Page 73
Programming the 147X
3
Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, which increases data integrity. Each delay is composed of a 5-millisecond step. You can program up to 99 steps (of 5 ms each).
Intercharacter Delay Intercharacter Delay is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each character of scanned data. You can program up to 99 steps (of 5 ms each). Prefix
Scanned Data 1
2
3
4
Suffix 5
Intercharacter Delay
In the Output tab of Visual Menu, enter a value from 0 to 99 in the Intercharacter (x 5ms) field. Click the Write Settings to Device button ( the imager.
) to send the new setting to
3-41
Page 74
1470/1471 Imager User’s Manual
Or scan the Intercharacter Delay bar code below, then scan the number of steps and the Save bar code from the “General Programming Chart” in Appendix B. Note: If you make an error while scanning the digits (before scanning Save), scan Discard in the “General Programming Chart” in Appendix B, and then scan the correct digits and Save again. Intercharacter Delay
To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 00. Scan the Save bar code from the “General Programming Chart” in Appendix B.
Interfunction Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each segment of the message string. You can program up to 99 steps (of 5 ms each). Prefix STX
1
Scanned Data HT
2 3 4 5
Suffix CR
LF
Interfunction Delays
In the Output tab of Visual Menu, enter a value from 0 to 99 in the Interfunction (x 5ms) field. Click the Write Settings to Device button ( the imager.
3-42
) to send the new setting to
Page 75
Programming the 147X
3
Or scan the Interfunction Delay bar code below, then scan the number of steps and the Save bar code from the “General Programming Chart” in Appendix B. Note: If you make an error while scanning the digits (before scanning Save), scan Discard in the “General Programming Chart” in Appendix B, and then scan the correct digits and Save again. Interfunction Delay
To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 00. Scan the Save bar code from the “General Programming Chart” in Appendix B.
Intermessage Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between each scan transmission. You can program up to 99 steps (of 5 ms each).
1st Scan Transmission
2nd Scan Transmission
Intermessage Delay
In the Output tab of Visual Menu, enter a value from 0 to 99 in the Intermessage (x 5ms) field. Click the Write Settings to Device button ( the imager.
) to send the new setting to
3-43
Page 76
1470/1471 Imager User’s Manual
Or scan the Intermessage Delay bar code below, then scan the number of steps and the Save bar code from the “General Programming Chart” in Appendix B. Note: If you make an error while scanning the digits (before scanning Save), scan Discard in the “General Programming Chart” in Appendix B, and then scan the correct digits and Save again. Intermessage Delay
To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 00. Scan the Save bar code from the “General Programming Chart” in Appendix B.
Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies or only with specific symbologies. The following illustration shows the breakdown of a message string.
Prefix 1-10 alpha numeric characters
3-44
Scanned Data variable length
Suffix 1-10 alpha numeric characters
Page 77
Programming the 147X
3
Points to Keep In Mind •
It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. The default prefix is None. The default suffix is CR/LF.
•
A prefix or suffix may be added or cleared from one symbology or all symbologies.
•
You can add any prefix or suffix from the “Decimal to Hex to ASCII Conversion Chart” later in this chapter, plus Code ID and Aim ID
•
You can string together several entries for several symbologies at one time.
•
Enter prefixes and suffixes in the order in which you want them to appear on the output.
Adding a Prefix or Suffix You can add a prefix or suffix using Visual Menu or bar codes. To add a prefix or suffix using Visual Menu 1. Start Visual Menu. 2. Click the Data Formatting button ( dialog box appears.
). The Prefix/Suffix Data Formatter Control
3-45
Page 78
1470/1471 Imager User’s Manual
3. Click Add and follow the instructions in the wizard to add a prefix or suffix to a specific symbology.
To add a prefix to all symbologies, select All Symbologies from the list box and click Edit Prefix. To edit the suffix for all symbologies, select All Symbologies from the list box and click Edit Suffix. 4. Select Prefix On and Suffix On. 5. Click OK. 6. Click the Write Settings to Device button (
).
To add a prefix or suffix using bar codes 1. Scan the Add Prefix or Add Suffix bar code. Add Prefix
Add Suffix
2. Determine the 2-digit hex value from the “Symbology Chart” later in this chapter for the symbology to which you want to apply the prefix or suffix. 3. Scan the 2 hex digits from the “General Programming Chart” in Appendix B or scan 9, 9 for all symbologies.
3-46
Page 79
Programming the 147X
3
4. Determine the hex value from the “Decimal to Hex to ASCII Conversion Chart” later in this chapter for the prefix or suffix you wish to enter. 5. Scan the 2-digit hex value from the “General Programming Chart” in Appendix B. Repeat Steps 4 and 5 for every prefix or suffix character. To add the Code ID, scan 5, C, 8, 0. To add AIM ID, scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C. 6. Scan Save to exit and save, or scan Discard to exit without saving. 7. Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example Add a Suffix to a specific symbology using Visual Menu. To send a CR (carriage return) Suffix for UPC only 1. Start Visual Menu. 2. Click the Data Formatting button. The Prefix/Suffix Data Formatter Control dialog box appears. 2. Click Add. 3. Select UPC from the drop down list and click Next. 4. Select Suffix and click Next. 5. Click Control Characters, double-click CR (carriage return), and click OK. 6. Click Finish and click OK. 7. Click the Write Settings to Device button.
Clearing One or All Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. To clear one or all prefixes or suffixes using Visual Menu 1. Start Visual Menu. 2. Click the Data Formatting button ( dialog box appears.
). The Prefix/Suffix Data Formatter Control
3-47
Page 80
1470/1471 Imager User’s Manual
Prefix/Suffix Data Formatter Control Dialog Box
3. To clear one prefix or suffix from a symbology, select the symbology and click Delete, Edit Prefix, or Edit Suffix. To clear all prefixes and suffixes, select All Symbologies and click Delete, Edit Prefix, or Edit Suffix. 4. Click OK. 5. Click the Write Settings to Device button (
).
To clear one prefix using bar codes 1. Scan the Clear One Prefix bar code. Clear One Prefix
2. Determine the 2-digit hex value from the “Symbology Chart” later in this chapter for the symbology from which you want to clear the prefix or suffix.
3-48
Page 81
Programming the 147X
3
3. Scan the 2-digit hex value from the “General Programming Chart” in Appendix B or scan 9, 9 for all symbologies. Your change is automatically saved.
Add a Carriage Return Suffix to All Symbologies You can add a carriage return suffix to all symbologies using Visual Menu or bar codes. To add a CR suffix using Visual Menu 1. Start Visual Menu. 2. Click the Data Formatting button ( dialog box appears.
). The Prefix/Suffix Data Formatter Control
3. If All Symbologies appears in the list box, select All Symbologies, click Edit Suffix. From the Prefix/Suffix Data dialog box, click Control Characters, select CR, and click OK.
3-49
Page 82
1470/1471 Imager User’s Manual
Prefix/Suffix Data Dialog Box
If All Symbologies does not appear in the list box, click Add and follow the instructions in the wizard.
4. Select Suffix On. 5. Click OK. 6. Click the Write Settings to Device button (
3-50
).