Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 11

Decoding Laser Scanner User's Manual, pages 61 to 70

Pages 61 to 70 of 110

The original document is the PDF (318 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 1551

Page 61

Configuring the Scanner

3

Configuring the 15XXX02 Serial Parameters You can configure these serial communications parameters for a 15XXX02 scanner: •

Baud rate

•

Intercharacter delay

•

Data bits

•

Protocol

•

Label buffer

Note: If you are using your 15XXX02 scanner with a portable reader, you must configure the scanner by scanning the bar codes in this manual. If you are configuring the scanner from a host terminal see “Configuring the Scanner From a Host Terminal” earlier in this chapter.

Baud Rate The baud rate is the rate at which information reaches the terminal in data bits per second. Scan one of these bar codes to set the baud rate: 300

DA

600

DB

1200

DC

2400

DD

3-27

Page 62

Decoding Laser Scanner User’s Manual Baud Rate in Data Bits per Second (continued) 4800

DE

9600*

DF

19200

DG

* Default for Serial mode.

Intercharacter Delay Some host terminals require an intercharacter delay to process information properly. The intercharacter delay simulates keystroke input by inserting a delay between transmission of characters. The delay is a certain number of milliseconds, set separately when you enable this parameter. To set the intercharacter delay 1. Scan a bar code: No Intercharacter Delay

GA

Set Intercharacter Delay

GB

2. If you select “Set Intercharacter Delay,” enter the number of milliseconds using the conversion chart in Appendix A. Note: Intercharacter Delay cannot exceed 99 ms.

3-28

Page 63

Configuring the Scanner

3

Label Buffer The label buffer controls the operation of the transmit queue by determining how labels are placed in the scanner memory before transmission and how long you must wait before scanning the next label. The buffering methods are: Full buffer Each label is read entirely and then placed in the transmit queue. Labels are transmitted immediately (unless prevented by the protocol), and you may scan the next label without waiting for the previous label to be transmitted. No buffer You cannot scan the next label until the previous one has been completely transmitted. One label buffer

You can scan ahead one label only.

Scan a bar code for the buffering method of your system: Full Label Buffer*

NE

No Label Buffer

NF

One Label Buffer

NG

* Default.

Setting Up the Bar Code Data String Each bar code is a string of data that consists of these elements: • 1 start bit • 7 or 8 data bits • 1 or 2 stop bits • Parity bits for error checking (optional) Each system and application requires different combinations of data string elements. For example, some systems require a prefix in front of the data while others do not.

3-29

Page 64

Decoding Laser Scanner User’s Manual Scan a bar code for the data string setup used with your system.

Data Setup: 1 start bit, 7 data bits, 1 stop bit Odd Parity

ED

Even Parity

EC

Mark Parity

EB

Space Parity*

EA

* Default for Serial mode.

Data Setup: 1 start bit, 7 data bits, 2 stop bit Odd Parity

EH

Even Parity

EG

Mark Parity

EF

Space Parity

EE

Data Setup: 1 start bit, 8 data bits, 2 stop bits No Parity

3-30

EN

Page 65

Configuring the Scanner

3

Data Setup: 1 start bit, 8 data bits, 1 stop bit No Parity

EM

Odd Parity

EL

Even Parity

EK

Mark Parity

EJ

Space Parity

EI

Selecting a Protocol Protocol controls data flow between the scanner and the host terminal and determines acknowledgment of data transmission between the two devices. The available protocols are: XON/XOFF Terminal sends the ASCII XON character to the scanner when it is ready to receive data, and sends the XOFF character when the buffer is full and cannot accept data. No additional hardware is needed; only transmit, receive, and signal ground are required. Clear to send (CTS) The host uses a signal that informs the scanner when it is ready to accept data. CTS (+) causes the scanner to wait for a high input level to send data. CTS (-) causes the scanner to wait for a low input level to send data. Request to send (RTS) RTS has three different operating modes: scanner sends an RTS when it is ready to receive data; RTS is set to remain fixed; and RTS sent when scanner has data to transmit.

3-31

Page 66

Decoding Laser Scanner User’s Manual Scan a bar code for the protocol for your system. XON/XOFF

HB

CTS (-)

HC

CTS (+)

HD

CTS = None. RTS high when scanner ready to receive. *

HA

Note: CTS may be programmed independently of RTS, however the polarities must match. You cannot select CTS (+) and fix RTS (-). RTS low when scanner ready to receive

HI

RTS high when scanner ready to transmit

HJ

RTS low when scanner ready to transmit

HK

RTS always high

HG

RTS always low

HH

* Default.

3-32

Page 67

Configuring the Scanner

3

Configuring the Scanner for Wand Emulation to Use With a Portable Reader You can configure your scanner for wand emulation to use it with a portable reader. To use the scanner with a portable reader 1. Scan this bar code to disable using the scanner stand: Disable Stand

NN

2. Turn off the power to the terminal before you disconnect the scanner (or remove it from the scanner stand). Otherwise, your terminal may register a scanner failure or you may cause damage to the terminal or the scanner. 3. Connect the scanner to the reader using the cables for your scanner. For help see your scanner quick reference guide. 4. Scan this bar code to set parameters: Intermec Default Wand emulation: white high 50 ips Communications: 9600, e, 7, 1

Z5

5. Scan a bar code to configure portable reader use: Select Same Code Wand Emulation

CC

Your scanner now has these default values: Parameter

Setting

Transmitted symbology

Same code and length

Bar code polarity

White

Transmission rate

50 inches per second

3-33

Page 68

Decoding Laser Scanner User’s Manual Or, Select Code 39 Wand Emulation

CB

Continue to next sections to configure for bar code conversion to Code 39 before transmission, bar code polarity, and transmission rates.

Scanning Unreadable Symbologies If the portable reader cannot process a bar code symbology, you can configure your scanner to convert to Code 39 before it transmits the data to the portable reader. To convert to Code 39 (full ASCII) before transmitting, scan this code: Transmit Code 39 only

CB

Configuring Bar Code Polarity Select one of these options for bar code polarity: Black High

WA

White High*

WB

* Default.

Configuring the Transmission Rate Select the transmission rate (in inches per second) for your portable reader by scanning one of these bar codes: 5 ips

3-34

YA

Page 69

Configuring the Scanner

3

Configuring the Transmission Rate (continued) 10 ips

YB

15 ips

YC

20 ips

YD

30 ips

YE

50 ips*

YF

70 ips

YG

* Default.

Switching Back to a Terminal To start scanning at the terminal again, scan this bar code: Note for 15XXX07 users: If your scanner is interfaced through a keyboard, scanning CA will enable Serial mode. Scan CE (next bar code) before reconnecting your scanner to the keyboard. Cancel Wand Emulation

CA

Wedge Mode Enable (for 15XXX07 scanners)

CE

Connect your scanner to the terminal or place it in the scanner stand and turn on the terminal power.

3-35

Page 70

Decoding Laser Scanner User’s Manual If your scanner does not work when you reconnect it, you may have forgotten to turn off the terminal before removing the scanner. With some terminals, this records a failure and the scanner is deactivated. To reactivate the scanner, leave it attached to the terminal, and then turn off the terminal and turn it back on again.

Configuring the Scanner for Use With an Intermec 94XX and 95XX Reader These steps are a quick way to enable wand emulation to an Intermec 94XX or 95XX reader when the scanner is connected with a “smart” cable (a cable that causes the scanner to automatically switch to Wand Emulation mode). To use the scanner with an Intermec 94XX or 95XX reader 1. Scan this bar code to reset the scanner: Reset to Default Values

ZA

2. Scan this bar code to enable wand emulation: Wand Emulation, White High

WB

3. Scan this bar code to increase the beeper volume: Beeper Volume Control (Loud)

3-36

AD