Page 171
Symbologies
4
RSS-14 On/Off Reduced Space Symbology (RSS) is a family of linear bar codes that meets restricted space requirements, while still providing full product identification. In the Other Linears tab of Visual Menu, choose RSS-14 Decoding On under RSS-14. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
4-61
Page 172
1470/1471 Imager User’s Manual
RSS-14 Limited For the default settings, see Chapter 7, “Default Charts.” In the Other Linears tab of Visual Menu, click RSS-14 Limited Default under RSS-14. Click the Write Settings to Device button (
Or scan the following bar code. Default All RSS-14 Limited Settings
4-62
) to send the new setting to the imager.
Page 173
Symbologies
4
RSS-14 Limited On/Off In the Other Linears tab of Visual Menu, choose RSS-14 Limited Code On under RSS-14. Click the Write Settings to Device button ( imager.
) to send the new setting to the
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
4-63
Page 174
1470/1471 Imager User’s Manual
RSS-14 Expanded For the default settings, see Chapter 7, “Default Charts.” In the Other Linears tab of Visual Menu, click RSS Expanded Default under RSS-14. Click the Write Settings to Device button (
Or scan the following bar code. Default All RSS-14 Expanded Settings
4-64
) to send the new setting to the imager.
Page 175
Symbologies
4
RSS-14 Expanded On/Off In the Other Linears tab of Visual Menu, choose RSS Expanded Decoding On under RSS-14. Click the Write Settings to Device button ( imager.
) to send the new setting to the
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
4-65
Page 176
1470/1471 Imager User’s Manual
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the Other Linears tab of Visual Menu, enter the minimum message length in the RSS Expanded Minimum Length field and the maximum message length in the RSS Expanded Maximum Length field under RSS-14. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
4-66
Page 177
Symbologies
4
Stacked Symbologies Stacked symbologies are multi-row linear symbologies that typically have a security algorithm. Use this section to set the parameters for the following symbologies: •
Coda Block
•
PDF 417
•
Micro PDF 417
•
Code 49
•
Composite Codes
Coda Block For the default settings, see Chapter 7, “Default Charts.” In the Matrix/Postal tab of Visual Menu, click Default under Coda Block. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan the following bar code. Default All Coda Block Settings
4-67
Page 178
1470/1471 Imager User’s Manual
Coda Block On/Off In the Matrix/Postal tab of Visual Menu, choose Decoding On under Coda Block. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20
Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15
4-68
Page 179
Symbologies
4
In the Matrix/Postal tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Coda Block. Click the Write Settings to Device button ( setting to the imager.
) to send the new
Or scan one of the following bar codes. Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
PDF 417 For the default settings, see Chapter 7, “Default Charts.” In the Stacked Linears tab of Visual Menu, click Default under PDF 417. Click the Write Settings to Device button (
) to send the new setting to the imager.
4-69
Page 180
1470/1471 Imager User’s Manual
Or scan the following bar code. Default All PDF 417 Settings
PDF 417 On/Off In the Stacked Linears tab of Visual Menu, choose Decoding On under PDF 417. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On*
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.
4-70