Symbologies
4
UPC E0/E1 For the default settings, see Chapter 7, “Default Charts.” In the UPC/EAN tab of Visual Menu, click UPC Default All under UPC. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan the following bar code. Default All UPC E0/E1 Settings
4-51
Page 162
1470/1471 Imager User’s Manual
UPC E0 On/Off Most UPC bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes that lead with the 1 number system, use the UPC E1 selection (see “UPC E1 On/Off” later in this chapter). In the UPC/EAN tab of Visual Menu, choose Version E0 Decoding On under UPC Version E. Click the Write Settings to Device button ( the imager.
) to send the new setting to
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
4-52
Off*
Page 163
Symbologies
4
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. In the UPC/EAN tab of Visual Menu, choose Version E0 Check Digit Transmit under UPC Version E. Click the Write Settings to Device button ( to the imager.
) to send the new setting
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Transmit Check Digit
Don’t Transmit Check Digit*
4-53
Page 164
1470/1471 Imager User’s Manual
Number System The numeric system digit of a UPC bar code is normally transmitted, but the imager can be programmed so it will not transmit it. In the UPC/EAN tab of Visual Menu, choose Version E0 Number System Digit Transmit under UPC Version E. Click the Write Settings to Device button ( the new setting to the imager.
) to send
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Transmit Number System
4-54
Don’t Transmit Number System*
Page 165
Symbologies
4
Version E Expand Version E Expand, expands the UPC-E code to the 12 digit, UPC-A format. In the UPC/EAN tab of Visual Menu, choose Version E0 Expand under UPC Version E. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Expand
Don’t Expand*
4-55
Page 166
1470/1471 Imager User’s Manual
UPC E1 On/Off Most UPC bar codes lead with the 0 number system. For these codes, use the UPC E0 selection (see “UPC E0 On/Off” earlier in this chapter). If you need to read codes that lead with the 1 number system, use the UPC E1 selection. In the UPC/EAN tab of Visual Menu, choose Version E1 Decoding On under UPC Version E. Click the Write Settings to Device button ( the imager.
) to send the new setting to
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
4-56
Off*
Page 167
Symbologies
4
UPC E0/E1 Addenda You can add 2 or 5 digits to the end of all scanned UPC E0 and E1 data. In the UPC/EAN tab of Visual Menu, choose Version E0/E1 2 Digit Addenda or Version E0/E1 5 Digit Addenda under UPC Version E. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default settings are marked with an asterisk (*). 2 Digit Addenda On
2 Digit Addenda Off*
5 Digit Addenda On
5 Digit Addenda Off*
4-57
Page 168
1470/1471 Imager User’s Manual
UPC E0/E1 Addenda Required When Addenda Required is used, the imager will only read UPC E0 and E1 bar codes that have addenda. In the UPC/EAN tab of Visual Menu, choose Version E0/E1 Addenda Required under UPC Version E. Click the Write Settings to Device button ( to the imager.
) to send the new setting
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Required
4-58
Not Required*
Page 169
Symbologies
4
UPC E0/E1 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. In the UPC/EAN tab of Visual Menu, choose Version E0/E1 Addenda Separator under UPC Version E. Click the Write Settings to Device button ( to the imager.
) to send the new setting
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Space
No Space*
4-59
Page 170
1470/1471 Imager User’s Manual
RSS-14 For the default settings, see Chapter 7, “Default Charts.” In the Other Linears tab of Visual Menu, click RSS-14 Default under RSS-14. Click the Write Settings to Device button (
Or scan the following bar code. Default All RSS-14 Settings