Page 511
Troubleshooting
A
Error Message
Solution
Must have one or more entries in the % list box.
You need to add at least one item from the Available list box to the Selected list box before you choose OK. Choose Cancel to exit the dialog box.
No disk or wrong disk in drive A. Try again?
Make sure that you have the correct disk in drive A.
No field is highlighted. Please highlight a field on the VT terminal by double clicking or dragging using the mouse.
To get attributes from a VT/ANSI host screen, you must highlight the entire area on the host screen.
No terminal screen was chosen. Choose one, create a new one, or uncheck the box.
You enabled the From terminal screen check box, but did not enter which terminal screen the transaction will come from. Click the down arrow on the right side of the field and select a terminal screen or choose New and define a new one.
No transaction IDs are available to be configured for an OUTPUT transaction. You must create a new transaction ID.
You do not have any more transaction IDs to use for the output transaction for the screen. Define a new transaction ID for the screen.
Not a Controller generated System Backup diskette.
You are trying to restore the system files and runtime configuration using a disk that the controller did not generate. Verify you are using the correct disk and contact Intermec Technical Support.
One or more terminals must be configured for a group.
When configuring a group, you need to add at least one terminal from the Available Terminals list box to the Selected Terminals list box before you choose OK. Choose Cancel to exit the dialog box without creating a group.
Out of range. Valid range is 10-9999.
Enter another value between 10 and 9999 in the field.
Picture and initial value do not match, modify picture or initial value.
The prefix that you defined does not match the characters in the Picture field. Enter a new prefix or change the characters in the Picture field.
Range To value must be greater than range From value.
When specifying a numeric range, you must enter a larger number in the To field than in the From field.
Remove diskette’s protection and press OK to continue with upgrade.
The disk in drive A is write-protected. You need to remove this protection before the upgrade process can continue. Refer to your disk manufacturer’s documentation.
Restore failure: #%d
The controller cannot restore your files. Make sure your floppy disk is not write-protected. Copy your files to another disk and try again.
Row value must be between 1 and 24.
In the Row field, enter a value between 1 and 25.
A-17
Page 512
Model 200 Controller User’s Manual
Error Message
Solution
Screen fields must exist to define a screen.
You need to define screen fields for the screen before you choose OK. Choose Cancel to exit the dialog box.
Script file name cannot use illegal special characters..
You have entered a name for the script file that contains special characters that you are not allowed to use. Choose another name.
Script file name must be between 1 and 8 characters in length.
You have entered a name for the script file that is more than eight characters. Choose a shorter name.
Selected host session is already active.
You are trying to start a host session that is already active.
Specify file name only. No path or drive information is needed.
You have entered the drive and path name. Enter the filename only.
Specify static value and data type.
These are required fields. Refer to the online help or the user’s manual for information.
Stop time must be later than Start time. Please re-enter.
The stop time that you entered is earlier than the start time. Enter a new start time or stop time.
Target directory creation error.
The controller could not create the target directory. Enter a new target directory and try again. If the problem persists, contact Intermec Technical Support.
Target file must contain full file path information.
Enter the complete path name including drives, directories, and file name in the field.
Terminal emulation session is already started.
You are trying to start a host session that is already active.
Terminal session activation may not have completed normally. Activate halted.
Verify that you set all the correct terminal session parameters. Choose Shutdown Controller. Enable the Save and activate check box and choose Shutdown. When the shutdown is complete, press Ctrl-Alt-Del to boot the controller.
The 3-letter prefix entered is reserved. Please re-enter.
The controller uses a few special 3-letter prefixes. Use another unique, meaningful prefix.
The address entered is already in use.
See previous solution.
The address entered is already used by the same adapter card. Please re-enter.
Verify the address you entered. Contact your network administrator for another address.
The backup diskette created is specific to this controller. Restoring to a different controller with this diskette may cause unpredictable results.
Intermec does not recommend that you use the system backup disk in a new controller.
A-18
Page 513
Troubleshooting
A
Error Message
Solution
The cursor position is in a protected (read-only) area that is not valid for an input field. Do you want to get the field info anyway?
In 5250 field-formatted host screens there are protected fields and unprotected fields. To get attributes for a host screen field, you should place your cursor on an unprotected field.
The cursor position is in an unprotected (writeable) area that is not recommended for a screen ID. Do you want to get the field info anyway?
In 5250 field-formatted host screens there are protected fields and unprotected fields. To get the screen ID for a host screen, you should place your cursor on a protected field that contains static text.
The cursor position on the host screen is invalid.
The cursor on the host screen is positioned where you cannot get any attributes. Move the cursor to a protected or unprotected field and try getting the attributes again.
The controller must now reboot for activate to complete. Since the autostart system parameter is %.
From the main menu sidebar buttons, choose Shutdown Controller. Enable the Save and activate check box and choose Shutdown. When the shutdown is complete, press Ctrl-AltDel to boot the controller.
The controller must now reboot for this action to complete. Since the auto-start system parameter is %.
From the main menu sidebar buttons, choose Shutdown Controller. Enable the Save and activate check box and choose Shutdown. When the shutdown is complete, press Ctrl-AltDel to boot the controller.
The default value is not within the defined validation range.
You have entered a value in the Default field that is not within the range you specified.
The Define terminal prompt box is unchecked. Do you want to delete the existing prompt field %?
You have information in the Define terminal prompt box, but you have not enabled this prompt. Enable the prompt or delete the existing prompt field.
The device connection entered is already in use. Please re-enter.
Enter another device connection.
The file is empty.
You are using a file that has no contents. Verify you selected to correct file. Select another file.
The file name specified does not exist.
The controller cannot find the file that you entered. Verify that you entered the correct file name. Select another file.
The first character for a %s cannot be a numeric value.
Enter a new value that starts with an alpha character.
The Host LU entered is already in use by another adapter card. Please reenter.
Enter another unique host LU name.
A-19
Page 514
Model 200 Controller User’s Manual
Error Message
Solution
The initial value specified is longer than the defined field length.
The prefix you defined is longer than the field length. Enter a shorter prefix or a longer field length.
The Keystrokes box is checked but no keystrokes were configured.
You enabled a keystrokes check box, but you did not define the keystrokes. Make sure that you have started a host terminal session. Capture the keystrokes that you need. Refer to the online help or user’s manual.
The Local and Network ports must be unique.
You have entered the same UDP port number for the local and network ports. Enter a different port numbers for the local and network ports.
The logical name entered is already in use. Please re-enter.
Enter a unique, meaningful name for the logical name of the object.
The maximum link stations value must be between 1 and 255. Please re-enter.
Enter a value between 1 and 255 into the maximum link stations field.
The maximum Picture length is 11 including a leading sign of '+' or '-'
You are trying to enter more than 11 characters into a Picture field with a numeric data type. Make sure that the length of the field does not have more than 11 characters, including symbols.
The message cannot be deleted, it is referenced by region: %s.
You are trying to delete a message that a region sends as an action. Go to the Host Screen Region Definition dialog box and choose another action. Then, you can delete the message.
The message cannot be deleted, it is used as a screen event for tran ID: %s.
You are trying to delete a message that is being used as a screen event.
The name or label entered is already in use. Please re-enter.
Enter a unique, meaningful name for the item.
The network adapter address must be between 020000000000 and FEFFFFFFFFFF. Please re-enter.
You have entered an incorrect network adapter address. Enter another address that is a hexadecimal number between 020000000000 and FEFFFFFFFFFF.
The network adapter address must be between 400000000000 and 7FFFFFFFFFFF. Please re-enter.
You have entered an incorrect network adapter address. Enter another address that is a hexadecimal number between 400000000000 and 7FFFFFFFFFFF.
The picture field length must be less than or equal to the field length.
The value in the Picture field contains more characters than you have specified in the Length field. Enter a fewer characters in the Picture field or more characters in the Length field.
A-20
Page 515
Troubleshooting
A
Error Message
Solution
The Picture length is greater than the length specified for a Range.
The range that you specified for the field contains more characters than the number of characters that are in the Picture field. Change the range for the field or increase the number of characters in the Picture field.
The Picture value specified doesn’t match the value specified for the Range.
The range that you specified for the field contains a different number of characters than the number of characters that are in the Picture field. Change the range for the field or change the number of characters in the Picture field.
The Range value specified is longer than the defined field length.
The range that you specified for the field contains more characters than the number you defined for the length of the field. Change the length of the field or decrease the number of characters in the range.
The range values are incompatible. Change the 'from' or 'through' value.
The range that you have entered is not valid. Make sure that the value in the From field is less than the value in the To field.
The region button was checked but a valid region was not specified.
You are defining a message that requires additional text from a host screen region. You need to click the down arrow on the right side of the Region field and select a region or check the Current region check box.
The screen cannot be deleted. It is referenced by other screens or regions as the next screen.
You are trying to delete a host screen that is part of a next screen sequence. Remove the screen from the next screen sequence before you delete it.
The screen cannot be deleted. It is referenced by transaction %.
You are trying to delete a host screen that the transaction maps its fields to. Change the mapping or remove the transaction before you delete the screen.
The Screen/Field name combination is already specified. Enter a unique combination.
You can map each screen field to only one transaction field.
The selected Host cannot be deleted, it is referenced by the terminal session.
You are trying to delete a host that the controller is using for the terminal session.
The selected host session name is used by another screen mapping session.
Enter a unique, meaningful name for the host session name.
The selected screen is the main screen. You MUST uncheck the main screen attribute before removing it.
You are trying to delete a host screen that is the main host screen. Select the screen and clear the Main screen check box before you delete it.
A-21
Page 516
Model 200 Controller User’s Manual
Error Message
Solution
The selected transaction field % has already been mapped in this host screen.
You are trying to map a transaction field to a second host screen field in the same host screen.
The Send Message box is checked but no message was configured.
You enabled a check box that sends a message to the source of the transaction, but you did not define the message. Click the down arrow on the right side of the field and select a message or choose Define to define a new message.
The starting address must have the same subnet address as a currently configured ethernet card.
The IP addresses of the devices in the UDP Plus network must have the same subnet address as the Ethernet network adapter card. Verify the IP address with your network administrator.
The starting IP address plus the number of terminals to enable results in a invalid IP address.
You have entered a starting IP address that does not contain enough sequential valid IP v4 addresses for the number of UDP Plus terminals that you want to enable. Choose a new starting IP address or manually enter the terminal IP addresses.
The Subnet Address entered is already in use by another adapter card. Please re-enter.
Enter a unique subnet address for the card.
The temp file cannot be cleared since it is currently in use.
You are trying to delete a file that is currently in use. Check the contents of the file before you delete it.
The terminal screen is used by the current open script.
You are trying to delete a terminal screen that is being used by the script file.
The terminal session cannot be deleted since it is currently used for screen mapping.
You are trying to delete a terminal session that is being used by a screen mapping session. Select another terminal session for the screen mapping session. Then, you can delete the terminal session.
The total data length of a trx for a screen is limited to 254 characters. Please remove or shorten an input field.
You have created a terminal screen whose output transaction will be greater than 254 characters. Redefine your terminal screen.
The total number of screens in a menu is limited to 19. Please remove one or more screens.
You are trying to include more than 19 screens in the menu. Try combining some screens or rethinking your application definition.
The transaction can not be deleted, it is in use by %.
You need to remove the transaction from the object that is using it before you can delete it.
A-22
Page 517
Troubleshooting
A
Error Message
Solution
The transaction cannot be deleted, screen mappings exists for this screen mapping session.
You cannot delete the transaction because you have mapped its fields to screen fields. You need to remap the screen fields before you can delete the transaction.
The transaction field entered is already in use. Please re-enter.
Enter a unique, meaningful name for the transaction field.
The transaction field selected cannot be removed while it is referenced in a field mapping.
You cannot delete the transaction field because you have mapped it to a screen field. You need to remap the transaction field before you can delete it.
The transaction ID entered is already in use. Please re-enter.
Enter a unique, meaningful name for the transaction ID field.
The transaction is used by a terminal template screen definition.
You are trying to delete a transaction that is used as an output transaction for a terminal screen.
The trx field is in use for the following terminal template screen/field:
Select another transaction field to use or redefine the existing terminal screen field.
The Upper bound must be greater than the Lower bound value.
You need to enter a larger number in the Upper limit field than in the Lower limit field.
The value entered is already being used by another RF Card.
Enter a unique value.
The value string must be at least as long as the picture string.
The value that you entered in the Value field does not match the Picture field. Change the Value field or the Picture field so they match.
This group name is already in use, enter a different name.
Enter another unique, meaningful group name.
This is the only host so it cannot be deleted now. Add a new host, then retry deleting this host.
You must have at least one host configured. If you want to delete the current host, you must configure a new host. Then, you can delete the existing host.
This item is being used. You must remove all references to it before it can be deleted.
You are trying to delete an item that is being used by another item. Remove the reference to the item and then you can delete it.
Time value does not match picture string for this field.
You have entered a time into the Value field that does not match the picture you selected for the time in the Picture field. Refer to the online help or user’s manual for valid time pictures.
A-23
Page 518
Model 200 Controller User’s Manual
Error Message
Solution
Twinaxial host connection is not allowed for the 5250 terminal session using S/36 host type. Please re-enter.
You cannot configure a 5250 terminal session for an S/36 host using a twinaxial adapter card. Configure a 3270 terminal session or select another host type to make the 5250 host connection.
Unable to access file specified to fill choice lists. Check Screen Mapping Interface definition.
Verify that your terminal session and screen mapping session contains correct information. Contact Intermec Technical Support.
Unable to allocate memory for this action. Try removing unneeded items before retrying.
Try deleting any items that you do not need for your runtime configuration. Choose Shutdown controller. Enable the save and activate changes check box. Reboot your controller and Contact Intermec Technical Support.
Unable to create new script file
View the error log. Locate the error message in “Understanding the Error Messages“ later in this chapter. Check the Problem and Solution columns for information on how to correct the error messages.
Unable to create the condition list.
See previous solution.
Unable to establish communications with Message Handler. There may be another instance of it running.
Choose Shutdown Controller. Enable the Save and activate check box. Choose Shutdown Controller and then Choose Start Data Collection. If the problem persists, contact Intermec Technical Support.
Unable to load NEXTGEN configuration file (%u%u).
View the error log. Locate the error message in “Understanding the Error Messages“ later in this chapter. Check the Problem and Solution columns for information on how to correct the error messages.
Value does not match picture defined for the field.
The value that you specified for the Value field contains a different picture than the picture defined in the Picture field. Change the value in one of the fields so that the Value field and Picture field match.
VT data timeout cannot exceed the host transaction timeout (1 minute = 60000 milliseconds).
You have entered a larger value in the Data response timeout field than in the host transaction timeout. Decrease the data response timeout or increase the host transaction timeout.
You have not chosen an OUTPUT transaction ID. The default choice will be used.
The default for an output transaction ID is fieldname_tx. Enter a unique transaction ID if this one is not acceptable.
You have unsaved configuration changes. Should they be saved now or discarded?
You are closing the Script Builder tool without choosing the Save button. Choose Save to save your changes and Discard to not save your changes.
A-24
Page 519
Troubleshooting
A
Error Message
Solution
You must check one of the Region Appearing or Region Not Appearing boxes.
When you add a region, Script Builder requires that you define actions for the region appearing or not appearing. Refer to the online help or user’s manual for configuring actions.
You must configure an ethernet adapter before configuring the UDP Plus Network.
Configure at least one of your Ethernet TCP/IP cards before configuring the UDP Plus network. Refer to your online help or user’s manual.
You must create field definitions for this transaction before specifying placement information.
You need to define the transaction field for the transaction before you can give it a field position number.
You MUST select a next screen. Use the New button if you need to create a screen.
You are defining a next screen sequence, but you have not chosen a the next screen. Click the drop-down arrow on the right side of the field and select a next screen or choose New to create a new screen.
You MUST use the Current button to select a current screen before proceeding.
Script Builder needs to know the host screen for which you are defining host screen fields, regions, and messages. Select a screen from the Selected Screens list box and choose Current.
You MUST use the Current button to select a current transaction before proceeding.
Script Builder needs to know the transaction whose fields it will map to host screen fields. Select a transaction from the Selected list box and choose Current.
You MUST use the Main screen check box to select a main screen before proceeding.
Script Builder needs to know the main host screen which is the first host screen that receives all transactions for this script. Select a screen from the Selected Screens list box and enable the main screen check box.
A-25
Page 520
Model 200 Controller User’s Manual
Error Log Error Messages Error messages are generated by the Model 200 Controller. The controller sends these messages to the status monitor and to the error log.
Viewing the Error Messages The controller error messages are divided into the following parts: • The first line contains the date and time the message was generated and information about the message, including the source that generated it. The format w-xxx-yyy represents: w is the subsystem number (the controller is system 7), xxx is the module number of the source code, and yyy is the specific message number. • The second line contains the specific message. • There may be other lines that contain arguments pertaining to the error.
Example 1996-08-25 11:28:55 7-952-248 EMCOMM ERROR - The transaction Id was not found in configuration file FATAL ERROR 10 INSIDE: TEST002 FUNCTION CODE: 6 [Bad Data from Config File]
Using the Status Monitor The Status Monitor provides a run-time view of the error messages. That is, it displays the most recent error messages as they are being written to the error log file. The clock in the lower right corner of the dialog box lets you verify the exact time when the error message occurred. To view the error log 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box, select View Status Monitor and then choose Start. The Model 200 Controller Status Monitor dialog box appears.
A-26