Page 601

Upgrading the Controller and Devices

D

This appendix provides you with instructions on how to upgrade the Model 200 Controller and how to use the controller to upgrade the TRAKKER Antares terminals.

Upgrading Your Licenses When you purchased your Model 200 Controller, you selected a license that let you run a specific number of devices in your network. If you need to run more devices than what is allowed by your license, you can purchase a new license that will let the server control as many as 128 devices. You can also purchase a license that lets you run screen mapping and remote console, if your original license did not include it. These sections provide more information about terminal, screen mapping, and remote console license.

Upgrading Your Terminal License You purchase different terminal licenses depending on the number of terminals that you want to simultaneously communicate with the controller.

Level

Network Size (Number of Terminals)

1

1-8

2

1-24

3

1-64

4

1-128

The controller maintains an internal count of the number of devices that connect to it. Every time a new device is sent data, the controller increments its count. If the count reaches the maximum network size, the controller will not accept data from, nor send transactions to, any new device. The transaction is not saved and an error message appears. Each time data collection is started on the controller, the internal count is reset.

D-3

Page 602

Model 200 Controller User’s Manual

To install the license 1. From the main menu, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Terminal License Upgrade and then choose Start. The Terminal License Upgrade message box appears. 3. Insert the upgrade disk. 4. Choose OK to upgrade your terminal license. When the upgrade is complete, you return to the System Maintenance dialog box. 5. Choose Close to return to the main menu.

Upgrading to Screen Mapping You can purchase screen mapping with remote console (Part No. 067190) or without remote console (Part No. 066370). Intermec has designed an automated Script Builder Tool that lets you create custom screens and script files for your JANUS devices or TRAKKER Antares terminals. Remote console lets you manage the controller remotely. To install the license 1. From the main menu, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Screen Mapping License Upgrade and then choose Start. The Screen Mapping License Upgrade message box appears. 3. Insert the upgrade disk. 4. Choose OK to load screen mapping. When the upgrade is complete, you return to the System Maintenance dialog box. 5. Choose Close to return to the main menu.

D-4

Page 603

Upgrading the Controller and Devices

D

Upgrading to Remote Console You can purchase remote console with screen mapping (Intermec Part No. 067190) or without screen mapping (Intermec Part No. 067188). Remote console lets you manage the controller remotely. To run remote console, you also need to purchase the Intermec version of Danware’s NetOp® PC Remote Control guest software: • Remote control software for Windows™ 95 and NT (Intermec Part No. 590480) • Remote control software for OS/2 (Intermec Part No. 590478) Note: This guest software contains special software that works with the Model 200 Controller. You cannot use Danware’s commercially-available software. To install the license 1. From the main menu, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Remote Console Support and then choose Start. The Remote Console Upgrade message box appears instructing you to insert the upgrade disk. 3. Insert the upgrade disk. A message box appears confirming that you want to upgrade to remote console. 4. Choose Upgrade. When the upgrade is complete, you return to the System Maintenance dialog box. 5. Choose Close to return to the main menu.

D-5

Page 604

Model 200 Controller User’s Manual

Using the Controller to Upgrade TRAKKER Antares Terminals The Firmware Upgrade Utility lets you simultaneously upgrade the firmware on all the TRAKKER Antares terminals that the Model 200 Controller can communicate with. It detects which firmware each terminal is running and performs the correct upgrade procedure for that version. This utility also lets you install different applications on your terminals. To upgrade your terminals, you schedule upgrade events. For example, you can upgrade the firmware on one terminal now and later in the day, when no one is using the terminals, you can put a new application on all the terminals. When the events are done, you verify that the terminals were upgraded by viewing the terminal device status and the upgrade log. Before you start scheduling upgrade events, you need to determine if the firmware or application is already on the controller or is on a floppy disk that contains the new firmware or application. To see what firmware and applications are on your controller, see “Managing System Firmware and Applications” later in this appendix. To start the Firmware Upgrade Utility 1. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 2. From the System Maintenance list, choose Firmware Upgrade Utility and then choose Start. The Firmware Upgrade Utility window appears.

D-6

Page 605

Upgrading the Controller and Devices

D

In the Scheduled Firmware Upgrades box, you can view the state of all the scheduled upgrade events. Column

Description

Example

1

The date on which the upgrade event is scheduled to occur.

1997/06/14

2

The time at which the upgrade event is scheduled to occur. Time is in 24-hour format.

01:44

3

The state of the scheduled upgrade event:

Pending

Pending The utility is waiting until the scheduled date and time before starting the upgrade. Upgrading The utility is currently upgrading the devices.

D-7

Page 606

Model 200 Controller User’s Manual

Column

Description

3 (cont.)

Missed The utility was unable to perform the upgrade. The event may have been scheduled in the past or data collection was not started on the controller at the scheduled time of the upgrade event.

Example

Complete The utility successfully performed the upgrade. Errors The utility was unable to upgrade all the devices because one or more of the devices may have been unavailable at the scheduled time. The utility may have timed out or you may have stopped the upgrade on one of the devices. 4

The name of the upgrade event.

Upgrade Firmware to v2.0

Now, you need to add, edit, or delete upgrade events. For help adding upgrade events, see “Adding Upgrade Events” in the next section. To exit the Firmware Upgrade Utility 1. From the Firmware Upgrade Utility window, choose Close. You return to the System Maintenance dialog box. 2. Choose Close. You return to the main menu.

Adding Upgrade Events The Firmware Upgrade Utility lets you schedule the upgrade events or you can start the upgrade event immediately. Note: You need to use three screens to schedule an upgrade event. You can choose Back to go to a previous screen. If you choose Cancel, you return to the main Firmware Upgrade Utility window.

D-8

Page 607

Upgrading the Controller and Devices

D

To add an upgrade event 1. From the Firmware Upgrade Utility window, choose Add. The Add a New Upgrade Event to be Scheduled dialog box appears. 2. In the Event name field, enter a meaningful name for the event you are scheduling. This name can have up to 40 alphanumeric or special characters or spaces.

3. In the Firmware version field, click the down arrow on the right side of the field. A list of firmware versions that you can download appears. Choose one. Or, load the firmware from a disk that was supplied to you by your local Intermec representative or a VAR. For help, see “Loading Firmware and Applications From a Disk” later in this appendix. Or, choose <Don’t Upgrade> if you want to keep the current firmware version on your devices. 4. In the Application field, click the down arrow on the right side of the field. A list of applications that you can download appears. Choose one.

D-9

Page 608

Model 200 Controller User’s Manual

Or, load the application from a disk that was supplied to you by your local Intermec representative or a VAR. For help, see “Loading Firmware and Applications From a Disk” later in this section. Or, choose <Don’t Upgrade> if you want to keep the current application on your devices. 5. Choose Next.

6. Define logical groups of devices. All group names have a G on the right side of the name. For help, see “Defining a Group” later in this appendix. 7. Select the groups and devices that you want to upgrade. Note: You can select several sequential devices in the list box by holding down the Shift key and selecting two or more devices. You can select several individual items by holding down the Ctrl key and selecting each item. a. In the Available Groups/Devices list box, select the groups and devices that you want to upgrade. b. Choose Select.

D-10

Page 609

Upgrading the Controller and Devices

D

8. Remove any groups and devices that you do not want to upgrade. a. In the Selected Groups/Devices list box, select the groups and devices that you do not want to upgrade. b. Choose Remove. 9. In the Device time-out field, enter the number of minutes that the utility waits for the upgrade to complete on each device before it times out. If the upgrade on one of the devices does not finish before the time-out, an Error status appears next to the upgrade event name in the Firmware Upgrade utility window. 10. Choose Next.

11. In the Event Schedule box, enter the date and time that you want the upgrade event to take place. Or, use the spin buttons (up and down arrows) to select the correct Year, Month, Day, Hour, and Minute. Or, check the Immediately check box if you want the upgrade event to occur immediately after Step 12. 12. Choose Finish. You return to the Firmware Upgrade Utility window.

D-11

Page 610

Model 200 Controller User’s Manual

You are done scheduling the upgrade event. If you set a date and time for the upgrade event, a Pending status appears in the third column of the Firmware Upgrade Utility window. If you checked the Immediately check box, the utility starts upgrading the devices. Note: Before an upgrade event can happen, start data collection on the controller.

Loading Firmware and Applications From a Disk If you are ready to start scheduling upgrade events and you have received new firmware or an application from Intermec or a VAR, you can load it on your Model 200 Controller. Then you can continue scheduling an upgrade event. If you are not ready to schedule an upgrade event, but you still want to load the new firmware or application, from the Firmware Upgrade Utility window, choose Firmware. Start at Step 3 in the next procedure. To load firmware or an application on the controller 1. From the Firmware Upgrade Utility window, choose Add. The Add a New Upgrade Event to be Scheduled dialog box appears. 2. Choose Load From Diskette. This message box appears.

3. Insert the Firmware Upgrade disk in the disk drive of the controller. 4. Choose OK. The Load Firmware File Set dialog box appears. In the System on Diskette box, you can see the firmware upgrade that is available on the disk. In the Applications on Diskette box, you can see the applications that are available on the disk.

D-12