Page 501

Troubleshooting

A

5. Use the vertical scroll bar on the right side of the dialog box to view your run-time configuration. 6. If you want to save the file to the controller, choose Save to Disk. 7. Choose Close to close the dialog box and return to the System Reporting dialog box. 8. Choose Close to return to the main menu.

Viewing and Clearing the Hot Standby Files You can view the contents of the Hot Standby files that the Model 200 Controller creates when it places an application or device in Hot Standby mode. The controller waits a certain period of time, which is set in the Hot Standby timeout, after delivering a transaction to an application or device to receive an acknowledgment for the transaction. If it does not receive an acknowledgment, the controller writes all transactions for the application or device to a Hot Standby file. The application or device receives its transactions from the Hot Standby file when it either sends an acknowledgment to the most recently delivered transaction or when it sends a system transaction. Before the application or device becomes interactive, it receives all the transactions from oldest to newest that are in its Hot Standby file. You can use the Clear and Clear All buttons to erase all the messages in one Hot Standby file or to erase all the messages in all the Hot Standby files. You cannot erase single messages in a Hot Standby file. Clearing the Hot Standby files can interrupt data flow and you may lose transactions. For example, if you clear a Hot Standby file while transferring a file, the transfer stops, times out, and logs an error in the error file. Also, if you clear the Hot Standby file for an application while the application is connected to the controller, the application may need to send an Inter system transaction to resume communications.

A-7

Page 502

Model 200 Controller User’s Manual

To view a Hot Standby file 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box, select View Hot Standby Files and then choose Start. The View Hot Standby Files dialog box appears.

3. Choose Update to make sure that you have the most current list. 4. Select the File Name that represents the Hot Standby file that you want to view and then choose View. The Hot Standby file appears. To clear one or more Hot Standby files 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box, select View Hot Standby Files and then choose Start. The View Hot Standby Files dialog box appears. 3. Choose Update to make sure that you have the most current list. 4. Select the File Name that represents the Hot Standby file that contains all the messages that you want to delete and then choose Clear. Or, choose Clear All to delete all the error messages in all the Hot Standby files.

A-8

Page 503

Troubleshooting

A

Message Box Error Messages These error messages may appear in message boxes on your controller display. If your error message refers to the error log, then you must view the message in the error log. Refer to the next section, “Error Log Error Messages.” This section contains all the error and event messages in alphabetical order, a brief description of the possible problem, and possible course(s) of action. If you cannot find an error message: 1. Write down the entire text of the message that is in the message box. 2. If the error message says to view the error log, open the error log. For help, see “Understanding the Error Messages” later in this chapter. Locate the error message in “Understanding the Error Messages“ later in this chapter. Check the Problem and Solution columns for information on how to correct the error messages. 3. Contact your network administrator to help you solve the problem. 4. Contact Intermec Technical Support to help you solve the problem. Note: If the % character appears in an error message in the following table, it identifies a word that is a variable depending on the context of the message box. Error Message

Solution

% is using this. You must remove all usages before it can be deleted.

You cannot delete an item until you have removed all the references for this item.

% cannot be removed from the Selected Screen list for the next screen references still exist.

You are attempting to delete a screen that is part of a next screen sequence. Unattach the screen from the sequence and try deleting the screen again.

% edit box field requires '-' or uppercase letters.

Enter a ‘-’ (dash) or use uppercase letters to enter data into the field.

% edit box field requires '@', '#', '$', or alphanumeric data type.

Enter alphanumeric or special characters in the field.

% edit box field requires 12 hexadecimal numbers.

Enter a 12-digit hexadecimal number.

A-9

Page 504

Model 200 Controller User’s Manual

Error Message

Solution

% edit box field requires 8 hexadecimal numbers.

Enter an 8-digit hexadecimal number.

% edit box field requires alphanumeric data type, beginning with an alphabet.

The first character you enter in the field must be an alpha character. The rest of the characters can be alpha or numeric.

% edit box field requires hexadecimal data type.

Enter a hexadecimal number in the field.

% edit box field requires numeric data type.

Enter a number in the field.

A device must be selected to download a terminal template file.

The controller does not know where to download the template. Select a group or device and try to download the template again.

A drive specification is not allowed.

You are trying to select a drive on the controller. Use the list box to select a specific file on the controller.

A host screen already exists with this name, enter a unique name.

Enter a unique, meaningful name for the host screen.

A host screen field already exists with this name, enter a unique name.

Enter a unique, meaningful name for the host screen field.

A host screen field has been defined with this name under the current transaction. Please re-enter or select from the drop down list.

Enter a unique, meaningful name for the host screen field or click the down arrow on the right side of the field and select a host screen field.

A host session must be selected before a connection to the session screen can be made.

Configure a host connection for the terminal session. Select a host session before choosing Start.

A name identifying the field must be entered.

You have tried to choose OK without entering a name for the transaction field. Enter a unique, meaningful name, then choose OK.

A one character string field can have a picture of X, A or Y.

You have assigned an incorrect picture to a 1-character field. You should choose X, A, or Y.

A problem occurred while saving. Try the ‘Save as’ choice with a different path.

You may be using a reserved path or filename. You do not need to enter a path. Enter your script filename.

A screen field already exists with this name, enter a unique name.

Enter a unique, meaningful name for each screen field.

A-10

Page 505

Troubleshooting

A

Error Message

Solution

A screen must be added to the menu.

You must add a screen to the menu before you can choose OK. If you do not want to add a menu, choose Cancel to exit the dialog box.

A screen with this name already exists, enter a unique screen name.

Enter a unique, meaningful name for the screen.

A Screen/Field combination is needed for mapping. This screen has no fields.

You are trying to map transaction fields to a host screen that does not contain any screen fields. Select another host screen that contains screen fields to which you can map transaction fields.

A script file must have an extension of .SCR

You are trying to save a script file without the extension .SCR. Rename the file to include .SCR.

A session must be configured for screen mapping.

You must configure a host terminal session before you can define a screen mapping session. Configure a terminal session.

A terminal template file must have an extension of .TPL

You have tried to save a template file with an incorrect extension. Save the template with the extension .TPL.

A transaction name can not begin with a %.

You have started the transaction ID with an invalid character. Use another transaction name.

An application already exists with this name, enter a unique name.

Enter a unique, meaningful name for the application.

An error occurred and was logged during the save process. ...Continue?

Choose Y to continue. View the error log. Locate the error message in “Understanding the Error Messages“ later in this chapter. Check the Problem and Solution columns for information on how to correct the error messages.

An error occurred while saving the template file. Ensure you have enough disk space to save the file.

You may not have enough room on your hard drive to save the template. Delete a template or another user file that you are not using and try saving the template again.

An error occurred while saving the trace file. Ensure you have enough disk space to save the file.

You may not have enough room on your hard drive to save the trace file. Delete a trace file or another user file that you no longer need and try saving the trace file again.

Backup failure: #%.

There is a problem with backing up your system or user files. Check your floppy disk and try again. Or, try using another disk. If the problem persists, contact Intermec Technical Support.

A-11

Page 506

Model 200 Controller User’s Manual

Error Message

Solution

Before selecting another controller, should the changes for this controller be kept or discarded?

You have configured an external Intermec controller and you have not chosen OK to save your configuration. Save or discard your changes.

Cannot convert string to a directory.

You have not selected a valid directory. Use the root directory list box to open directories and find files.

Cannot delete a host with terminals linked to it.

You are trying to delete a host that you have explicitly linked to terminals. Unlink the host and terminals and then try deleting the host.

Cannot delete the controller if the device % is linked to a host.

You are trying to delete a controller, RF card, or UDP Plus network that has devices that are explicitly linked to a host. Unlink these devices and then try deleting the controller.

Cannot download file, ensure the controller is active.

You are trying to download a file before you have started data collection. From the main menu sidebar buttons, choose Start Data Collection. Try downloading your file again.

Check the ENTIRE date or time indicated to be sure each field is complete and valid.

Refer to the online help or the user’s manual for information on valid pictures for the date or time field.

Coaxial host connection is not allowed for the 5250 terminal session. Please reenter.

You cannot configure a 5250 terminal session using a coaxial adapter card. Configure a 3270 terminal session or select another card to make the 5250 host connection.

Column value must be a number from 1 thru 80.

In the Column field, enter a value between 1 and 80.

Controller should be shutdown and restarted to fully restore backed up system files.

From the main menu sidebar buttons, choose Shutdown Controller. Enable the Save and activate check box and choose Shutdown. When the shutdown is complete, press Ctrl-AltDel to boot the controller.

Could not connect short session id %. No session information is available.

The controller cannot find all the information it needs to configure a short session ID. Check your host terminal session configuration in the GUI.

Could not initialize session parameters. No session information is available.

The controller cannot find all the information it needs to configuring a terminal session. Check your configuration in the GUI.

Could not open default configuration file.

From the main menu sidebar buttons, choose Shutdown Controller and reboot the controller. Try to restore the default configuration again.

A-12

Page 507

Troubleshooting

A

Error Message

Solution

Could not open master system file list.

From the main menu sidebar buttons, choose Shutdown Controller and reboot the controller. If the problem persists, contact Intermec Technical Support.

Could not open the migration list file.

See previous solution.

Data collection start FAILED.

From the main menu sidebar buttons, choose Shutdown Controller. Enable the save and activate check box, choose Shutdown, and reboot the controller. Try to start data collection again.

Date value does not match picture string for this field.

You have entered a date into the Value field that does not match the picture you selected for the date in the Picture field. Refer to the online help or user’s manual for valid date pictures.

Deletion failure: #%.

From the main menu sidebar buttons, choose Shutdown Controller and reboot the controller. If the problem persists, contact Intermec Technical Support.

Device missing IP Address.

All terminals in the UDP Plus network require an IP address before you can enable them for data collection. Obtain an IP address from your network administrator and enter it in the Controller Device Parameters dialog box.

ERROR - Access to drive denied

You are trying to access a drive that is unavailable. Use the root directory list box to access directories and subdirectories.

ERROR! Cannot delete the last IP Address if a UDP+ controller has been configured.

You are trying to delete the last IP address and the UDP Plus network is still valid. Delete the UDP Plus network from the controller list and then try deleting the IP address.

ERROR - Diskette is write protected

Remove the floppy disk you inserted in the floppy disk drive of the controller. Verify that the write-protect tab is in the Write position. Re-insert the floppy disk and try using it again. Or, try another disk.

ERROR - Not a DOS diskette

The disk you inserted may be configured for a Macintosh computer or it may not be configured. Remove the floppy disk you inserted in the floppy disk drive. Insert another DOS-formatted disk in the floppy disk drive and try again.

Error creating script template, dumpscrn.exe must reside on the controller

The controller cannot find the DUMPSCRN utility. From the Screen Mapping Session ID dialog box, choose Create. The DUMPSCRN window should appear. If it does not, contact Intermec Technical Support.

A-13

Page 508

Model 200 Controller User’s Manual

Error Message

Solution

Error during data collection stop, see Error Log. Stop procedure will continue...

View the error log. Locate the error message in “Understanding the Error Messages“ later in this chapter Check the Problem and Solution columns for information on how to correct the error messages.

Error retrieving field information from session %.

You are trying to use the get fields feature to create field parameters for your screen. Make sure that the host window that you are trying to get the field information from is fieldformatted.

Error selecting template file.

You have selected an invalid template. Make sure you have selected the correct template and try again.

Error spawning process, statmon.exe must reside on the controller.

The controller cannot find the status monitor program. From the main menu sidebar buttons, choose Shutdown Controller and reboot the controller. If the problem persists, contact Intermec Technical Support.

Error spawning process, trace.exe must reside on the controller.

The controller cannot find the trace program. From the main menu sidebar buttons, choose Shutdown Controller and reboot the controller. If the problem persists, contact Intermec Technical Support.

Error starting editor to modify script file.

The controller cannot find the manual editor for the script file. Intermec highly recommends that you use the Script Builder Tool to create and edit script files. From the main menu sidebar buttons, choose Shutdown Controller and reboot the controller. If the problem persists, contact Intermec Technical Support.

Error starting host terminal session, ensure the configuration has been saved and activated

Make sure that you have configured a host connection. From the main menu, choose Activate to save and activate the runtime configuration. Try starting the terminal session again.

Error starting keystroke capturing.

Make sure that you have started your host terminal session.

Error verifying script template, scrcheck.exe must reside on the controller.

The controller cannot find the script checker utility. From the Script Builder Tool, open the script that you want to check and choose Check Script. If it does not check the script, contact Intermec Technical Support.

Failure reading upgrade diskette. Upgrade aborted.

Verify that the correct upgrade disk is in the controller disk drive. Contact Intermec Technical Support.

Field position information for field %, does not correspond with defined screen size.

Select a different value for the row, column, or field length so that it will fit in the screen. Run the Terminal Session Viewer to help you see what the screen you are building looks like.

A-14

Page 509

Troubleshooting

A

Error Message

Solution

Field position values (row, column and length) will cause this field to overlap an existing field.

Run the Terminal Session Viewer so you can see where the fields on your screen are.

Field position values (row, column or length) are too large for a terminal screen.

Select a smaller value for the row, column, or field length so that it will fit in the screen. Run the Terminal Session Viewer to help you see what the screen you are building looks like.

File name must be between 1 and 8 characters in length

Enter a name that is no longer than eight characters.

Frequencies must be unique for each BRU. Please select a different frequency.

Make sure that each BRU has a different frequency, even if the BRU is not enabled.

Go to next screen was checked but one was not configured. Use the Screen button to select one.

In the Next Screen? box, you checked the Yes check box, but you did not choose the next host screen. Click the down arrow on the right side of the Name field and select a next host screen, or click New to define a new host screen.

If you delete this host, another host will be automatically selected to keep this session valid.

Make sure that you want to delete the host even though you are currently running a terminal session. If you delete the host, the controller picks another host to keep the terminal session valid.

Illegal file name, enter a valid 8.3 file name.

Contact your network administrator for a valid 8.3 file name.

Illegal picture for string field.

Refer to the online help or the user’s manual for information on valid pictures for the string field.

Input for the indicated field is incompatible with the specified data type.

Refer to the online help or the user’s manual for information on data types. Enter a valid input for the field.

Input for the indicated field is incomplete, invalid or out of range. Please re-enter.

Refer to the online help or the user’s manual for information on the value and default characters for the field. Try a new value for the field.

Input for the indicated field is required and only alphanumeric or underscore characters are allowed. Please re-enter.

You have entered an invalid entry in a required field. Try entering a new value that contains only alphanumeric characters and underscores. Do not use special characters.

Input for this numeric field must from 2147483648 through 2147483647. Please re-enter.

You have entered a number that is too large or too small for this field. Try a new number for the field.

A-15

Page 510

Model 200 Controller User’s Manual

Error Message

Solution

Invalid address format for % field.

Refer to the online help or the user’s manual for information on the field. Try a new value for the field.

Invalid data in initial value field for a numeric field.

Make sure that you select a number for numeric fields. Enter a new value.

Invalid IP address.

The format for IP addresses is yyy.xxx.xxx.xxx where yyy is from 1 to 126, 128 to 223 and xxx is from 0 to 255. Verify that you received the correct IP address from your network administrator.

Invalid picture data for a date field.

Refer to the online help or the user’s manual for information on valid pictures for date fields.

Invalid picture data for a numeric field.

Refer to the online help or the user’s manual for information on valid pictures for numeric fields.

Invalid picture data for a time field.

Refer to the online help or the user’s manual for information on valid pictures for time fields.

Invalid upgrade disk in drive.

You are trying to upgrade your terminal license or screen mapping license with an incorrect disk. Verify you have the correct disk in the controller disk drive and try again.

IP address % already in use.

You are assigning an existing IP address to a network adapter card or device. Each IP address must be unique. Enter a new IP address.

LAN adapter & protocol activate may not have completed normally. Activate halted.

You cannot activate the changes that you have made. Contact Intermec Technical Support.

Maximum length for a numeric field is 11 including '+' or '-' and '.'

You are trying to enter more than 11 characters into a numeric field. Make sure that the length of the field does not have more than 11 characters, including symbols.

Maximum number of NAU addresses used. Cannot link any more terminals to the selected host.

There are 254 NAUs available. Any NAUs in the NAU pool cannot be used to explicitly link hosts and terminals. You may be able to link more hosts and terminals by removing NAUs from the NAU pool.

Memory integrity error. Shutdown recommended.

From the main menu sidebar buttons, choose Shutdown Controller. Enable the save and activate check box, choose Shutdown, and reboot the controller.

Missing data entry for % edit box field.

You chose OK without entering information in all the required fields for the dialog box. Refer to the online help or the user’s manual to find out which fields are required.

A-16