Page 581

Helpful Information

B

You can use one line to send multiple download server commands by stringing the commands together with a comma and no spaces. For example, to send a validation file, WORKORDR.TXT to device addresses pA and pB and run the program, use this command: $NGDNLD,DEV=pA,DEV=pB,F=WORKORDR.TXT,D=// To send the download server command 1. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Send Transaction and then choose Start. The Send Transaction dialog box appears. 3. If you want to emulate a request from a device, in the Source ID field enter the logical name of the device that you want to use as the source of the transaction. 4. In the Transaction ID field, enter $NGDNLD. 5. In the Data or System field, enter D. 6. In the Data field, enter the download server command. Note: If you do not enter any data in the Data field, the controller will send the source all files and data that are configured for the source. 7. Choose Send to send the transaction to the controller. The controller performs the download server command. 8. Choose Close to close the dialog box and return to the System Maintenance dialog box. 9. Choose Close to return to the main menu.

B-19

Page 582

Model 200 Controller User’s Manual

Using the Controller to Configure TRAKKER Antares Terminals You can use the Model 200 Controller to configure one or more TRAKKER Antares terminals by sending configuration commands using the download server. Note: You cannot retrieve configuration data from a terminal. For example, you may want to set the Beep Volume to very loud and turn on Keypad Caps Lock for all the terminals in one area. For a complete list of the configuration commands, see your TRAKKER Antares terminal user’s manual. To send configuration commands to a terminal, you need to perform these tasks: 1. Make sure all of the terminals are ready to receive the commands. If a terminal is not ready, the transaction is written to a Hot Standby file. 2. Use the download server to create any logical groups. For help, see “Adding a Group in the Download Server” earlier in this chapter. 3. Start data collection on the controller. 4. Download the configuration command to the terminal or group using the download server. Note: You can continue running an application on the TRAKKER Antares terminal while configuring the terminal from the controller.

B-20

Page 583

Helpful Information

B

To use the download server to configure a terminal 1. From the Terminal Download Configuration dialog box in the Terminals and Groups list box, select a terminal or group to receive files or data. 2. Choose Edit. The Configure Device Initialization Download dialog box appears.

3. In the Initialization Data box, choose Command. 4. Enter the configuration command and choose Add. The command appears in the Files and Data box. For example, to set the Beep Volume to very loud, type: $+BV4

B-21

Page 584

Model 200 Controller User’s Manual

5. Repeat Steps 3 and 4 until you have entered all the commands you want to download for this terminal or group. Commands are downloaded in the order they appear in the Files and Data list box. You can then • choose Move Up or Move Down to change the order. • select a command and choose Delete to delete a command. • start over by clearing the entire list box by choosing Clear. 6. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 7. Choose Download. The controller downloads the commands to the terminal or group. 8. Choose Close to close the dialog box and return to the System Maintenance dialog box. 9. Choose Close to return to the main menu. When you remotely configure the terminal, the commands change the terminal’s run-time configuration. The configuration changes are not saved in flash memory. You must send .+1 as the last command or use the TRAKKER Antares 2400 Menu System to save the configuration in flash memory. For help, see your TRAKKER Antares terminal user’s manual.

B-22

Page 585

C Using Remote Console

Page 586

Model 200 Controller User’s Manual

Page 587

Using Remote Console

C

This appendix explains how to use the remote console option on your Model 200 Controller. For help upgrading the controller to remote console, see “Upgrading to Remote Console” in Appendix D.

About Remote Console The remote console option lets you access the server remotely using a LAN, a WAN, or a dial-up modem. Using third-party remote control software, NetOp from Danware Data A/S, you can • access the controller GUI from a remote PC using the remote PC’s mouse and keyboard. • transfer files between a remote PC and the server. • redirect printing from the controller to a printer that is connected to the remote PC (OS/2 only). NetOp is a family of remote control products that support multiple operating systems and various communication interfaces. The software consists of two components: the host and the guest. The host is a server program that is running on the controller. The guest is a client program that you run on a remote PC. You must purchase one of these Intermec versions of the NetOp v5.3 PC Remote Control guest software: • PC Remote Control software for Windows™ 95 and NT (Part No. 590480) • PC Remote Control software for OS/2 (Part No. 590478) Note: The guest software contains special software that works with the controller. You cannot purchase commercially-available NetOp PC Remote Control software.

Configuring the NetOp Host (Model 200 Controller) The Model 200 Controller communication protocol settings must match the guest communication protocol settings; that is, they must match the communication settings on the remote PC. Use the Remote Console Configuration dialog box to configure the server. If you want to return to the default settings, choose Activate Defaults.

C-3

Page 588

Model 200 Controller User’s Manual

To configure the NetOp host for TCP/IP or dial-up SLIP 1. From the main menu, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Remote Console Support and then choose Start. The Remote Console Configuration dialog box appears. 3. In the Communication Protocol box, choose which type of communication protocol you are using to communicate with the NetOp guest software. For help with TCP/IP or dial-up SLIP, see “Configuring for TCP/IP or Dial-Up SLIP” in the next section. For help with APPC, see “Configuring for APPC” later in this chapter.

Configuring for TCP/IP or Dial-Up SLIP If you are using dial-up SLIP, you must connect a modem to the Model 200 Controller. For help, see “Connecting a Modem” in Chapter 2.

C-4

Page 589

Using Remote Console

C

Field

Description

Value

Default

Communication Protocol

This box lets you specify which communication protocol you are using for remote connections.

TCP/IP and Dialup SLIP

TCP/IP and Dialup SLIP

TCP/IP Properties

The IP address field lets you choose which IP address you are using to accept the connection.

xxx.xxx.xxx.xxx where xxx is a value between 0 and 255

First TCP/IP network adapter card

Check, Clear

Check

If you are using dial-up SLIP, choose 222.222.222.10. Start Up Option

This check box determines if the controller starts the NetOp host software when it is booted.

To configure for TCP/IP 1. In the TCP/IP Properties box, click the down arrow on the right side of the field. A drop-down list of configured IP addresses appears. Select the IP address of the network adapter card that you want to use to accept the connection. Or, to accept connections for all available IP addresses, choose All. 2. In the Start-Up Option box, enable or disable the controller from automatically starting remote console when it boots. A check in the check box enables this feature. 3. Configure any security options. For help, see “Configuring Security” later in this chapter. 4. Choose Activate Settings. You can use the new configuration immediately.

C-5

Page 590

Model 200 Controller User’s Manual

To configure for SLIP 1. In the TCP/IP Properties box, click the down arrow on the right side of the field. A drop-down list of configured IP addresses appears. Select 222.222.222.10, which is the SLIP server on the controller. 2. In the Start-Up Option box, enable or disable the controller from automatically starting remote console when it boots. A check in the check box enables this feature. 3. Configure any security options. For help, see “Configuring Security” later in this chapter. 4. Choose Activate Settings. You can use the new configuration immediately.

Configuring for APPC

C-6