Using Screen Mapping

11

3. Add, edit, or delete screen mapping fields from the list box. For help, see “Adding a Screen Mapping Field Placement Entry” later in this chapter. 4. Choose Close to close the dialog box and return to the Screen Mapping Session Definition dialog box.

11-81

Page 452

Model 200 Controller User’s Manual

Adding a Screen Mapping Field Placement Entry

1. From the Screen Mapping Field List dialog box, choose Add. The Screen Mapping Field Placement dialog box appears. 2. In the Transaction field box Name field, click the down arrow on the right side of the field. A list of the transaction fields for the transaction you selected appears. Select the transaction field you want to map. 3. In the Screen box Name field, click the down arrow on the right side of the field. A list of the screens that are defined in your script file appears. Select the screen that contains the field that you want to map to the transaction field. 4. In the Screen box Field name field, click the down arrow on the right side of the field. A list of the fields that are defined for that screen in your script file appears. Select the field name that you want to map to the transaction field. 5. Choose OK to save your changes and return to the Screen Mapping Field list dialog box.

11-82

Page 453

Using Screen Mapping

11

Saving and Activating Your Run-Time Configuration When you finish configuring a section, you should save any changes you have made to disk. If you have finished configuring your controller, activate your run-time configuration. When the activate is complete, a message box appears if you need to reboot the controller. To save and activate your run-time configuration 1. From the main menu sidebar buttons, choose Save and Activate. The Activate Configuration message box appears. 2. Choose Activate. The controller saves your run-time configuration to disk and it becomes your active configuration. If you are ready to start data collection, from the main menu sidebar buttons, choose Start Data Collection.

Building Terminal Screens for Data Collection Devices Before you can run screen mapping, you need to create the terminal screens for the data collection devices. You group these terminal screens into a menu and then you generate the menu into a terminal template that you download to the terminals. The templates are displayed on a terminal screen such as on the JANUS 2020. Note: Transactions sent by TRAKKER Antares terminals and JANUS devices and running in the Intermec 2.4 GHz RF network have a maximum length of 1024 characters, including delimiters. Transactions sent by JANUS devices running in the Intermec 900 MHz RF network have a maximum length of 254 characters, including delimiters.

11-83

Page 454

Model 200 Controller User’s Manual

When you run the template on your terminal, it displays the menu that lists terminal screens into which you can enter data. The data is packaged into a transaction and sent to the controller. The controller forwards the transaction to the appropriate screen mapping session. The screen mapping session connects specific transactions to a specific host application that uses a specific script file. When the script file receives a transaction, it maps the transaction fields to the host screen fields. However, there is no direct link between terminal screen fields and host screen fields. They are linked through transaction fields. That is, a terminal screen field is linked to a host screen field if they are both mapped to the same transaction field number. Therefore, when you define a host screen field or a terminal screen field, you also need to specify transaction field mapping information. Since a linked host screen field and a terminal screen field share field attributes and transaction field mapping information, you can choose the Screen Mapping button in the Terminal and Fields dialog box to populate a terminal screen field with information from an existing host screen field. Note: If you want to get the terminal screen field information from a host screen field, you must first create your script file. When you build a new terminal screen, you may want to open two other windows on the Model 200 Controller screen. Terminal display The terminal display shows you what the screen will look like on your terminals. It shows the character positions on a terminal screen, it displays the picture field validation characters for input and output fields, and it displays any fixed fields. It does not show the default values you set for your input fields. To open the terminal display, choose View. Host window The host window can display the host node application screen. If the host screen is field-formatted, you can use the Get Field feature to obtain information about fields directly from the host screen. For help, see “Getting Terminal Field Attributes From a Host Screen” later in this chapter.

11-84

Page 455

Using Screen Mapping

11

This section explains how to build screens and menus and how to generate templates using the terminal template tools in the Script Builder Tools window. From the main menu choose Screen Mapping, and then choose Script Builder.

11-85

Page 456

Model 200 Controller User’s Manual

To build a new terminal screen 1. From the Script Builder Tools window, choose Terminal Template. 2. Choose Build Screen. The Build Screen List dialog box appears.

3. Add, edit, or delete terminal screens. For help, see “Adding a Terminal Screen” later in this chapter. Or, copy a terminal screen and then edit it. For help, see “Copying a Terminal Screen” later in this chapter. 4. Choose Close to close the dialog box and return to the Script Builder Tools window.

11-86

Page 457

Using Screen Mapping

11

Adding a Terminal Screen

Field

Description

Value

Default

Name

The unique name for the terminal screen.

1 to 16 alphanumeric characters

None

Size

The screen size of the terminal that the screen will be displayed on.

80x25, 40x13, 20x16, 20x8, 10x16, 10x8

20x16

Menu title (Optional)

The name you want to appear for the screen in the menu on the terminal.

1 to 50 alphanumeric characters

Name

11-87

Page 458

Model 200 Controller User’s Manual

Field

Description

Value

Default

Transaction

The transaction ID of the transaction that is created by this screen and that is sent to the Model 200 Controller.

1 to 20 alphanumeric characters

Name_tx

Auto send

This check box determines if the screen automatically sends the transaction when all of its fields are populated.

Check, Clear

Check

Wait for response

This check box determines if the screen waits for a transaction response before it allows further processing.

Check, Clear

Clear

To add a terminal screen 1. From the Screen List dialog box, choose Add. The Terminal Screens and Fields dialog box appears. 2. In the Name field, enter a unique name for the terminal screen. 3. In the Size field, click the down arrow on the right side of the field. A list of the available screen sizes appears. Choose the size of the terminal screen on the data collection device. 4. (Optional) In the Menu title field, enter the name that you want to appear for the screen in the menu on the terminal. If you do not enter a menu title, the screen name is used. 5. In the Transaction field, click the down arrow on the right side of the field. A list of the available transactions appears. Choose the transaction ID of the transaction that is created by this screen. If you do not enter a transaction, a transaction is created with the name “name_tx” where name is from the Screen Name field. 6. If you want another terminal screen to automatically appear when this terminal screen is populated, choose Screen. For help, see “Defining Next Screen Sequence for Terminal Screens” later in this chapter.

11-88

Page 459

Using Screen Mapping

11

7. Enable or disable the Auto send and Wait for response check boxes. If you enable the Wait for response check box, the controller waits for 20 seconds before it places the application in Hot Standby mode. The device waits for 60 seconds before it times out and attempts to resend the transaction. If you disable the Wait for response check box, the screen will not be able accept data for output fields, nor will it be able to accept system messages such as SEND_MESSAGE. 8. The Screen Field box lists all the screen fields that are already defined for this screen. You can add new fields to the screen, or you can edit and delete existing fields, or you can get a field from the host window. For help, see “Adding a Terminal Field” earlier in this chapter. Or, to get the attributes of a field from a host window, follow the instructions for “Getting Terminal Field Attributes From a Host Screen” later in this chapter. Or, to get the attributes of a field from the related host screen field attributes, choose Screen Mapping. 9. Choose View to open the Terminal Display. 10. Choose OK to save your changes and return to the Build Screen List dialog box.

Adding a Terminal Field There are several different types of fields you can add to your terminal screen. Field type - input These fields accept data. The data can be from input from a user or it can be output from a host (using the SEND_MESSAGE command). The data can be scanned or typed. You can make this field required. If this field is required and the user does not enter any information, the screen transaction cannot be sent. You can validate input fields. If the user does not enter data that falls within the validation, an error message appears on the terminal screen. Field type - output These fields display data from a host. Output fields are populated from transaction fields sent by the script file. These fields are also known as regions.

11-89

Page 460

Model 200 Controller User’s Manual

Field type - fixed These fields display the data that you enter in the Value field. Fixed fields contain static text and they do not change as the data entered in the input or output field changes. Use these fields as terminal prompts for input or use them as descriptions for output fields. Data type - date If you choose date as your data type, you cannot set the length or the picture. The controller accepts dates in these formats: MMDDYY

DDMMYY

YYMMDD

MM.DD.YY

DD.MM.YY

YY.MM.DD

MM/DD/YY

DD/MM/YY

YY/MM/DD

MM-DD-YY

DD-MM-YY

YY-MM-DD

MMDDYYYY

DDMMYYYY

YYYYMMDD

MM.DD.YYYY

DD.MM.YYYY

YYYY.MM.DD

MM/DD/YYYY

DD/MM/YYYY

YYYY/MM/DD

MM-DD-YYYY

DD-MM-YYYY

YYYY-MM-DD

Data type - time If you choose time as your data type, you cannot set the length or the picture. The controller accepts times in these formats: HHMM

HH.MM

HH:MM

HHMMSS

HH.MM.SS

HH:MM:SS

Picture This field, when combined with the length field, describes the format for an input field. For example, if the maximum length of the input field is 5, and there is one X in the Picture field, the user must enter at least one character before moving on to the next input field. If there are five Xs in the Picture field, the user must enter five characters.

11-90