Page 241
Connecting to an Ethernet/Token Ring Network
5
Advanced Protocol Configuration Dialog Box for the Token Ring Card
4. In the Protocols field, click the down arrow on the right side of the field. Select IEEE 802.2. 5. (Token ring only) Choose the ring speed of your token ring network. The default ring speed is 16 Mbps. 6. Choose Advanced. The IEEE 802.2 Adapter Protocol Configuration dialog box appears.
5-17
Page 242
Model 200 Controller User’s Manual
Field
Description
Value
Default
IEEE 802.2 card
The card that you are configuring.
Ethernet 1 Ethernet 2 Token Ring 1
Ethernet 1 Token Ring 1
Network adapter address (Optional)
The locally administered MAC address in IEEE format (hex) that identifies the card.
020000000000 through FEFFFFFFFFFF
The MAC address that is on the card.
Ethernet driver support
The Ethernet frame type you are using.
IEEE 802.3 or Ethernet DIX (Ethernet II)
IEEE 802.3
Maximum link stations
The maximum number of link stations that can exist for all SAPs concurrently.
Based on how the controller is configured.
8
To configure the IEEE 802.2 protocol 1. In the IEEE 802.2 Adapter Protocol Configuration dialog box, click the down arrow on the right side of the IEEE 802.2 card field. Select the card you want to configure. Note: If you have two or more 10 Mbps Ethernet cards, Ethernet 1 is the Ethernet card that is in the slot the furthest left if you are facing the controller front panel. If you have a 100 Mbps Ethernet card, it is Ethernet 1. 2. (Optional) In the Network adapter address field, enter a locally administered MAC address. This address overrides the one on the card. To see the default address, view the run-time configuration. 3. In the Ethernet driver support field, click the down arrow on the right side of the field. Select IEEE 802.3 or Ethernet DIX. 4. In the Maximum link stations field, enter the maximum number of link stations that can exist for all SAPs concurrently. Or, choose Auto Calc if you want the controller to determine the optimal values for this field based on how the controller is configured. 5. Choose OK to save your changes and return to the Advanced Protocol Configuration dialog box.
5-18
Page 243
Connecting to an Ethernet/Token Ring Network
5
Saving Your Run-Time Configuration When you finish configuring your network adapter card, you should save your changes. To save your run-time configuration • From the main menu sidebar buttons, choose Save Configuration.
5-19
Page 244
Model 200 Controller User’s Manual
Page 245
6 Connecting to a Coaxial/Twinaxial Network
Page 246
Model 200 Controller User’s Manual
Page 247
Connecting to a Coaxial/Twinaxial Network
6
This chapter describes how to connect the controller to your host using a coaxial or twinaxial connection and it also explains how to configure the network adapter card.
Chapter Checklist Done?
‰ ‰
Task
Page
Install the controller.
6-4
Use the GUI to configure the coaxial card for the coaxial network.
6-5
Or, Use the GUI to configure the twinaxial card for the twinaxial network.
6-6
If you already understand and have performed these tasks, connect the controller to another host or set up the host environment as described in these chapters: • • • • •
Chapter 5, “Connecting to an Ethernet/Token Ring Network” Chapter 7, “Connecting to a SDLC Network” Chapter 8, “Using Terminal Emulation” Chapter 9, “Using Peer-to-Peer Applications” Chapter 10, “Using Terminal Sessions”
6-3
Page 248
Model 200 Controller User’s Manual
Installing the Controller Before you can configure the Model 200 Controller, you need to install it in your network.
Equipment • A coaxial or twinaxial connection where you can connect the controller. • A cable to connect the controller to the connection. You can use a RG-58 coaxial cable, or for a twinaxial connection you can use 15 conductor IBM custom cable. To install the controller 1. Locate the slot that contains the coaxial or twinaxial card on the rear panel of your controller. The twinaxial or coaxial card is the card that is furthest right when you are looking at the rear panel. Refer to the figure on the left. The card end on the left shows a coaxial connector and the card end on the right shows a twinaxial connector. 2. Insert one end of the cable in the port and the other end in the coaxial or twinaxial connection.
0200-021
0200-022
6-4
Page 249
Connecting to a Coaxial/Twinaxial Network
6
Configuring the Coaxial Adapter Card If you have a coaxial network adapter card in the controller, you do not need to enter any configuration parameters. You can choose the type of communication you are using, Local Network Adapter, and then Coaxial. This message box appears:
Choose OK to close the dialog box.
6-5
Page 250
Model 200 Controller User’s Manual
Configuring the Twinaxial Adapter Card After you install the Model 200 Controller, you need to turn it on and configure its network adapter cards. Use the worksheets in Appendix E. Before you configure the network adapter card, obtain the controller address and the maximum I-field size from your network administrator.
Field
Description
Value
Default
Controller address
The address of the host twinaxial connection.
0 to 6
0
Max I-field size
The maximum frame size that is used in this connection mode.
265 to 4105
1033
6-6