

EAN/JAN Check Digit Scan a bar code to enable or disable the check digit (the last character in a UPC symbol). Enable Check Digit*

RG

Disable Check Digit

RF

* Default for all modes.

3-10

Page 45

Configuring the Scanner

3

Code 39 These bar codes configure your scanner for Code 39 scanning capabilities. Disable

OA

Enable Standard Code 39*

OB

Full ASCII Code 39

OC

Disable Modulo 43 Check Character**

OD

Enable Modulo 43 Check Character

OE

Transmit START and STOP Characters

OG

Do not transmit START and STOP Characters**

OF

* Default for 15XXX02 and 15XXX07 scanners. ** Default for all modes. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

OH

Maximum Length

OI

2. Enter a length between 01 and 32 using the conversion chart in Appendix A.

3-11

Page 46

Decoding Laser Scanner User’s Manual

Standard 2 of 5 These bar codes configure your scanner for 2 of 5 scanning capabilities. Enable

PG

Disable*

PF

* Default for all modes. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

PH

Maximum Length

PI

2. Enter a length between 01 and 32 using the conversion chart in Appendix A.

Interleaved 2 of 5 These bar codes configure your scanner for I 2 of 5 scanning capabilities. Disable*

PA

Enable with Check Digit

PC

Enable without Check Digit

PB

* Default for all modes.

3-12

Page 47

Configuring the Scanner

3

To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

PD

Maximum Length

PE

2. Enter a length between 02 and 32 using the conversion chart in Appendix A.

Code 128 These bar codes configure your scanner for Code 128 scanning. Enable*

TB

Disable

TA

* Default for 15XXX02 and 15XXX07 scanners. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

TC

Maximum Length

TD

2. Enter a length between 01 and 32 using the conversion chart in Appendix A.

3-13

Page 48

Decoding Laser Scanner User’s Manual

Codabar These bar codes configure your scanner for Codabar scanning capabilities. Enable

VB

Disable*

VA

Transmit START and STOP characters

VD

Do not transmit START and STOP characters

VC

* Default for all scanners. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

VE

Maximum Length

VF

2. Enter a length between 01 and 32 using the conversion chart in Appendix A.

3-14

Page 49

Configuring the Scanner

3

Code 93 These bar codes configure your scanner for Code 93 scanning capabilities. Disable*

UA

Enable Code 93

UB

Standard Code 93

UC

Enable Full ASCII Code 93

UD

* Default for 15XXX02 and 15XXX07 scanners. To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

UE

Maximum Length

UF

2. Enter a length between 01 and 32 using the conversion chart in Appendix A.

3-15

Page 50

Decoding Laser Scanner User’s Manual

Code 11 These bar codes configure your scanner for Code 11 scanning capabilities. Disable Code 11

SA

Enable Code 11 With One Check Digit

SB

Enable Code 11 With Two Check Digits

SC

Disable Transmit of Code 11 Check Digits

SD

Enable Transmit of Code 11 Check Digits

SE

To set the bar code length (optional) 1. Scan the appropriate bar code below. Minimum Length

SF

Maximum Length

SG

2. Enter a length between 01 and 32 using the conversion chart in Appendix A.

3-16