The text of a manual · part 11 of 35
1470/1471 Imager User's Manual: Chapter 3 Programming the 147X, pages 93 to 102
Pages 93 to 102 of 316, from 1470/1471 Imager User's Manual
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1470
Page 93
Programming the 147X
3
F3
Send up to but not including “ss” character (Search and Send) starting from current cursor position, leaving cursor pointing to “ss” character followed by “xx” key or function code. Syntax = F3ssxx (where ss and xx both stand for the hex values for ASCII codes, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).
F4
Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter, and nn is the numeric value [00-99] for the number of times it should be sent).
E9
Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (where nn is the numeric value [00-99] for the number of characters that will not be sent at the end of the message).
Move Commands F5
Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn (where nn stands for the numeric value [00-99] for the number of characters the cursor should be moved ahead). F6
Move the cursor back “nn” characters from current cursor position. Syntax = F6nn (where nn stands for the numeric value [00-99] for the number of characters the cursor should be moved back).
F7
Move the cursor to the beginning of the data string. Syntax = F7.
EA Move the cursor to the end of the data string. Syntax = EA
Search Commands F8
Search ahead for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F8xx (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).
F9
Search back for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F9xx (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).
E6
Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non ”xx” character. Syntax = E6xx (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).
E7
Search back for the first non “xx” character from the current cursor position, leaving cursor pointing to non ”xx” character. Syntax = E7xx (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).
3-61
Page 94
1470/1471 Imager User’s Manual
Miscellaneous Commands FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy ..zz where nn is a count of the number suppress characters in the list and xxyy .. zz is the list of characters to be suppressed. (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter.) FC Disable suppress filter and clear all suppressed characters. Syntax = FC. E4
Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2.
E5
Terminates character replacement. Syntax = E5.
FE
Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).
EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC. ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED.
3-62
Page 95
Programming the 147X
3
Data Format Editor Bar Codes Enter Data Format (see Note)
Default Data Format (None)*
Clear One Data Format
Clear All Data Formats
Note: One or more two digit numbers and Save are required after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Exit Selections Bar Codes Save Current Data Format Changes
Discard Current Data Format Changes
Data Formatter When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes). To set the Data Formatter using Visual Menu 1. Start Visual Menu. 2. Click the Data Formatting button ( ). From the Prefix/Suffix Data Formatter Control dialog box, select the Data Format tab.
3-63
Page 96
1470/1471 Imager User’s Manual
Prefix/Suffix Data Formatter Control Dialog Box
3. Under Formatter State, select either Off or On. 4. Click OK. 5. Click the Write Settings to Device button (
).
To set Data Formatter using bar codes •
Scan one of the following bar codes. The default setting is marked with an asterisk (*). On*
3-64
Off
Page 97
Programming the 147X
3
Require Data Format When Data Formatter is Required, all input data must conform to an edited format or the imager does not transmit the input data to the host device. To set Data Formatter to Required using Visual Menu 1. Start Visual Menu. 2. Click the Data Formatting button ( ). From the Prefix/Suffix Data Formatter Control dialog box, select the Data Format tab.
3. Under Formatter State, select Required. 4. Click OK. 5. Click the Write Settings to Device button (
).
3-65
Page 98
1470/1471 Imager User’s Manual
To set Data Formatter to Required using bar codes •
Scan the following bar code. Required
Show Data Formats Visual Menu displays the data formats of the connected device. Read the Show Data Formats bar code to transmit the existing data formats. One format per line is printed out. Show Data Formats
Alternate Data Formats Alternate formats allow you “single shot” capability to scan one bar code using a different data format than your primary format. When data formats are programmed, you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3. When an alternate data format is initiated, the imager will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format. To add an alternate data format using Visual Menu 1. Start Visual Menu. 2. Click the Data Formatting button ( ). From the Prefix/Suffix Data Formatter Control dialog box, select the Data Format tab.
3-66
Page 99
Programming the 147X
3
Prefix/Suffix Data Formatter Control Dialog Box
3. Click Add.
4. Choose the terminal interface you are using and click Next. 5. Choose the symbology for the alternate format and click Next.
3-67
Page 100
1470/1471 Imager User’s Manual
6. Enter the length of the code for the alternate format and click Next. 7. Choose Alternate 1, Alternate 2, or Alternate 3 and click Next. 8. Click Select Command, choose a command and enter any required information, click OK, and click Finish. 9. Click OK. 10. Click the Write Settings to Device button (
).
To initiate alternate data formats using bar codes •
Scan one of the following bar codes. Alternate Data Format 1
Alternate Data Format 2
Alternate Data Format 3
Output Sequence Overview When you turn off Required Output Sequence, the bar code data will be output to the host as the imager decodes it. When you turn on Required Output Sequence, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device. Note: This selection is unavailable when the Multiple Bar Codes Selection is turned on. Output Sequence Editor allows you to program the imager to output data (when scanning more than one bar code) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence bar code programs the imager to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence bar code.
3-68
Page 101
Programming the 147X
3
Note: To make Output Sequence Editor selections, you need to know the code ID, code length, and character match(es) your application requires. Use the Alphanumeric bar codes to read these options. For the Alphanumeric bar codes, see the “General Programming Chart” in Appendix B. To add an output sequence 1. Choose the Output Sequence tab in Visual Menu.
Or scan the Enter Sequence bar code. Enter Sequence
2. Code ID On the “Symbology Chart” earlier in this chapter, find the symbology to which you want to apply the output sequence format. Locate the hex value for that symbology. In Visual Menu, enter the two digit hex value in the Sequence field. Or scan the two digit hex value from the “General Programming Chart” in Appendix B. 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. In Visual Menu, enter the four digit data length after the Code ID in the Sequence field. Or scan the four digit data length from the “General Programming Chart” in Appendix B.
3-69
Page 102
1470/1471 Imager User’s Manual
Note: A length of 50 characters is entered as 0050. The number 9999 is a universal number, indicating all lengths. 4. Character Match Sequences On the “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter, find the hex value that represents the character(s) you want to match. In Visual Menu, enter the hex value after the Length in the Sequence field. Or use the “General Programming Chart” in Appendix B to read the alphanumeric combination that represents the ASCII characters. (The number 99 is the Universal number, indicating all characters.) 5. End Output Sequence Editor In Visual Menu, enter ff after the Character Match Sequence in the Sequence field and click the Write Settings to Device button (
).
Or scan F F to enter an Output Sequence for an additional symbology, or scan Save Current Output Sequence Changes to save your entries. Save Current Output Sequence Changes
Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the imager to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.
*A-CODE39* *A-CODE39*
B – Code 128
C – Code 93
3-70