Page 591
Using Remote Console
C
Field
Description
Value
Default
Communication Protocol
This box lets you specify which communication protocol you are using for remote connections.
APPC
TCP/IP and Dialup SLIP
APPC Properties
The Local node name field specifies the SNA local node name.
1 to 8 alphanumeric and special characters
ACCNET
Start Up Option
This check box determines if the controller starts the NetOp host software when it is booted.
Check, Clear
Check
To configure the NetOp host for APPC 1. In the APPC Properties box, enter the local node name of the controller. 2. In the Start-Up Option box, enable or disable the controller from automatically starting remote console when it boots. A check in the check box enables this feature. 3. Configure any security options. For help, see “Configuring Security” in the next section. 4. Choose Activate Settings. You can use the new configuration immediately.
C-7
Page 592
Model 200 Controller User’s Manual
Configuring Security The NetOp host software includes security features to prevent unauthorized access to the Model 200 Controller. You can also use the security options to limit the actions that the remote PC can perform.
C-8
Page 593
Using Remote Console
Field
Description
Value
Default
Use keyboard and mouse
This check box determines if the remote PC user can control the controller keyboard and mouse.
Check, Clear
Check
C
If this check box is clear, the remote PC user can only look at the screen on the controller. Chat
This check box determines if the remote PC user can start a chat with the controller user.
Check, Clear
Check
Send files to controller
This check box determines if the remote PC user can transfer files from the remote PC to the controller.
Check, Clear
Check
Receive files from controller
This check box determines if the remote PC user can transfer files from the controller to the remote PC.
Check, Clear
Check
Lock controller keyboard and mouse
This check box determines if the remote PC user can lock the controller keyboard and mouse during a session.
Check, Clear
Clear
Blank controller screen
This check box determines if the remote PC user can blank the controller screen during a session.
Check, Clear
Clear
Inactivity timeout after…
This check box determines if the server ends the NetOp connection if there is no activity between the remote PC and the controller.
Check, Clear
Clear
…minutes
This field specifies how long the controller waits before it ends the NetOp connection if there is no activity between the remote PC and the server.
1 to 999
10
C-9
Page 594
Model 200 Controller User’s Manual
Field
Description
Value
Default
Remote guest password
This check box determines if the remote PC user needs to enter a password after a NetOp connection is made.
Check, Clear
Clear
…password
This field contains the password the remote PC user must enter after a NetOp connection is made.
1 to 16 printable characters, except a semicolon (;)
None
Maximum attempts allowed before hangup
This field specifies the number of times the remote PC user can enter an incorrect password before the server ends the connection.
1 to 999
3
Requires password
This check box determines if you must enter a password to access this dialog box.
Check, Clear
Clear
…password
This field contains the password that you must enter to access this dialog box.
1 to 16 printable characters, except a semicolon (;)
None
Retype to confirm
You must retype the password that you entered in the Requires password field.
1 to 16 printable characters, except a semicolon (;)
None
To configure security 1. In the Remote Console Configuration dialog box, choose Security Options. The Remote Console Security Options dialog box appears. 2. Enable or disable the Use keyboard and mouse check box. A check in the check box indicates that the remote PC user can use the keyboard and mouse to access the controller. 3. Enable or disable the chat feature. A check in the check box indicates that the remote PC user can start a chat session with a controller user. 4. Enable or disable the Send files to controller check box. A check in the check box indicates that the remote PC user can send files to the controller. 5. Enable or disable Receive files from controller check box. A check in the check box indicates that the remote PC user can receive files from the controller.
C-10
Page 595
Using Remote Console
C
6. Enable or disable the Lock controller keyboard and mouse check box. A check in the check box indicates that the keyboard and the mouse of the controller are locked when a connection is made. Intermec recommends that you enable this feature. 7. Enable or disable the Blank controller screen check box. A check in the check box indicates that controller screen goes blank when a connection is made. Note: Screen update is considered an activity.
Configuring the NetOp Guest (Remote PC) For help installing the NetOp guest software, see the NetOp user’s guide that shipped with your guest software. Note: The guest communication settings must match the host communication settings; that is, they must match the communication settings on the controller.
Using NetOp Guest for Windows After you install the NetOp guest software on your remote PC, follow these tips to ensure that a connection is made. Tips for using TCP/IP 1. Choose the Call a Host PC toolbar button. The Call Host dialog box appears. 2. In the Name field, enter the IP address of the controller. 3. Choose Call. Tips for using dial-up SLIP in Windows 95 1. In the Control Panel, use the Add/Remove program to install Dial-up Networking, if it is not already installed. 2. Select the Windows Setup tab to install SLIP support. Click the Have Disk button. The files are in the ADMIN\APPTOOLS\DSCRIPT directory on your Win95 CD.
C-11
Page 596
Model 200 Controller User’s Manual
3. Create a phonebook entry. a. In My Computer folder, double-click the Dial-Up Networking icon. b. In the Dial-up Networking folder, double-click the Make a New Connection icon to create a new Dial-up Networking connection. c. Enter a name for the connection and click Next. d. Enter the phone number you want to dial and click Next. e. Click Finish to create the connection. An icon with the name of the new connection will be created in the Dial-up Networking folder. f. Right click on the connection icon just created and select Properties. g. In the General tab, press the Server Type button. h. Select SLIP as the Type of Dial-up Server and uncheck the Log on to network check box. 4. In the TCP/IP Settings dialog box, type 222.222.222.20 as the IP address. Make sure the Use IP header compression check box is unchecked. 5. Make sure that the modem that is connected to the controller is configured. 6. After the modem connection is made, start the NetOp guest software. 7. Call the TCP/IP host using the name 222.222.222.10. Tips for using dial-up SLIP in Windows NT 1. Install RAS (Remote Access Service) so that you can have dial-up networking support. 2. Create a phonebook entry. a. In My Computer folder, double-click the Dial-Up Networking icon. b. In the Dial-up Networking dialog box, click the New button to create a new phonebook entry. c. In the Basic tab, enter an entry name and the phone number you want to dial. d. In the Server tab, select SLIP as the Dial-up server type and press the TCP/IP Settings button.
C-12
Page 597
Using Remote Console
C e. In the SLIP TCP/IP Settings dialog, you must specify “222.222.222.20” as the IP address. Note: You should also uncheck the IP header compression option. 3. Make sure that the modem that is connected to the controller is configured. 4. After the modem connection is made, start the NetOp guest software. 5. Call the TCP/IP host using the name 222.222.222.10.
Using NetOp Guest for OS/2 After you install the NetOp guest software on your remote PC, follow these tips to ensure that a connection is made. Tips for using TCP/IP 1. From the Host menu, choose Add Host. The NetOp Guest - Add Host dialog box appears. 2. In the Host ID field, enter the IP address of the controller. 3. Click Settings. The NetOp Guest - Edit Host dialog box appears. 4. In the Protocol list, select TCP/IP. 5. Close all dialog boxes and then choose the Call toolbar button. Tips for using dial-up SLIP 1. Use the Network Dialer tool to make a SLIP connection to the controller. 2. In the Login Info tab, choose SLIP as the connection type. 3. In the Connect Info tab, type 222.222.222.20 as the destination IP address. 4. Make sure that the modem that is connected to the controller is configured. 5. After the modem connection is made, start the NetOp guest software. 6. Call the TCP/IP host using the name, 222.222.222.10.
C-13
Page 598
Model 200 Controller User’s Manual
Tips for using APPC 1. Use Communication Manager Setup to create a configuration file that defines the partner LU, such as the controller, that you want to control. 2. Start Communication Manager before you start the NetOp guest software. Communication Manager will use the configuration file that you defined in Step 1 as the default file.
C-14
Page 599
D Upgrading the Controller and Devices
Page 600
Model 200 Controller User’s Manual