Page 251

Connecting to a Coaxial/Twinaxial Network

6

To configure a twinaxial network adapter card 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Local Network Adapter. Five buttons for different network adapter card types appear. 3. Choose Twinaxial. The Twinaxial Protocol Configuration dialog box appears. 4. In the Controller address field, enter the twinaxial connection address. This value must be unique for each twinaxial device connected to the host on this line. 5. In the Max I-field size field, enter the maximum frame size used in this connection mode. 6. Choose OK to save your changes and return to the main menu.

Saving Your Run-Time Configuration When you finish configuring your network adapter card, you should save your changes. To save your run-time configuration • From the main menu sidebar buttons, choose Save Configuration.

6-7

Page 252

Model 200 Controller User’s Manual

Page 253

7 Connecting to an SDLC Network

Page 254

Model 200 Controller User’s Manual

Page 255

Connecting to an SDLC Network

7

This chapter describes how to install the controller in your SDLC network and configure the network adapter card.

Chapter Checklist Done?

‰ ‰

Task

Page

Install the controller.

7-4

Use the GUI to configure the SDLC card for the SDLC network.

7-5

If you already understand and have performed these tasks, connect the controller to another host or set up the host environment as described in these chapters: • • • • •

Chapter 5, “Connecting to an Ethernet/Token Ring Network” Chapter 6, “Connecting to a Coaxial/Twinaxial Network” Chapter 8, “Using Terminal Emulation” Chapter 9, “Using Peer-to-Peer Applications” Chapter 10, “Using Terminal Sessions”

7-3

Page 256

Model 200 Controller User’s Manual

Installing the Controller Before you can configure the Model 200 Controller, you need to install it in your network.

Equipment • An SDLC connection where you connect the controller. • An SDLC cable to connect the controller to the connection. You can use a 25 conductor IBM custom cable. Note: The SDLC card uses COM1. If you need more than one available serial port, you can purchase an Intermec serial I/O board. To install the controller 1. Locate the slot that contains the SDLC card on the rear panel of your controller. The SDLC card is the card that is furthest right when you are looking at the rear panel. The connector on the card looks like the figure on the left. 2. Insert one end of the cable in the port on the card and the other end in the connection.

0200-020

7-4

Page 257

Connecting to an SDLC Network

7

Configuring the Network Adapter Card After you install the Model 200 Controller, you need to turn it on and configure its network adapter cards. Use the worksheets in Appendix E. Before you configure the network adapter card, obtain the local station address from your network administrator. You may also need to know the line type, line mode, modem speed, NRZI, and maximum I-field size.

Field

Description

Value

Default

Local station

The address (in hex) that identifies the controller station.

01 to FE

01

To configure an SDLC network adapter card 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Local Network Adapter. Five buttons for different network adapter card types appear. 3. Choose SDLC. The SDLC Adapter Configuration dialog box appears. 4. In the Local station field, enter the address that identifies the controller’s station. 5. Configure any advanced parameters for SDLC. For help, see, “Configuring Advanced SDLC Parameters” in the next section. 6. Choose OK to save your changes and return to the main menu.

7-5

Page 258

Model 200 Controller User’s Manual

Configuring Advanced SDLC Parameters

Field

Description

Value

Default

Line type

The type of telecommunications link that the controller is using. Switched lines are the dialed type. Non-switched lines are the leased type.

Switched, Non-switched

Switched

Line mode

The type of cable you are using to connect the controller to your host.

Full duplex, Half duplex

Half duplex

NRZI

Non-return-to-zero inverted. The data encoding for modems that are sensitive to certain bit patterns.

On, Off

On

Link station role

This field sets the role of the controller to be the primary workstation or the secondary workstation to the host.

Primary, Negotiable, Secondary

Secondary

7-6

Page 259

Connecting to an SDLC Network

Field

Description

Value

Default

Max I-field size

The maximum frame size that is used in this connection mode.

265 to 4105

1033

Send XID response immediately

This check box determines if the controller sends the XID response without waiting for the host to send the XID request.

Check, Clear

Clear

7

To configure the advanced SDLC parameters 1. From the SDLC Protocol Configuration dialog box, choose Advanced. The Advanced SDLC Adapter Protocol Configuration dialog box appears. 2. Choose the Line type to be Switched or Non-switched. 3. Choose the Line mode to be Full duplex or Half duplex. 4. Choose the NRZI to be On or Off. 5. In the Link station role field, click the down arrow on the right side of the field. A list of roles appears. Select the controller to be the primary or secondary workstation. Note: If you are configuring 3270 terminal emulation, the default for this field is Secondary. When you are communicating with a mainframe, this field is typically Secondary. Or, choose Negotiable if you want the controller and host to negotiate their roles when they connect. 6. In the Max I-field size, enter the maximum frame size that is used in this connection mode. 7. Decide if you want the controller to send its XID response before the host requests it. Enabling this check box sends the XID response immediately. This XID is also the Node ID. 8. Choose OK to save your changes and return to the SDLC Protocol Configuration dialog box.

7-7

Page 260

Model 200 Controller User’s Manual

Saving Your Run-Time Configuration When you finish configuring your network adapter card, you should save your changes. To save your run-time configuration • From the main menu sidebar buttons, choose Save Configuration.

7-8