Page 491
Using Screen Mapping
11
11. In the Terminals and Groups list box, choose the terminal or group you configured. 12. Choose Download. The template is downloaded to the terminal or group.
To request the template from the controller for the first time 1. Make sure that the host is running the application. 2. Make sure that you have started data collection on the Model 200 Controller. 3. Press
L to resume the terminal.
4. At the Enter file name? prompt, type:
template.tpl where template.tpl is the name of the template you want to run. The template main menu appears. The main menu lists all the screens you can access to send data. To request a new template from the controller 1. Make sure that the host is running the application. 2. Make sure that you have started data collection on the Model 200 Controller.
L to resume the terminal. 4. Press to request a new template.
3. Press
5. At the File name? prompt, type:
template.tpl where template.tpl is the name of the template you want to run. The template main menu appears. The main menu lists all the screens you can access to send data.
11-121
Page 492
Model 200 Controller User’s Manual
Loading a Validation File You may need to download a validation file to your terminal. The validation file performs validation on input fields in terminal screens. This file is an ASCII file that has one entry per line. Since the file is read sequentially, you should try to keep the file small. The last line of the ASCII file must be <EOF>. To load a validation file on your terminals 1. Make sure that you transfer the validation file to the controller. For help, see “Restoring Your User Files” in Chapter 2. 2. If you want to send the validation file to more than one terminal, define a group in the Download Server. For help, see “Adding a Group in the Download Server” in Appendix B. 3. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 4. Select Configure Download Server and choose Start. The Terminal Download Configuration dialog box appears. 5. In the Terminals and Groups list box, select the terminal address or group that needs the validation file. 6. Choose Edit. The Configure Device Initialization Download dialog box appears. 7. In the Initialization Data box, choose File. 8. In the field, type: \filename where filename is the filename of the validation file. 9. Clear the Binary file check box. 10. Choose Add. The file appears in the Files and Data list box with an F in the left column. 11. Choose OK to save your changes and return to the Terminal Download Configuration dialog box.
11-122
Page 493
Using Screen Mapping
11
12. In the Terminals and Groups list box, choose the terminal or group you configured. 13. Choose Download. The validation file is downloaded to the terminal or group.
To request a validation file from the controller Note: The validation file cannot have the extensions .irl, .exe, .cmd, or .img. 1. Make sure that you transfer the validation file to the controller. For help, see “Restoring Your User Files” in Chapter 2. 2. Make sure that you have started data collection on the Model 200 Controller.
L to resume the terminal. 4. Press to request a validation file.
3. Press
5. At the File name? prompt, type:
filename where filename is the name of the validation file.
Running the Application Once you have selected a screen, you can send data from the screen, reset the screen without sending data, and exit the screen. While you are entering data into screens, you may notice these events: • Data may appear in an output field that was previously empty. • A linked screen may appear if data in a field in the current screen meets some predefined value. • Data that came from a transaction that was sent to your TRAKKER Antares terminal may appear in your screen’s input fields. • A message that is sent to you from another application may appear in the system message area.
11-123
Page 494
Model 200 Controller User’s Manual
11-124
Page 495
A Troubleshooting
Page 496
Model 200 Controller User’s Manual
Page 497
Troubleshooting
A
This appendix explains the troubleshooting tools provided with your Model 200 Controller. It also lists problems and solutions for error messages that may appear in message boxes or in the error log.
General Troubleshooting These problems are general system problems that may occur while you are using the Model 200 Controller. Problem
Solution
The external Intermec controller is not communicating with the Model 200 Controller.
Make sure you have defined the correct configuration for the external controller on the Model 200 Controller. Make sure you are using the correct Intermec cable. Replace the cable. Replace the serial card.
The green LED on the Ethernet card is not lit and the card is not communicating with the network.
Make sure that your Ethernet cable is securely plugged into the card and into an Ethernet connection. The default configuration for the Ethernet card is 10BaseT. If you are using 10Base2 or 10Base5, contact your local Intermec representative. Replace the cable. Replace the card.
The green LED on the token ring card is not lit and the card is not communicating with the network.
Make sure that your token ring cable is plugged into the card and into a token ring connection. If you are connected to a 4-Mbit ring, you need to reconfigure the card. Contact your local Intermec representative.
A-3
Page 498
Model 200 Controller User’s Manual
Problem
Solution
The green LED on the RF controller card is not lit and the card is not communicating with the network.
Verify that the data collection devices are communicating. Verify that you have configured the RF card and started data collection. Make sure that all cables are securely plugged into their connections. Contact your local Intermec representative.
The external Intermec controllers are not communicating with the network.
Make sure that the configuration for the external controller in the Model 200 Controller GUI matches the configuration in the controller. Make sure that you are using the correct cables to connect your external controller to your network. Contact your local Intermec representative.
Keystrokes are not displayed in a field.
Make sure your keyboard connector is securely seated in the keyboard port on the controller. With the keyboard connected, shut down the controller and boot it. A keyboard echo failure has occurred. To release the keyboard, hold down the right-hand Alt key and press the righthand Ctrl key. Replace the keyboard.
The mouse does not work.
Make sure that your mouse connector is securely seated in the mouse port on the controller. When the controller has electrical fast transients, the mouse may not work for a short period of time. Wait a few seconds and try using it again. Replace the mouse.
A-4
Page 499
Troubleshooting
A
Using the System Reporting Tools Use these tools and features, which are available under the System Reporting sidebar button, to help you troubleshoot error conditions: View run-time configuration Shows you the active (run-time) configuration. Use this feature to determine what parameters you have defined. You can also save this file. View Hot Standby files Shows the contents of any Hot Standby files that reside on the controller. You can also erase all messages in a Hot Standby file. View Status Monitor Shows the most recent error messages as they are being written to the error log file. Message boxes and error log file The message boxes and error log file provide a list of messages pertaining to error conditions in the system and in the script. For help, see “Message Box Error Messages” and “Error Log Error Messages” later in this chapter.
Viewing the Configuration The Model 200 Controller produces a configuration file that you can view to verify the parameters that you have defined for the active configuration. To view the configuration 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box, select View Runtime Configuration(s) and then choose Start. The View Runtime Configuration Options dialog box appears.
A-5
Page 500
Model 200 Controller User’s Manual
3. Enable the configuration items that you want to view. A check in a check box will display the item in the Runtime Configuration dialog box. 4. Choose Run View. The Runtime Configuration dialog box appears.
A-6