Page 471

Using Screen Mapping

11

Adding a Menu

To add a menu 1. From the Menu List dialog box, choose Add. The Menu Items dialog box appears. 2. In the Menu name field, enter a name for the group of screens you are selecting that you will generate into a template. 3. In the Selected Screens list box, add screens to the menu by selecting a screen in the Available Screens list box and choosing Add. 4. In the Selected Screens list box, remove screens from the menu by selecting the screen and choosing Remove. 5. Choose OK to save your changes and return to the Menu List dialog box.

11-101

Page 472

Model 200 Controller User’s Manual

Generating Menus Into Templates When you have built the menus from the screens, you need to generate them into terminal templates. Each menu generates into one terminal template. You can use the download server feature to download this terminal template to your data collection devices or you can use the reader program on your devices to request it. For help, see “Configuring Your JANUS Devices” and “Configuring Your TRAKKER Antares Terminals” later in this chapter. To generate a terminal template 1. From the Script Builder Tools window, choose Terminal Template. 2. Choose Generate Templates. The Generate Template dialog box appears.

3. In the Menu name field, click the down arrow on the right side of the field. A list of the menus that you have created appears. Select the menu that you want to generate into a terminal template. 4. In the Template file name field, click the down arrow on the right side of the field. A list of existing terminal template filenames appears. Select the terminal template you want. Or, enter a new terminal template filename. The default value is the first eight characters of the menu name with a .TPL extension. 5. Choose OK. The menu is generated into a terminal template that you download to your devices.

11-102

Page 473

Using Screen Mapping

11

Saving and Activating Your Run-Time Configuration When you finish configuring screen mapping, you should save your changes. If you are done configuring the controller, activate your run-time configuration. When the activate is complete, a message box appears if you need to reboot the controller. To save and activate your run-time configuration 1. From the main menu sidebar buttons, choose Save and Activate. The Activate Configuration message box appears. 2. Choose Activate. The controller saves your run-time configuration to disk and it becomes your active configuration. If you are ready to start data collection, from the main menu sidebar buttons, choose Start Data Collection.

Script Builder Tool Limitations Validation can be performed by the data collection device or the host application. The script cannot perform any validation. The Script Builder Tool cannot generate these commands: ACK_MESSAGE

IF_BATCH

SEARCH_SCREEN

AUDIT

IF_SEARCH

USER_INPUT

CAPTURE_POS

LOG_ERROR

WAIT_FOR_POS

FILL_FIELD

PAUSE

WAIT_FOR

IF_

PUT_MAPPED_TRANS

WAIT_FOR_LABEL_POS

If you need to use these commands, you can define a user block to insert these commands into the script. For help, see “Defining User Blocks” earlier in this chapter.

11-103

Page 474

Model 200 Controller User’s Manual

PUT_TRANS_FIELD generates is:

The format of this command that the Script Builder Tool

PUT_TRANS_FIELD transactionfieldnumber fieldlabel where: transaction field number is the position of the field in the transaction.

field label is the name of the host screen field you want to map to the transaction field.

In the DCS 300 Technical Reference Manual, there are two optional parameters following the field label that allow you to map partial data to a host field. The Script Builder Tool does not support partial data mapping. These parameters are: SEND_MESSAGE

There are two types of messages: status and transaction.

For status messages, the format of this command that the Script Builder Tool generates is: SEND_MESSAGE "TERM_MESSAGE," + userdefinedtext + [regionlabel | CUR_POS | CUR_ROW] SRC Status messages always starts with “TERM_MESSAGE,” which is automatically generated. The destination is always fixed to SRC, the source of the transaction, which is assumed to be an Intermec terminal. The SRC can only receive the message if the Wait for response check box is checked in the Terminal Screen and Fields dialog box. For transaction messages, the format of this command that is generated by Script Builder Tool is: SEND_MESSAGE userdefinedtext + [regionlabel | CUR_POS | CUR_ROW] SRC The user-defined text contains data in the format of a transaction and again the destination is fixed to SRC. This type of message is delivered to the source of the transaction and the transaction data is mapped to the terminal screen according to the terminal template definition. In the DCS 300 Technical Reference Manual, the SEND_MESSAGE command lets you specify a destination other than SRC. You can also have as many concatenations as you want, as long as the string does not exceed the maximum line length. If the Script Builder Tool generates the SEND_MESSAGE command, you are restricted to these formats.

11-104

Page 475

Using Screen Mapping

11

CURRENT_SCREEN The Script Builder Tool generates this command and places it as the first line of every set of events for each transaction. The screen label for this command is the main screen, since every set of events for each transaction starts from processing the main screen events. You cannot control where this command appears in the script.

VT/ANSI Screen Mapping Limitations VT/ANSI terminals have some limitations that affect how you can use screen mapping. However, if you are having problems because of a limitation, you can use the WAIT_FOR scripting command. For help, see the DCS 300 Technical Reference Manual. • You cannot automatically position the host cursor to the host screen field in VT/ANSI screen mapping. However, you can program the script to wait until the cursor is at the field using the WAIT_FOR command. To move the host cursor to the desired host screen field, you add keystrokes, such as NEWLN, to the script. When you define a host screen field in Script Builder, you can define an exit keystroke that will be applied after field mapping. If the exit field keystroke will not move the host cursor to the next host screen field, you can define keystrokes using the user block feature. Make sure that you add these keystrokes before the PUT_TRANS_FIELD command for the next field. • When the host VT/ANSI screen is in Scroll mode and the host is using pseudo field-formatted screens, the server does not know where to put the data on the host screen. You must use the script WAIT_FOR commands so the server knows when the host is done sending data. • VT terminal sessions and the VT windows that are displayed on the controller screen cannot show blinking text. If the host application sends blinking text to a VT terminal session, the controller shows the text as white text on a dark red background. If it sends blinking text to a VT window, the controller shows the text as green text on a black background.

11-105

Page 476

Model 200 Controller User’s Manual

VT Keyboard Mapping and Script Keystroke Names This table shows how VT keyboard keys map to the Model 200 Controller keyboard and to the script keystroke names. For a diagram of how the VT keyboard maps to the controller keyboard, see Chapter 8, “Using Terminal Emulation.”

11-106

VT Keyboard

Controller Keyboard

Script Name

Enter (keypad)

Enter (keypad)

ENTER

, (keypad comma)

+ (keypad plus)

CLEAR

Not used

Not used

LTAB

Tab

Tab

RTAB

Delete

Backspace

DEL

Ctrl-H

Shift-Backspace

BACKSP

Insert

Insert

INS

- (keypad minus)

Shift-+ (keypad plus)

ERS_EOF

Cursor left

Cursor left

CUR_LFT

Return

Enter (keyboard)

NEWLN

Spacebar

Spacebar

SPACE

Not used

Not used

RESET

Cursor up

Cursor up

CUR_UP

Cursor down

Cursor down

CUR_DN

Cursor right

Cursor right

CUR_RT

Find

Home

HOME

PF1

Num Lock

PF1

PF2

/ (keypad forward slash)

PF2

PF3

* (keypad asterisk)

PF3

PF4

- (keypad minus)

PF4

Not used

Not used

PF5

F6

F6

PF6

F7

F7

PF7

Page 477

Using Screen Mapping

11

VT Keyboard Map (continued) VT Keyboard

Controller Keyboard

Script Name

F8

F8

PF8

F9

F9

PF9

F10

Alt-F10

PF10

F11

Shift-F1

PF11

F12

Shift-F2

PF12

F13

Shift-F3

PF13

F14

Shift-F4

PF14

F15/Help

Shift-F5

PF15

F16/Do

Shift-F6

PF16

F17

Shift-F7

PF17

F18

Shift-F8

PF18

F19

Shift-F9

PF19

F20

Shift-F10

PF20

0 (keypad 0)

0 (keypad 0)

PF21

1 (keypad 1)

1 (keypad 1)

PF22

2 (keypad 2)

2 (keypad 2)

PF23

3 (keypad 3)

3 (keypad 3)

PF24

4 (keypad 4)

4 (keypad 4)

END

Prev Scrn

Page up

PAGEUP

Next Scrn

Page down

PAGEDN

Select

End

PA1

Remove

Delete

PA2

Ctrl-[

Esc

PA3

5 (keypad 5)

5 (keypad 5)

TEST

6 (keypad 6)

6 (keypad 6)

SYSREQ

7 (keypad 7)

7 (keypad 7)

ATTN

11-107

Page 478

Model 200 Controller User’s Manual

VT Keyboard Map (continued) VT Keyboard

Controller Keyboard

Script Name

8 (keypad 8)

8 (keypad 8)

FLDPLUS

9 (keypad 9)

9 (keypad 9)

FLDMINUS

. (keypad decimal point)

. (keypad decimal point)

FLDEXIT

Keystrokes A keystroke can be a mnemonic or a string. The table below lists the 3270 and 5250 keystroke mnemonics supported by the controller.

11-108

Key

Mnemonic

Key

Mnemonic

Enter

ENTER

Cursor Right

CUR_RT

Left Tab

LTAB

Cursor Left

CUR_LFT

Right Tab

RTAB

System Request

SYSREQ

Clear

CLEAR

Reset

RESET

Delete

DEL

Page Up

PAGEUP

Insert

INS

Page Down

PAGEDN

New Line

NEWLN

Attention

ATTN

Space

SPACE

Field Exit

FLDEXIT

Home

HOME

Erase EOF

ERS_EOF

End

END

Test

TEST

Cursor Up

CUR_UP

No Keystroke

NONE

Cursor Down

CUR_DN

PA1, PA2, PA3

PA1, PA2, PA3

Function Keys F1 - F24

PF1 - PF24

Page 479

Using Screen Mapping

11

Configuring Your JANUS Devices Your Model 200 Controller lets you perform screen mapping between your remote host and your JANUS devices.

Configuring Communications You need to configure each JANUS device for 900 MHz RF or 2.4 GHz RF communications. Run the Interactive Configuration application (IC.EXE) on your JANUS device to set the parameters for the environment it will be used in. For help using IC.EXE, refer to your JANUS user’s manual.

Configuring for 900 MHz RF Communications 1. In the Com menu, choose RF and press

@.

2. Choose Activate. 3. In the RF Protocol field, select Enabled. 4. Choose Primary Cfg. 5. In the Device Address field, enter the address of the JANUS device. This address must match an address that is enabled in the Model 200 Controller. 6. Configure the Channel Select and the Network ID. 7. In the File menu, choose Exit. 8. Choose Yes to save your configuration.

Configuring for UDP Plus Communications You need to configure each JANUS 2.4 GHz RF device for UDP Plus communications. Run the JANUS 2.4 GHz Installation Utility to configure each device and install the network software. For help, see the JANUS 2.4 GHz Installation Utility User’s Manual. Note: If the access points are using a security ID, you must set the same security ID on the JANUS devices.

11-109

Page 480

Model 200 Controller User’s Manual

Downloading the Terminal Template Application You need to download the terminal template application (RDRPGM.EXE) from the Model 200 Controller to each JANUS device that will be using screen mapping. This application allows the JANUS device to run the templates for screen mapping. Depending on the type of communications your JANUS devices are using and which firmware version is loaded, you can load the terminal template application on your JANUS devices using one of these methods: • If your JANUS 900 MHz RF device has firmware v3.01 or later, use the download server feature. Note: Your JANUS devices must have FTA.EXE and FTA.INI loaded on drive C. Copy these files from Application companion disk 3. For help, see your JANUS user’s manual. Note: Your JANUS devices must be running a BFT-ready PSK application. • If your JANUS 900 MHz RF device has an earlier firmware version than 3.01, use Interlnk. • If your JANUS 2.4 GHz RF device is using UDP Plus, use the download server or FTP. To use FTP, you must have an FTP client loaded on your JANUS device.

11-110