Page 83

Programming the 147X

3

To add a CR suffix using bar codes •

Scan the following bar code if you wish to add a Carriage Return Suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. Add CR Suffix to All Symbologies

Add a Code ID Prefix to All Symbologies This selection allows you to turn on (or off) transmission of a Code ID before the decoded symbology. (For the single character code that identifies each symbology, see the “Symbology Chart” later in this chapter.) This action first clears all current prefixes, then programs a Code ID prefix for all symbologies. Add Code ID Prefix to All Symbologies

Add an AIM ID Prefix to All Symbologies This selection allows you to turn on (or off) transmission of an AIM ID before the decoded symbology. For the single character code that identifies each symbology, see the “Symbology Chart” later in this chapter. This action first clears all current prefixes, then programs an AIM ID prefix for all symbologies. Add AIM ID Prefix to All Symbologies

3-51

Page 84

1470/1471 Imager User’s Manual

Prefix Entries Bar Codes The default setting is no prefix. Add Prefix (see Note)

Clear One Prefix (see Note)

Clear All Prefixes

Note: One or more two digit numbers and Save are required after reading this programming bar code. See the “General Programming Chart” in Appendix B.

Suffix Entries The default setting is CR/LF. Add Suffix (see Note)

Clear One Suffix (see Note)

Clear All Suffix

Note: One or more two digit numbers and Save are required after reading this programming bar code. See the “General Programming Chart” in Appendix B.

3-52

Page 85

Programming the 147X

3

Exit Selections Save

Discard

Symbology Chart Symbology

Code ID

AIM ID

Hex ID

Australian 4 State

A

[X

41

Aztec Code z

[z

7A

BC412** g

[X

67

BPO 4 State

B

[X

42

Canadian 4 State

C

[X

43

Codabar a

[F

61

Codablock-F q

[O

71

Code 11 h

]H0

68

Code 39 b

[A

62

Code 49 l

[T

6C

Code 93 i

[G

69

Code 128 j

[C

6A

Code Z** u

[X

75

Data Matrix w

[d

77

EAN d

[E

64

IATA 2 of 5 f

[R

66

Interleaved 2 of 5 e

[l

65

Japanese Postal

J

[X

4A

Kix (Dutch) Postal

K

[X

4B

Maxicode x

[U

78

Micro PDF 417

R

[L

52

MSI g

]M0

67

No Read

9C

OCR o

[Y

6F

PDF 417 r

[L

72

Planet Code

L

[X

4C

3-53

Page 86

1470/1471 Imager User’s Manual

Symbology Chart (continued) Symbology

Code ID

AIM ID

Hex ID

Postnet

P

[X

50

QR Code s

[Q

73

RSS/Composites y

[e

79

UPC c

[E

63

Vericode** v

[V

76

All Symbologies***

99

Note: Prefix / Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. ** Not available in standard product. Only available when ordered in custom firmware *** All Symbologies: Prefix / Suffix programming only!

Decimal to Hex to ASCII Conversion Chart Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

0

00

NUL

32

20

SP

64

40

@

96

60

‘

1

01

SOH

33

21

!

65

41

A

97

61 a

2

02

STX

34

22

“

66

42

B

98

62 b

3

03

ETX

35

23

#

67

43

C

99

63 c

4

04

EOT

36

24

$

68

44

D

100

64 d

5

05

ENQ

37

25

%

69

45

E

101

65 e

6

06

ACK

38

26

&

70

46

F

102

66 f

7

07

BEL

39

27

‘

71

47

G

103

67 g

8

08

BS

40

28

(

72

48

H

104

68 h

9

09

HT

41

29

)

73

49 l

105

69 i

10

0A

LF

42

2A

*

74

4A

J

106

6A j

11

0B

VT

43

2B

+

75

4B

K

107

6B k

12

0C

FF

44

2C

,

76

4C

L

108

6C l

13

0D

CR

45

2D

-

77

4D

M

109

6D m

14

0E

SO

46

2E

.

78

4E

N

110

6E n

15

0F

SI

47

2F

/

79

4F

O

111

6F o

3-54

Page 87

Programming the 147X

3

Decimal to Hex to ASCII Conversion Chart (continued) Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

16

10

DLE

48

30

0

80

50

P

112

70 p

17

11

DC1

49

31

1

81

51

Q

113

71 q

18

12

DC2

50

32

2

82

52

R

114

72 r

19

13

DC3

51

33

3

83

53

S

115

73 s

20

14

DC4

52

34

4

84

54

T

116

74 t

21

15

NAK

53

35

5

85

55

U

117

75 u

22

16

SYN

54

36

6

86

56

V

118

76 v

23

17

ETB

55

37

7

87

57

W

119

77 w

24

18

CAN

56

38

8

88

58

X

120

78 x

25

19

EM

57

39

9

89

59

Y

121

79 y

26

1A

SUB

58

3A

:

90

5A

Z

122

7A z

27

1B

ESC

59

3B

;

91

5B

[

123

7B

{

28

1C

FS

60

3C

<

92

5C

\

124

7C

|

29

1D

GS

61

3D

=

93

5D

]

125

7D

}

30

1E

RS

62

3E

>

94

5E

^

126

7E

~

31

1F

US

63

3F

?

95

5F

_

127

7F

DEL

Data Format Editor Overview The Data Format Editor selections are used to edit scanned data. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. It is not necessary to use the Data Format Editor. A set of defaults for the data format is already programmed in the imager. The selections in the following pages are used only if you wish to alter the default settings. The default Data Format setting is none. To clear all data formats using Visual Menu 1. Start Visual Menu. ). From the Prefix/Suffix Data Formatter 2. Click the Data Formatting button ( Control dialog box, select the Data Format tab.

3-55

Page 88

1470/1471 Imager User’s Manual

Data Format Tab

3. Click Delete All and then click OK. 4. Click the Write Settings to Device button ( To clear all data formats using bar codes •

Scan the following bar code: Default Data Format (None)*

3-56

).

Page 89

Programming the 147X

3

To add a data format using Visual Menu 1. Start Visual Menu. ). From the Prefix/Suffix Data Formatter 2. Click the Data Formatting button ( Control dialog box, select the Data Format tab.

3. Click Add and follow the instructions through the wizard. 4. Click OK. 5. Click the Write Settings to Device button (

).

To add a data format using bar codes 1. Scan the Enter Data Format bar code. Enter Data Format

3-57

Page 90

1470/1471 Imager User’s Manual

2. Primary/Alternate Format Determine if this will be your primary data format, or one of 3 alternate formats. (Alternate formats allow you “single shot” capability to scan one bar code using a different data format. After the one bar code has been read, the imager reverts to the primary data format. For more information, see “Alternate Data Formats” later in this chapter.) If you are programming the primary format, scan 0. If you are programming an alternate format, scan 1, 2, or 3, depending on the alternate format you are programming. 3. Terminal Type Refer to the “Supported Terminals Chart” earlier in this chapter and locate the Terminal ID number for your PC. Scan three numeric bar codes on the “General Programming Chart” in Appendix B to program the imager for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. 4. Code ID From the “Symbology Chart” earlier in this chapter, find the symbology to which you want to apply the data format. Locate the hex value for that symbology and scan the 2-digit hex value from the “General Programming Chart” in Appendix B. 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the “General Programming Chart” in Appendix B. Note: A length of 50 characters is entered as 0050. The number 9999 is a universal number, indicating all lengths. 6. Editor Commands Refer to the “Format Editor Commands” later in this chapter. Scan the bar codes that represent the command you want to enter. You can enter 94 alphanumeric characters for each symbology data format. 7. Scan Save to save your entries. Save

3-58

Page 91

Programming the 147X

3

To clear or change one data format using Visual Menu 1. Start Visual Menu. ). From the Prefix/Suffix Data Formatter 2. Click the Data Formatting button ( Control dialog box, select the Data Format tab.

3. To clear a data format, select the data format you want from the list box and click Delete. To change a data format, select the data format you want from the list box, click Edit, and follow the instructions through the wizard. 4. Click OK. 5. Click the Write Settings to Device button (

).

3-59

Page 92

1470/1471 Imager User’s Manual

To clear one data format using bar codes. 1. Scan the Clear One Data Format bar code. This deletes one data format for one symbology. If you are clearing the primary format, scan 0. If you are clearing an alternate format, scan 1, 2, or 3, depending on the alternate format you are clearing. Clear One Data Format

2. Scan the Terminal Type, Code ID, and the length of the format you want to delete. To find your terminal type, see the “Supported Terminals Chart” earlier in this chapter. The length of the data format for that symbology is deleted and all other formats are unaffected. 3. Scan Save or Discard. Save

Discard

Format Editor Commands This section explains the following commands: •

Send commands

•

Move commands

•

Search commands

•

Miscellaneous commands

Send Commands

3-60

F1

Send all characters followed by “xx” key or function code, starting from current cursor position. Syntax = F1xx (where xx stands for the hex value for an ASCII code, see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).

F2

Send “nn” characters followed by “xx” key or function code, starting from current cursor position. Syntax = F2nnxx (where nn stands for the numeric value [00-99] for the number of characters and xx stands for the hex value for an ASCII code; see “Decimal to Hex to ASCII Conversion Chart” earlier in this chapter).