Page 181

Symbologies

4

Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20

Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the Stacked Linears tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under PDF 417. Click the Write Settings to Device button ( to the imager.

) to send the new setting

Or scan one of the following bar codes. Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.

4-71

Page 182

1470/1471 Imager User’s Manual

Micro PDF 417 For the default settings, see Chapter 7, “Default Charts.” In the Stacked Linears tab of Visual Menu, click Default under Micro PDF. Click the Write Settings to Device button (

) to send the new setting to the imager.

Or scan the following bar code. Default All Micro PDF 417 Settings

Micro PDF 417 On/Off In the Stacked Linears tab of Visual Menu, choose Decoding On under Micro PDF. Click the Write Settings to Device button (

4-72

) to send the new setting to the imager.

Page 183

Symbologies

4

Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On*

Off

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.

Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20

Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15 In the Stacked Linears tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Micro PDF. Click the Write Settings to Device button ( setting to the imager.

) to send the new

4-73

Page 184

1470/1471 Imager User’s Manual

Or scan one of the following bar codes. Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.

Code 49 For the default settings, see Chapter 7, “Default Charts.” In the Stacked Linears tab of Visual Menu, click Default under Code 49. Click the Write Settings to Device button (

Or scan the following bar code. Default All Code 49 Settings

4-74

) to send the new setting to the imager.

Page 185

Symbologies

4

Code 49 On/Off In the Stacked Linears tab of Visual Menu, choose Decoding On under Code 49. Click the Write Settings to Device button (

) to send the new setting to the imager.

Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On

Off*

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.

Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20

Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15

4-75

Page 186

1470/1471 Imager User’s Manual

In the Stacked Linears tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Code 49. Click the Write Settings to Device button ( to the imager.

) to send the new setting

Or scan one of the following bar codes. Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.

Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called Composite symbology. Composite symbologies allow for the co-existence of symbologies already in use.

4-76

Page 187

Symbologies

4

In the Stacked Linears tab of Visual Menu, choose Decoding On under Composite Code. Click the Write Settings to Device button ( imager.

) to send the new setting to the

Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On

Off*

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This configuration helps reduce the chances of a misread.

Example Decode only those bar codes with a count of 9-20 characters. Minimum length = 09 Maximum length = 20

Example Decode only those bar codes with a count of 15 characters. Minimum length = 15 Maximum length = 15

4-77

Page 188

1470/1471 Imager User’s Manual

In the Stacked Linears tab of Visual Menu, enter the minimum message length in the Minimum Length field and the maximum message length in the Maximum Length field under Composite Code. Click the Write Settings to Device button ( setting to the imager.

) to send the new

Or scan one of the following bar codes. Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.

4-78

Page 189

Symbologies

4

Postal Symbologies Note: For best performance when reading a postal symbology, all other postal symbologies should be turned off.

U.S. Postal Service POSTNET Code In the Matrix/Postal tab of Visual Menu, choose Postnet Decoding On under Postal Code. Click the Write Settings to Device button ( imager.

) to send the new setting to the

Or scan one of the following bar codes. The default settings are marked with an asterisk (*). On

Off*

4-79

Page 190

1470/1471 Imager User’s Manual

Planet Code In the Matrix/Postal tab of Visual Menu, choose Decoding On under Planet Code. Click the Write Settings to Device button (

) to send the new setting to the imager.

Or scan one of the following bar codes. The default settings are marked with an asterisk (*). On

Off*

British Post Office 4 State Code In the Matrix/Postal tab of Visual Menu, choose British Postal Code Decoding On under Postal Code. Click the Write Settings to Device button ( the imager.

4-80

) to send the new setting to