Now that you have configured the Model 200 Controller to communicate with your LAN and you have configured it to communicate with your Intermec RF network, you are ready to tie the entire data collection network together using an application, such as terminal emulation. This chapter describes how to configure your controller for using VT, ANSI, 5250, or 3270 terminal emulation (TE) with your JANUS devices and TRAKKER Antares terminals.
Chapter Checklist Done?
‰ ‰
Task
Page
Understand how terminal emulation (TE) runs on the host, controller, and data collection devices.
8-5
For VT, ANSI, TN5250, or TN3270 TE, identify all the TCP/IP hosts on the network. If necessary, link and unlink terminal addresses to TCP/IP hosts.
8-7
Or,
‰ ‰ ‰ ‰
For 5250 TE, identify all the IBM SNA hosts on the network. If necessary, link and unlink terminal addresses to IBM SNA hosts.
8-12
For 3270 TE, identify all the IBM SNA hosts on the network. If necessary, define the NAU pool and link and unlink terminal addresses to IBM SNA hosts.
8-22
Save and activate the configuration.
8-29
Configure your JANUS devices for TE.
8-30
To run VT and ANSI TE on your JANUS devices, download the TE files.
8-31
Configure your TRAKKER Antares terminals for TE.
8-40
8-3
Page 264
Model 200 Controller User’s Manual
Done?
‰
Task
Page
Set security for accessing the TE Configuration menu.
8-46
Note: If your JANUS 2.4 GHz RF devices are running TCP/IP, you do not need a Model 200 Controller to run VT or ANSI TE, TN5250, or TN3270. If your JANUS 2.4 GHz RF devices are running UDP Plus, you need to use a Model 200 Controller. Note: You can also use the controller as an IP bridge to send transactions to a TCP/IP host on your token ring network. When you understand these sections and perform these tasks, you can start using the controller.
8-4
Page 265
Using Terminal Emulation
8
About Terminal Emulation Terminal emulation (TE) lets data collection devices communicate through the Model 200 Controller as if they were directly connected to the host. The controller sends data to the device in a screen format that emulates the host session. Vehicle-mount terminals automatically see the entire screen. Other terminals have viewporting abilities; that is, you can use commands to move the smaller device screen around to see a much larger terminal screen. TCP/IP Host
Ethernet Token ring
IBM SNA Host (3270) Ethernet Token ring SDLC
Model 200 Controller
IBM SNA Host (5250) Ethernet Token ring Twinaxial SDLC
Data Collection Network
0200-026
The next table provides a summary of what TE applications you can run on which networks.
8-5
Page 266
Model 200 Controller User’s Manual
Host Connectivity Table Ethernet
Token Ring
Coaxial
Twinaxial
SDLC
VT and ANSI
Yes
Yes
No
No
No
5250
Yes
Yes
No
Yes
Yes
3270
Yes
Yes
No
No
Yes
TN5250
Yes
Yes
No
No
No
TN3270
Yes
Yes
No
No
No
Using the Model 200 Controller, you can run VT/ANSI TE on JANUS UDP Plus devices and TRAKKER Antares terminals. The UNIX or other TCP/IP host must support Telnet. You can also run TN5250 or TN3270 on TRAKKER Antares terminals. Your IBM host must support Telnet. When you send data from the device, the controller routes it to the Telnet session on the host. Using the controller, you can also run IBM SNA 5250 TE or IBM SNA 3270 TE on JANUS UDP Plus devices and TRAKKER Antares terminals to an IBM AS/400 or other IBM SNA host. Your controller is licensed to communicate with a fixed number of devices (1-8, 1-24, 1-64, 1-128). When a device first sends a message through the controller, the controller logs its logical name. When the controller logs the maximum number of logical names that your device license allows, it will not accept messages from any new addresses. If you need to purchase an upgrade to your terminal license, contact your local Intermec representative.
JANUS TE Application For JANUS devices that run VT or ANSI TE, the Model 200 Controller provides the JANUS TE application. For JANUS 900 MHz RF devices that run 5250 or 3270 TE, your devices are preloaded with a JANUS TE application. However, this application is also loaded on the controller, if you need to download it to your device. Your device must be running firmware v3.1 or later. For help, see “Downloading the JANUS TE Application” later in this chapter.
8-6
Page 267
Using Terminal Emulation
8
Note: If you are replacing a 9185 controller with a Model 200 Controller, you must download the new JANUS TE application to all your JANUS devices.
TRAKKER Antares TE Application TRAKKER Antares terminals can run VT, ANSI, 5250, or 3270 TE. Your devices are preloaded with the TRAKKER Antares TE application. However, this application is also loaded on the controller, if you need to download it to your device. For help, see “Downloading the TRAKKER Antares TE Application” later in this chapter.
Setting Up Telnet Terminal Emulation When you set up your data collection network to run Telnet TE, you need to configure the Model 200 Controller and the data collection devices. Telnet TE includes VT100, VT220, VT320, ANSI, TN5250, and TN3270. Note: For VT, ANSI, TN5250, and TN3270 TE, your network administrator does not need to configure anything on the host.
Configuring the Controller To run Telnet TE between JANUS devices and TRAKKER Antares terminals and the host, you need to identify all the TCP/IP hosts and use DNS or manually enter their IP addresses. Then, you can explicitly link or unlink terminal names to hosts. If an explicit link is set up between a terminal and a host, it means that the terminal can only start TE sessions with that host. If no explicit link is set up, the terminal can start a TE session with any host in the Host Name list. The terminal will start a TE session with the host that is configured on it. Before you proceed, make sure you have already performed these tasks: • Installed the Model 200 Controller. • Installed and configured the connection points and downline devices. • Configured the network adapter cards.
8-7
Page 268
Model 200 Controller User’s Manual
Field
Description
Value
Default
Host Name
This list box contains the logical names of the TCP/IP hosts that you have defined.
Predefined
None
Host Name Linked Terminals
The terminal names that are linked to a specific host.
None
None
Available Terminals
The list of all the terminal names that are available to add to the Host Name Linked Terminals list box.
Predefined
All configured terminals
8-8
Page 269
Using Terminal Emulation
8
To set up Telnet terminal emulation 1. From the main menu, choose Terminal Emulation. 2. Choose Telnet Terminal Emulation. The Telnet Terminal Emulation Configuration dialog box appears. 3. Make sure that you have added all your TCP/IP hosts. The Host Name list box contains all the existing host names. For help, see “Adding a TCP/IP Host” in the next section. Note: You cannot delete a host if it is linked to a device or a terminal session. 4. (Optional) Create any explicit links between terminals and hosts. a. In the Host Name list box, select the host that you want to link to a terminal. b. In the Available Terminals list box, select the logical name of the terminal that you want to link to the host. c. Choose Link. The host name and the terminal appear in the Host Name - Linked Terminals list box. 5. (Optional) Unlink any explicit links between terminals and hosts. a. In the Host Name - Linked Terminals list box, select the host and the logical name of the terminal you want to unlink. b. Choose Unlink. The host name and the terminal are removed from the Host Name - Linked Terminals list box. 6. Choose Close to close the dialog box and return to the main menu.
8-9
Page 270
Model 200 Controller User’s Manual
Adding a TCP/IP Host To communicate with TCP/IP hosts, the Model 200 Controller must know their IP addresses. You can either use DNS to resolve these IP addresses or you can enter them in manually.
Field
Description
Value
Default
Host name
The name that logically identifies the TCP/IP host to the network.
1 to 256 alphanumeric characters
None
Use DNS
This check box determines if you use a DNS server to resolve the IP address of this host.
Check, Clear
Clear
IP address
The address that identifies the TCP/IP host to the network.
xxx.xxx.xxx.xxx where xxx is a value between 0 and 255.
None
8-10