For the Intermec 0200

Page 211

Connecting to the 9180 and the Intermec CrossBar Network

4

Field

Description

Value

Default

Stop bits

The number of bits to use for setting communications protocol.

1, 2

1

Hot Standby Timeout

The number of seconds the Model 200 Controller waits for a response from the 9161 controller before it places the 9161 controller in Hot Standby mode.

1 to 9999

40

Integrity Mode

This mode determines the amount of transaction verification the Model 200 Controller performs.

Faster, Safer

Faster

Transactions held in volatile memory

The number of transactions the controller keeps in volatile RAM before it begins to write them to a Hot Standby file.

None, Unlimited, Maximum

Maximum 50

Multi-Drop Enabled

The Multi-Drop lines (up to four) that the 9161-02 controller supports. The 9161-01 controller does not support this feature.

m, n, o, p p

To edit the parameters for a 9161 controller 1. In the Connection Point List dialog box, select the 9161 controller and then choose Add. The Setup for Controller dialog box appears. 2. In the Serial port field, click the down arrow on the right side of the field. A list of available COM ports appears. Select the COM port on the controller that connects to the 9161 controller. 3. In the Baud rate field, click the down arrow on the right side of the field. A list of baud rates appears. Select the baud rate you want to use to communicate with the 9161 controller. 4. Enable or disable the LRC check box. The LRC provides additional data integrity. 5. Choose the parity, data bits, and stop bits. These parameters must match the parameters configured on the 9161 controller.

4-11

Page 212

Model 200 Controller User’s Manual

6. In the Hot Standby Timeout box, enter the number of seconds you want the Model 200 Controller to wait for a response from the 9161 controller before it places the 9161 controller in Hot Standby mode. 7. In the Integrity Mode box, choose the mode that determines the amount of transaction verification the Model 200 Controller performs. 8. In the Transactions Routed to This Controller box, choose the number of transactions you want the controller to keep in RAM before it writes them to a Hot Standby file. • Choose None if you want the transaction always written to the file. • Choose Unlimited if you don’t want the transaction written to the file unless the time you set for the Hot Standby timeout expires. • Choose Maximum and enter a maximum number of transactions. When the controller has this number of transactions in RAM, it writes them to a file. 9. Choose Time Parameters to set the time parameters for the 9161 controller. For help, see “Setting the Time Parameters” later in this section. Note: Intermec recommends that you enable the time append feature when you set the time parameters. If you do not enable this feature, you may see a “protocol error occurred” message in the error log. 10. (9161-02 only) In the Multi-Drop enabled box, choose the Multi-Drop lines that the 9161-02 controller supports (up to four). 11. Choose OK to save your changes and return to the Connection Point List dialog box.

4-12

Page 213

Connecting to the 9180 and the Intermec CrossBar Network

4

Adding a 9180 Controller

Field

Description

Value

Default

Serial port

The communications port to which the 9180 controller is connected.

COM1, COM2

COM1

Baud rate

The baud rate at which the serial port communicates.

Predefined

9600

LRC enabled

This check box determines if the longitudinal redundancy check character is appended to data transmitted by a device.

Check, Clear

Clear

Parity

The type of self-checking you want to use when sending data.

Even, Odd, None

Even

Data bits

The number of bits to use for setting communications protocol.

7, 8

7

4-13

Page 214

Model 200 Controller User’s Manual

Field

Description

Value

Default

Stop bits

The number of bits to use for setting communications protocol.

1, 2

1

Hot Standby Timeout

The number of seconds the Model 200 Controller waits for a response from the 9180 controller before it places the 9180 controller in Hot Standby mode.

1 to 9999

40

Integrity Mode

This mode determines the amount of transaction verification the Model 200 Controller performs.

Faster, Safer

Faster

Transactions held in volatile memory

The number of transactions the controller keeps in volatile RAM before it begins to write them to a Hot Standby file.

None, Unlimited, Maximum

Maximum 50

To edit the parameters for a 9180 controller 1. In the Connection Point List dialog box, select the 9180 controller and then choose Add. The Setup for Controller dialog box appears. 2. In the Serial port field, click the down arrow on the right side of the field. A list of available COM ports appears. Select the COM port on the controller that connects to the 9180 controller. 3. In the Baud rate field, click the down arrow on the right side of the field. A list of baud rates appears. Select the baud rate you want to use to communicate with the 9180 controller. 4. Enable or disable the LRC check box. The LRC provides additional data integrity. 5. Choose the parity, data bits, and stop bits. These parameters must match the parameters configured for the 9180 controller. 6. In the Hot Standby Timeout box, enter the number of seconds you want the Model 200 Controller to wait for a response from the 9180 controller before it places the 9180 controller in Hot Standby mode. 7. In the Integrity Mode box, choose the mode that determines the amount of transaction verification the Model 200 Controller performs.

4-14

Page 215

Connecting to the 9180 and the Intermec CrossBar Network

4

8. In the Transactions Routed to This Controller box, choose the number of transactions you want the controller to keep in RAM before it writes them to a Hot Standby file. • Choose None if you want the transaction always written to the file. • Choose Unlimited if you don’t want the transaction written to the file unless the time you set for the Hot Standby timeout expires. • Choose Maximum and enter a maximum number of transactions. When the controller has this number of transactions in RAM, it writes them to a file. 9. Choose Time Parameters to set the time parameters for the 9180 controller. For help, see “Setting the Time Parameters” later in this section. 10. Choose OK to save your changes and return to the Connection Point List dialog box.

Setting the Time Parameters Use this dialog box to configure the time broadcast and time append parameters. These time parameters synchronize the external Intermec controllers with their devices. In the System Parameters dialog box, you can set a time synchronization parameter that synchronizes the time on the Model 200 Controller with its external Intermec controllers. If the external Intermec controller does not support one of the parameters, it is grayed out. Broadcast Parameters These optional parameters broadcast a time, with a short string, at certain intervals from the external Intermec controller to all data collection devices connected to it. These parameters synchronize the data collection devices with the controller. Append Parameters These optional parameters configure the external Intermec controllers to stamp the time at certain intervals to incoming data. The timestamp is in the format:

HH:MM:SS

4-15

Page 216

Model 200 Controller User’s Manual

If you want all messages to have a timestamp with the hour and minute, enable this feature and set the interval to 0. Depending on your controller, you can also append the seconds. If no data is available within the interval, the controller waits until it receives data and then appends the time before sending it to the host. This feature will not operate when running terminal emulation or using the direct TCP/IP socket interface. Note: Do not enable time append on both the external Intermec controller and the data collection device itself. If it is enabled on both, two timestamps are appended to incoming data.

4-16

Page 217

Connecting to the 9180 and the Intermec CrossBar Network

Field

Description

Value

Default

Broadcast enabled

This check box determines if the external Intermec controller broadcasts its time to its devices.

Check, Clear

Clear

Include Seconds (9180 only)

This check box adds seconds to the time.

Check, Clear

Clear

Include Date (9154/9180 only)

This check box adds the date to the time.

Check, Clear

Clear

Interval

This field specifies how often the controller sends the time broadcasts.

0 to 99 minutes

1

Preamble (9154/9180 only)

This field lets you add a short message to the beginning of the time.

1 to 5 alphanumeric characters

None

Postamble (9154/9180 only)

This field lets you add a short message to the end of the time.

1 to 5 alphanumeric characters

None

Time format (9154/9180 only)

These option buttons choose the time broadcast format.

12 hour, 24 hour

12 hour

Append enabled

This check box determines if a timestamp is added to messages from devices.

Check, Clear

Clear

Include Seconds (9180 only)

This check box adds a 2-digit seconds to the time.

Check, Clear

Clear

Record day rollover (9154/9180 only)

This check box adds a timestamp in the buffer of the host at midnight.

Check, Clear

Clear

Interval

This field specifies how often in minutes the controller appends the timestamp.

0 to 99

1

4

4-17

Page 218

Model 200 Controller User’s Manual

To configure the time parameters 1. From the Setup for Controller dialog box, in the Time Parameters box, choose Configure. The Configure Time Parameters dialog box appears. 2. In the Broadcast Parameters box, enable or disable the time broadcast. A check in the Broadcast enabled check box means that time broadcast is enabled. If you do not enable time broadcast, skip to Step 8. 3. Enable or disable including seconds in the time. A check in the Include Seconds check box means that seconds are added. 4. Enable or disable including the date in the time. A check in the Include Date check box means that the date is added. 5. Choose 12 Hour or 24 Hour time format. 6. In the Interval field, enter how often you want the controller to do a time broadcast. If you set this field to 0, no time broadcast is made. Note: Using 0 to disable time broadcast is not supported on the 9180 controller. 7. In the Preamble and Postamble fields, enter a short message you want to add before or after the time. 8. In the Append Parameters box, enable or disable the time append. A check in the Append enabled check box means a timestamp is added to messages at a certain interval. If you do not enable time append, skip to Step 12. Note: If you are configuring a 9161 controller, you need to set the internal DIP switches to enable the time append feature. You can use this dialog box to set the interval of the time append. 9. Enable or disable Include Seconds. A check in the check box means that seconds are included in the time stamp. 10. Enable or disable placing a timestamp in the buffer for the host at midnight. A check in the Record day rollover check box adds the time stamp.

4-18

Page 219

Connecting to the 9180 and the Intermec CrossBar Network

4

11. In the Interval field, enter how often you want the controller to append a timestamp on messages from devices. If you set this field to 0, every message from a device will have a timestamp. 12. Choose OK to save your changes and return to the Setup for Controller dialog box.

Identifying the CrossBar Devices The Model 200 Controller needs to know the addresses of all the devices that use it to communicate with the host. This section explains how to configure the controller for the CrossBar devices. The device list is automatically populated with device addresses as you configure the external Intermec controllers. The first eight addresses are enabled and are configured as J2020s. You need to change the device type for these addresses and enable the addresses of the other devices that you want to communicate with the host. You can also edit the individual parameters for each address. Note: Do not enable devices that you are not using. If you try to send data to a nonexistent but enabled device, your system performance will degrade. Your controller has a terminal license that allows it to communicate with a limited number of device addresses (1-8, 1-24, 1-64, 1-128). The controller does not keep track of the number of devices you enable. You can enable all 128 devices. As each device sends messages to the controller, the controller logs its address. When the controller logs the maximum number of addresses that your terminal license allows, it will not accept messages from any new addresses. If you need to upgrade your terminal license, contact your local Intermec representative. To identify CrossBar devices 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear.

4-19

Page 220

Model 200 Controller User’s Manual

3. Choose Downline Devices. The Device List dialog box appears. 4. In the Connection field, click the down arrow on the right side of the field. A list of the controllers that are configured appears.

5. Select the controller whose devices you want to configure. The Device List displays the status, physical address, and logical name of all 128 devices. 6. To enable all 128 devices, choose Enable All. Or, to enable specific devices, select the device you want to enable and make sure there is a check in the Enabled check box. 7. To disable all 128 devices, choose Disable All. Or, to disable specific devices, select the device you want to disable and make sure there is no check in the Enabled check box.

4-20