The text of a manual · part 23 of 70
Model 200 Controller System Manual, pages 221 to 230
Pages 221 to 230 of 695
The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 0200
Page 221
Connecting to the 9180 and the Intermec CrossBar Network
4
8. Select a device whose individual parameters you want to edit and choose Edit Device. For help, see “Editing a CrossBar Device” in the next section. 9. Choose OK to save your changes and return to the main menu.
Editing a CrossBar Device
Field
Description
Value
Default
Logical name
The logical name of this device.
1 to 16 alphanumeric characters
Intermec standard
Able to receive data
This check box determines if this device can receive data from the network.
Check, Clear
If the device has a display, it is checked, else it is cleared.
4-21
Page 222
Model 200 Controller User’s Manual
Field
Description
Value
Default
Device type
This list box contains all the current Intermec devices supported by the Model 200 Controller.
Predefined
J2020
Physical address
This read-only field displays the physical address of the device.
Predefined
Predefined
Auto-insert from device
This field adds a transaction ID to end devices that cannot put a transaction ID in the transactions they send.
Predefined list
None
To be routed to device
This field contains the transaction ID that will always be routed to this device.
Predefined list
None
Interactive response (Optional)
The message that is sent to the source of the transaction if the transaction for this device is delivered successfully in Interactive mode.
1 to 39 characters
None
Hot standby (Optional)
The message that is sent to the source of the transaction if the transaction for this device is not delivered.
1 to 40 characters
None
To edit a CrossBar device Note: If you are using VT or ANSI terminal emulation, do not configure transaction IDs or delivery responses. 1. From the Device List dialog box, select a device whose individual parameters you want to edit and choose Edit Device. The Device Parameters dialog box appears. 2. In the Logical name field, enter the logical name for the device that the network uses to identify it. 3. Enable or disable the check box that determines if the device can receive data from the system.
4-22
Page 223
Connecting to the 9180 and the Intermec CrossBar Network
4
4. In the Device type field, click the down arrow on the right side of the field. A list of all the supported Intermec devices appears. Select the type of device you are configuring. 5. In the Auto-insert from device field, click the down arrow on the right side of the field. A list of all the transaction IDs appears. Select the transaction ID you want to use if the device cannot put a transaction ID in the transactions it sends. Note: All transactions from this terminal will be routed using this transaction ID. 6. In the To be routed to device field, click the down arrow on the right side of the field. A list of all transaction IDs appears. Select the transaction ID you want to always route to this device. 7. (Optional) In the Delivery Responses box, enter the messages you want to send to the transaction source. • In the Interactive response field, enter the message you want sent back to the source of the transaction if the delivery of the transaction for this device is successful in Interactive mode. • In the Hot standby field, enter the message you want sent back to the source of the transaction if the delivery of the transaction for this device is not immediately successful and is written to a Hot Standby file. 8. Choose OK to save your changes and return to the Device List dialog box.
Saving Your Run-Time Configuration When you finish configuring your downline network, you should save your changes. To save your run-time configuration • From the main menu sidebar buttons, choose Save Configuration.
4-23
Page 224
Model 200 Controller User’s Manual
Page 225
5 Connecting to an Ethernet/ Token Ring Network
Page 226
Model 200 Controller User’s Manual
Page 227
Connecting to an Ethernet/Token Ring Network
5
This chapter describes how to install the controller in your Ethernet or token ring network and how to configure the network adapter card.
Chapter Checklist Done?
‰ ‰ ‰
Task
Page
Install the controller in the Ethernet network.
5-4
Install the controller in the token ring network.
5-5
Use the GUI to configure each Ethernet and token ring card for TCP/IP.
5-6
Or,
‰ ‰
Use the GUI to configure each Ethernet and token ring card for IEEE 802.2.
5-16
Save your run-time configuration.
5-19
If you already understand and have performed these tasks, either connect the controller to another host or set up the host environment as described in these chapters: • • • • •
Chapter 6, “Connecting to a Coaxial/Twinaxial Network” Chapter 7, “Connecting to an SDLC Network” Chapter 8, “Using Terminal Emulation” Chapter 9, “Using Peer-to-Peer Applications” Chapter 10, “Using Terminal Sessions”
5-3
Page 228
Model 200 Controller User’s Manual
Installing the Controller in an Ethernet Network Your Model 200 Controller contains a 10/100 Mbps Ethernet card. The card automatically switches between 10 Mbps and 100 Mbps. The default configuration for the Ethernet card is 10BaseT or 100BaseTX. Before you can configure the Model 200 Controller, you need to install it in your network.
Equipment • An Ethernet connection where you can connect the controller. • A cable to connect the controller to the connection. For a 10BaseT or 100BaseTX connection, you use RJ-45. To install the controller 1. Locate the slot that contains the Ethernet card(s) on the rear panel of your controller. The figure on the left shows the connector for the Ethernet card. 2. Insert one end of the cable into the appropriate Ethernet port on the card and the other end into the Ethernet connection.
0200-099
5-4
Page 229
Connecting to an Ethernet/Token Ring Network
5
Installing the Controller in a Token Ring Network Before you can configure the Model 200 Controller, you need to install it in your network.
Equipment • A token ring connection where you can connect the controller. • A cable to connect the controller to the connection. Your token ring card comes with an RJ-45 to STP cable. Note: The default ring speed for the token ring card is 16 Mbps. Contact your local Intermec representative if you need to set the ring speed to 4 Mbps. To install the controller 1. Locate the slot that contains the token ring card on the rear panel of your controller. The token ring card is the card that is furthest right when you are looking at the rear panel. The connector on the card looks like the figure on the left. 2. Insert one end of the cable in the token ring port on the card and the other end in the token ring connection.
0200-019
5-5
Page 230
Model 200 Controller User’s Manual
Configuring the Network Adapter Card for TCP/IP After you install the Model 200 Controller, you need to turn it on and configure its network adapter cards. Ethernet and token ring cards support both TCP/IP and IEEE 802.2 protocols. Use the worksheets in Appendix E. To configure the card for TCP/IP, either use a Dynamic Host Configuration Protocol (DHCP) server to provide the controller TCP/IP information or enter the TCP/IP configuration manually. If you do not enter an IP address or subnet mask and you do not check the Use DHCP check box, TCP/IP communications are disabled. Use a DHCP server to provide TCP/IP information You can configure the controller to be a DHCP client in a network that uses a DHCP server. The server can provide the controller with an IP address assignment and other basic IP configuration characteristics, such as the subnet mask, the router IP address, and the DNS server address. Note: The controller supports only one network adapter card that is using DHCP. For each TRAKKER Antares terminal, you must scan the Enable DHCP bar code if you want it to be able to look for the controller that is a DHCP client. Enable DHCP
! *$+NI0*
Disable DHCP
! (+& *$+NI1*
Note: To use DHCP across routers in your network, the routers must have the DHCP relay agent configured and enabled. For help, see your router user’s manual. Enter the TCP/IP information manually From your network administrator, obtain a valid IP v4 address for each Ethernet and token ring card. You may also need to know the controller’s local host name and the subnet mask. If you have two or more cards communicating using TCP/IP, each card must be on a different subnet. If you are going to set up routing tables for the TCP/IP configuration, you also need the IP addresses of the route destinations and of the routers.
5-6