Page 481

Using Screen Mapping

11

To use the download server to download the terminal template application 1. If you want to send the terminal template application to more than one JANUS device, define a group in the download server. For help, see “Adding a Group in the Download Server” in Appendix B. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. Select Configure Download Server and choose Start. The Terminal Download Configuration dialog box appears. 4. In the Terminals and Groups list box, select the terminal address or group that needs the terminal template application. 5. Choose Edit. The Configure Device Initialization Download dialog box appears.

6. In the Initialization Data box, choose File.

11-111

Page 482

Model 200 Controller User’s Manual

7. In the field, type: \userdata\termapps\tta\janus\rdrpgm.exe 8. Enable the Binary file check box. 9. Choose Overwrite if you want to overwrite any existing file with the same name on the JANUS devices. Do not choose Append. 10. Choose Add. The file appears in the Files and Data list box with a B in the left column. 11. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 12. In the Terminals and Groups list box, choose the terminal or group you configured. 13. Choose Download. The terminal template application is downloaded to the terminal or group.

To use Interlnk to load the terminal template application 1. Insert a 3.5-inch disk into the floppy disk drive of the controller. 2. From the main menu sidebar buttons, choose File Handling. The File Handling dialog box appears. 3. In the File Handling list box, select Back up User Files and then choose Start. The Backup User Files dialog box appears. 4. From the JANUS subdirectory, select RDRPGM.EXE and choose Select. The file appears in the Selected Files list box. 5. Choose Backup Files. The file is copied to the disk. 6. Insert the disk into a floppy disk drive of a PC. 7. Run Interlnk on the PC and your JANUS device. For help, see your JANUS user’s manual. 8. Copy RDRPGM.EXE to the E drive on the JANUS device.

11-112

Page 483

Using Screen Mapping

11

To use FTP to load the terminal template application Note: FTP commands are case-sensitive. You must type all commands in lowercase.

%3/M

1. Make sure that the JANUS device is on a writable DOS prompt. Type IPaddress

@. - . - 8 , . 4 2 and press 2. In the login name field, type @. 3. Type " # M termapps\tta\janus and then press @ . 4. Type ! ( - and press @ . 5. Type & $ 3 M 1 # 1 / & , $ 7 $ and press @. 6. When the terminal template application has finished loading on the JANUS device, type 0 4 ( 3 and press @ . where IPaddress is the IP address of the controller and press

Downloading the Template You need to download the template that was generated on the Model 200 Controller to each JANUS device that will be using screen mapping. The template is an ASCII file. Each JANUS device needs a template to run before you can enter data and send transactions. When running the template, the JANUS device prompts you for each field and it edits the data for data type, length, inclusion/exclusion in a file, and pattern matching. The controller maps the transaction fields to a host application screen. To load the template on your JANUS devices, you can • send the template to your JANUS 900 MHz RF devices if they have firmware v3.01 or later by using the download server. • send the template to your JANUS UDP Plus devices by using the download server or FTP. To use FTP, you must have an FTP client loaded on your JANUS device. • request the template from the controller by using the terminal template application that is running on your JANUS device.

11-113

Page 484

Model 200 Controller User’s Manual

To use the download server to download the template 1. Follow Steps 1 through 6 in the procedure for using the download server to download the terminal template application in “Downloading the Terminal Template Application” earlier in this chapter. 2. In the Initialization Data box field, type: \path\template.tpl where: path is the location of the template on the controller.

template is the name of the template. 3. Clear the Binary file check box. 4. Choose Add. The file appears in the Files and Data list box with an F in the left column. 5. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 6. In the Terminals and Groups list box, choose the terminal or group you configured. 7. Choose Download. The template is downloaded to the terminal or group.

To use FTP to load the template Note: FTP commands are case-sensitive. You must type all commands in lowercase.

%3/M

1. Make sure that the JANUS device is on a writable DOS prompt. Type IPaddress

@. - . - 8 , . 4 2 and press where IPaddress is the IP address of the controller and press

@

2. In the login name field, type . 3. Type

@

" # M path where path is the location of the template on the controller and press .

11-114

Page 485

Using Screen Mapping

3. Then, type

& $ 3 M template.tpl where template.tpl is the name of the template and press

04(3

11

@.

@

4. When the template has finished loading on the JANUS device, type and press . To request the template from the controller 1. Make sure that the host is running the application. 2. Make sure that you have started data collection on the Model 200 Controller.

L to resume the JANUS device. 4. On the JANUS device, load RWTSR by typing 1 6 3 2 1 and pressing @ 5. Load the Intermec RF protocol handler by typing 1 % / ' M .

3. Press

T

6. Identify the COM port that the JANUS device is using to communicate by typing SET COMPORT=IM_COM4 7. Identify the type of JANUS device you are using by typing SET READERTYPE=n where: n

900 (900 MHz) 24 (2.4 GHz)

$A%. 9. At the E prompt, type 1 # 1 / & , template.tpl 8. Change to the E directory by entering where template.tpl is the name of the template that you want to run. The template main menu appears. The main menu lists all the screens you can access to send data.

11-115

Page 486

Model 200 Controller User’s Manual

Hint You can write a batch file on the JANUS device to make it easier for the user to start the template. For example, you may want the user on shift 1 to start the template by typing his shift number at the JR2020 prompt. The batch file, SHIFT1.BAT may look like: rwtsr RFPH 4 set comport=im_com4 set readertype=900 rdrpgm shift1.tpl

Loading a Validation File You may need to download a validation file to your JANUS devices. The validation file performs validation on input fields in JANUS screens. This file is an ASCII file that has one entry per line. Since the file is read sequentially, you should try to keep the file small. The last line in the ASCII file must be <EOF>. To load a validation file on your JANUS devices, you can • load the file on the DCS 300 and send the file to a JANUS device by using the download server. • load the file on the DCS 300 and send the file to a JANUS UDP Plus device by using the download server or FTP. To use FTP, you must have an FTP client loaded on your JANUS device. • run Interlnk on the PC and a JANUS device.

11-116

Page 487

Using Screen Mapping

11

Running the Application Once you have selected a screen, you can send data from the screen, reset the screen without sending data, and exit the screen. While you are entering data into screens, you may notice these events: • Data may appear in an output field that was previously empty. • A linked screen may appear if data in a field in the current screen meets some predefined value. • Data that came from a transaction that was sent to your JANUS device may appear in your input fields on the screen. • A message that is sent to you from another application may appear in the system message area. To enter data into a screen 1. From the menu, use the want to enter data.

C and E keys to select the screen in which you

H

2. Press . The screen you selected appears on the JANUS display and the screen name is in the title bar. 3. Type or scan data into the fields. Use the accept the data for each field.

C and E or press @ to

4. When you have finished filling in the fields: • If Auto send was chosen when the screen was defined, the transaction is automatically sent to the controller.

G to send the transaction to the controller. • Press I to reset the screen and reposition the cursor to the first input field without sending the data. • Press K to exit the screen without sending the data and return to the • Press main menu.

11-117

Page 488

Model 200 Controller User’s Manual

Configuring Your TRAKKER Antares Terminals With the Model 200 Controller, you can run screen mapping between your remote host and your TRAKKER Antares terminals.

Configuring the Terminals for the First Time Before the terminal can communicate with the Model 200 Controller, you need to configure each terminal. On the T2425, press to access the TRAKKER Antares 2400 Menu System. On the T248X, press to access the TRAKKER Antares 2400 Menu System. For help, see your TRAKKER Antares terminal user’s manual. You need to set these parameters on each terminal:

S3,

• Time and date • Network activate • Network port (must match the Model 200 Controller) • Controller IP address (must match the Model 200 Controller) • Terminal IP address • RF domain (same as the access point) • RF security identification (same as the access point) The terminal also needs to know where to send transactions. Choose one of these options: • Explicitly link the terminals to a host. For help, see “Configuring the Controller” in Chapter 8. • Identify a host name on each terminal. To set the host name, you access the TE Configuration menu by pressing and then on the terminal when the TE welcome screen is displayed on the terminal. You can also access the TE Configuration menu by pressing the same key sequence once a terminal session is established. For help, see your TRAKKER Antares terminal user’s manual.

Note: You cannot enter the TE Configuration Menu when the terminal is trying to connect to the Model 200 Controller.

11-118

Page 489

Using Screen Mapping

11

Downloading the Template You need to download the template that was generated on the Model 200 Controller to each TRAKKER Antares terminal that will be using screen mapping. The template is an ASCII file. Each terminal needs a template to run before you can enter data and send transactions. When running the template, the terminal prompts you for each field and it edits the data for data type, length, inclusion/exclusion in a file, and pattern matching. The controller maps the transaction fields to a host application screen. You can load the template on your terminals by • sending the template to your terminals using the download server. • requesting the template from the controller using the terminal template application running on your terminal. To use the download server to download the template 1. If you want to send the template to more than one terminal, define a group in the Download Server. For help, see “Adding a Group in the Download Server” in Appendix B. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. Select Configure Download Server and choose Start. The Terminal Download Configuration dialog box appears. 4. In the Terminals and Groups list box, select the terminal address or group that needs the template. 5. Choose Edit. The Configure Device Initialization Download dialog box appears.

11-119

Page 490

Model 200 Controller User’s Manual

6. In the Initialization Data box, choose File. 7. In the field, type: \tpl\template.tpl where template.tpl is the name of the template that you want to download. 8. Clear the Binary file check box. 9. Choose Add. The file appears in the Files and Data list box with an F in the left column. 10. Choose OK to save your changes and return to the Terminal Download Configuration dialog box.

11-120