The text of a manual · part 12 of 35
1470/1471 Imager User's Manual: Chapter 3 Programming the 147X, pages 103 to 110
Pages 103 to 110 of 316, from 1470/1471 Imager User's Manual
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1470
Page 103
Programming the 147X
3
Note: To use this example, you must turn on Code 93 start/stop characters. For help configuring Code 93, see Chapter 4, “Symbologies.” You would set up the sequence editor with the following command line: SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below: SEQBLK sequence editor start command (do not use this command in Visual Menu)
62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all lengths
41 start character match for Code 39, 41h = “A”
FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42 start character match for Code 128, 42h = “B”
FF termination string for second code
69 code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths
43 start character match for Code 93, 43h = “C”
FF termination string for third code
3-71
Page 104
1470/1471 Imager User’s Manual
Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device. When it’s On/Not Required, the imager will attempt to get the output data to conform to an edited sequence, but if it cannot, the imager transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the imager decodes it. Note: This selection is unavailable when the Multiple Bar Codes Selection is turned on.
Required
On/Not Required*
Off
Require Output Sequence cannot be set in Visual Menu.
Output Sequence Editor In the Output Sequence tab of Visual Menu, enter the digits for the output sequence followed by ff in the Sequence field and then click the Write Settings to Device button (
3-72
).
Page 105
Programming the 147X
3
Or scan one of the following bar codes. Enter Sequence (see Note)
Default Sequence*
Note: One or more two digit numbers and Save are required after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
Exit Selections Save Current Output Sequence Changes
Discard Current Output Changes
Note: If you want the imager to beep after each bar code is read, please see “Output Sequence Beeper” earlier in this chapter.
Multiple Bar Codes Note: This feature does not work when the imager is in Low Power mode. When this programming selection is turned On, it allows you to read multiple bar codes with a single pull of the imager’s trigger. If you press and hold the trigger, aiming the imager at a series of bar codes, it reads unique bar codes once, beeping (if turned on) for each read. When this programming selection is turned Off, the imager will only read the bar code closest to the aiming beam.
3-73
Page 106
1470/1471 Imager User’s Manual
In the Output Sequence tab of Visual Menu, choose Multiple Bar Codes. Click the Write Settings to Device button (
) to send the new settings to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
No Read With No Read turned On, the imager notifies you if a code cannot be read. In the QuickView Scan Data Window, an “NR” appears when a code cannot be read. For information on the Scan Data Window, see Chapter 5, “Using QuickView.” If No Read is turned Off, the “NR” will not appear. In the Output Sequence tab of Visual Menu, choose Show ‘No Read’. Click the Write Settings to Device button (
3-74
) to send the new settings to the imager.
Page 107
Programming the 147X
3
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
If you want a different notation than “NR,” for example, “Error” or “Bad Code,” you can edit the output message using the Data Formatter. The hex code for the No Read bar code is 9C.
Print Weight Print Weight is used to adjust the way the imager reads Matrix bar codes. If an imager will be seeing consistently heavily printed matrix bar codes, then a print weight of 6 may improve the reading performance. For consistently light printing, a print weight of 2 may help. A value from 0 to 7 may be used to adjust the print weight. In the Output Sequence tab of Visual Menu, enter a number from 0 to 7 in the Print Weight entry field. Click the Write Settings to Device button ( settings to the imager.
) to send the new
Or scan one of the following bar codes. The default print weight is 4. Set Print Weight (see Note)
Default*
Note: A one digit number from 1 to 7 is required after reading this programming bar code. Refer to the “General Programming Chart” in Appendix B.
3-75
Page 108
1470/1471 Imager User’s Manual
Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the imager transmits the function code to the terminal. Charts of these function codes are provided in Chapter 8, “Interface Keys.” When the imager is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. In the Output tab of Visual Menu, choose Remove Function Codes if you do not want to transmit function codes to the terminal. Click the Write Settings to Device button ( to send the new settings to the imager.
)
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On*
Off
Centering Use the centering feature to narrow the imager’s field of view to make sure that the imager reads only those codes intended by the user. For instance, if multiple codes are placed closely together, centering will ensure that only the desired codes are read. When centering is turned on, the imager only reads codes that intersect the centering window set up by the user. The window must intersect the center of the image. If a bar code is not within the predefined window, it will not be decoded or output by the scanner. If centering is turned on, the default window is a 60-pixel square area in the center of the imager’s field of view. The position of the window may be changed by scanning the window side (top, bottom, left, right) bar codes that follow and the appropriate pixel value, if other than the default, from the Programming Chart in the back of this manual. The defaults are listed in the following table.
3-76
Page 109
Programming the 147X
3
Centering Defaults Window Position
Default Minimum
Maximum Serial Command
Top of centering window
210
000
239
DECTPYxxx
Bottom of centering window
270
240
479
DECBTYxxx
Left of centering window
290
0
319
DECTPXxxx
Right of centering window
350
320
639
DECBTXxxx
The centering function can be used in conjunction with the Aimer Delay feature for the most error-free operation in applications where multiple codes are spaced closely together. Using the Aimer Delay and Centering features, the imager can emulate the operation of older systems, such as linear laser bar code scanners. Visual Menu cannot configure the Centering feature. Scan the following bar codes to configure the Centering feature. The default setting is marked with an asterisk (*). On
Off*
Top of Centering Window
Top of Centering Window Default (210)
Bottom of Centering Window
Bottom of Centering Window Default (270)
Left Side of Centering Window
Left Side of Centering Window Default (290)
3-77
Page 110
1470/1471 Imager User’s Manual
Centering Bar Codes (continued) Right Side of Centering Window
Right Side of Centering Window Default (350)
In the example below, the gray area is the full imager field of view and the white area is the centering window. Bar Code 1 will not be read, while Bar Code 2 will be.
Bar Code 1
Bar Code 2
3-78