Page 461
Using Screen Mapping
11
Field
Description
Value
Default
Field name
A unique identifier for the terminal field.
1 to 16 alphanumeric characters
None
Row
The row position that indicates where the field starts on the terminal screen.
1 through 25, based on screen size selected
1 or the next available row.
Column
The column position that indicates where the field starts on the terminal screen.
1 through 80 based on screen size selected
1
Type
The type of field. Fixed fields are always the same value. Input fields accept input from the user. Output fields display information only.
Fixed, Input, Output
Fixed
11-91
Page 462
Model 200 Controller User’s Manual
Field
Description
Value
Default
Data type
The type of data that you can enter into this field.
Date, Time, Numeric, String
String
Attribute
The physical attributes of the data type field.
Blink, Hidden, Inverse, None
None
Length
The maximum length of the field.
String is 1 to 80
5
Numeric is 1 to 11 including a sign (+ or -) and a decimal point. Trx field number
The position of the field in the transaction sent by this screen.
1 to 9999
None
Required
This check box indicates if the field is required to be filled in before the user can proceed to another screen.
Check, Clear
Check
Picture
The character-by-character validation string for an input field.
X - any character A - alpha only 9 - numeric only Y - Yes/No
XXXXX
Special characters Value
The default value for an input field or the value for a fixed field.
None
None
To add a terminal field 1. From the Terminal Screen and Fields dialog box, choose Add. The Screen Field Parameters dialog box appears. 2. In the Field name field, enter the unique name for the terminal field. 3. In the Origin box, define the row and column of the upper left corner of the field. 4. In the Field box, define the type, data type, length, picture, and default value. 5. In the Attribute field, click the down arrow on the right side of the field. A list of attributes appears. Choose the attribute you want to use for the Data type field.
11-92
Page 463
Using Screen Mapping
11
6. Enable or disable the Required check box that determines if this field is required. A check in the check box means that this field is required. 7. In the Trx field number field, enter the order or position (for example, 1, 2, or 3) of this field in the transaction that the screen sends. Fields start at 1. 8. If you want validation performed on an input field, choose Validation. The Screen Field Validation dialog box appears. For help, see “Validating a Terminal Field” later in this chapter. 9. Choose OK to save your changes and return to the Screen Definition dialog box.
Validating a Terminal Field
11-93
Page 464
Model 200 Controller User’s Manual
Field
Description
Value
Default
Range
Enable or disable checking the field against a numeric range.
Enable, Disable
None
From
The beginning numeric value in the range.
-999999999 to 9999999999
None
To
The ending numeric value in the range.
-9999999999 to 99999999999
None
File
The name of the file on the terminal that contains valid values. Data entered in the input field is validated against these values.
Enable, Disable
None
Prefix
The characters that the data in an input field must begin with or not begin with to be valid.
1 to 6 characters
None
None
This option button indicates that no validation will occur on the field.
None
None
Valid if
These option buttons indicate that the value in the input field is valid if it is included or excluded in the range or file.
Included, Excluded
Included
To validate a terminal field 1. From the Screen Field Parameters dialog box, choose Validation. The Terminal Screen Field Validation dialog box appears. 2. In the Field box, make sure that you are configuring validation for the correct field. 3. In the Check against box, choose the type of validation you want to perform on the field. 4. Enter the range, file, or prefix. Note: If you choose a decimal range, the value becomes a sign (+,-) a decimal point, and nine numbers.
11-94
Page 465
Using Screen Mapping
11
5. Choose if the data in the input field is included or excluded in the range or file. 6. Choose OK to save your changes and return to the Screen Field Parameters dialog box.
Getting Terminal Field Attributes From a Host Screen In 5250 field-formatted host screens, there are two types of fields: protected and unprotected. To get terminal field attributes from a host screen field, position the host cursor anywhere in a protected or an unprotected field and then choose Host Session. The Script Builder fills in the Type, Data type, Attribute, Length, Picture, and Value (if any string exists) fields. 3270 field-formatted host screens do not differentiate between protected and unprotected fields. To get terminal field attributes from a host screen field, position the host cursor at the beginning position of a field and then choose Host Session. The Script Builder fills in the Type, Length, Picture, and Value (if any string exists) fields. VT/ANSI host screens are not field-formatted host screens. To get host screen field attributes from a host screen field, you must highlight the entire host screen field before you choose Host Session. If nothing is selected when you choose Host Session, an error message occurs. To get terminal field attributes from a host screen field 1. Start a temporary host session. For help, see “Starting a Host Session” in Chapter 10. 2. In the host window, open the host screen that contains fields you are using to build the terminal screen. 3. In the host window, place your cursor on the field whose attributes you want to use for the terminal screen field. 4. In the Terminal Screen and Fields dialog box, choose Host Session. The Origin, Field, and Value boxes are populated with the attributes of the host screen field. 5. If necessary, edit the information in the fields.
11-95
Page 466
Model 200 Controller User’s Manual
6. Choose OK to save your changes and return to the Screen Definition dialog box. 7. Repeat Steps 3 through 6 until you have added all the fields from the host window to the terminal screen.
Getting Terminal Field Attributes From the Script File You can get terminal field attributes from a defined host screen field in the script file. To get terminal field attributes from a script file 1. In the Script Builder Tools window, open a script file you will use with the template. 2. From the Script Builder Tools window, choose Terminal Template. 3. Choose Build Screen. The Build Screen List dialog box appears. 4. In the Screen list box, select the screen that contains the terminal field whose attributes you want to define and then choose Edit. The Terminal Screen and Fields dialog box appears. 5. In the Transaction field, click the down arrow on the right side of the field. A list of the available transactions appears. Choose the transaction ID of the transaction that is created by this screen. 6. Choose Screen Mapping. For each of the transaction fields, the Script Builder Tool checks to see if a host screen field is mapped to it. The Script Builder Tool then checks to see if a terminal field is mapped to that transaction field. If a terminal field does not exist, it automatically creates one from the host screen field definition. The new terminal field has a field type of input and is added to the next row on the terminal screen.
11-96
Page 467
Using Screen Mapping
11
Defining Next Screen Sequence for Terminal Screens This feature lets you identify a linked screen to appear on the terminal when a condition is met after you send a screen transaction. When you set up a Next screen, the terminal compares data in the selected Screen field to a value in the Value field. If the logic is true, then the Next screen appears on the terminal. • If you want the screen in the Next screen field to appear when specific data is entered in the screen field, use the Operator and Value fields to create the logic that determines when the linked screen appears. • If you want the screen in the Next screen field to always appear after the user sends the current screen transaction, you need to make the Screen field a required field in the Screen Field Parameters dialog box. Then choose the operator to be NOT BLANK. You do not have to enter a value in the Value field.
11-97
Page 468
Model 200 Controller User’s Manual
Field
Description
Value
Default
Screen field
The field from the current screen whose data is compared to the Value field. The results of the comparison determine whether or not the screen in the Next field appears.
Predefined
None
Operator
The list of valid operators that you can use to compare the Screen field against the Value field.
=, >, <, !=, >=, <=, BLANK, NOT BLANK
=
Value
The value that is compared to the data in the Screen field that determines whether or not the screen in the Next field appears.
None
None
Next
The name of the screen that is displayed if the Screen field and Value logic is true.
Predefined
None
To configure a next screen 1. From the Terminal Screen and Fields dialog box, choose Screen. The Next Screen dialog box appears. 2. Make sure that the Current screen field contains the original screen. 3. In the Screen field, enter the field whose data the controller compares to the Value field to determine whether or not the next screen appears. 4. In the Operator field, click the down arrow on the right side of the field. Select the operator. 5. In the Value field, enter the value the controller uses to compare against the Screen field to determine whether or not the next screen appears. 6. In the Next field, enter the name of the linked screen that you want to display. 7. Choose OK to save your changes and return to the Screen Field Parameters dialog box.
11-98
Page 469
Using Screen Mapping
11
Copying a Terminal Screen 1. From the Script Builder Tools window, choose Terminal Template Tools. 2. Choose Build Screen. The Build Screen List dialog box appears. 3. In the Screen list box, select the screen that you want to copy. 4. Choose Copy. The Screen Definition dialog box appears. The new screen carries over most of the attributes of the old screen. However, you must enter a new screen name in the Name field. See the example on the next page.
5. In the Name field, enter a unique name for the terminal screen. 6. Edit the information in the fields. For help, see “Adding a Terminal Screen” earlier in this chapter.
11-99
Page 470
Model 200 Controller User’s Manual
Building Menus From Screens After you finish creating the screens, group them into logical menus that, when generated, turn into templates that are downloaded to the JANUS devices and TRAKKER Antares terminals. Note: Make sure you add all the screens (including any screens configured as Next screens) to the menu list. To build a menu 1. From the Script Builder Tools window, choose Terminal Template. 2. Choose Build Menus. The Build Menu List dialog box appears. 3. Add, edit, or delete menus. For help, see “Adding a Menu” later in this chapter. 4. Choose Close to close the dialog box and return to the Script Builder Tools window.
11-100