Page 201

4 Connecting to the 9180 and the Intermec CrossBar Network

Page 202

Model 200 Controller User’s Manual

Page 203

Connecting to the 9180 and the Intermec CrossBar Network

4

This chapter describes how to configure the controller to communicate with the 9180 Network Controller, other controllers in Intermec’s CrossBar network, and the CrossBar devices.

Chapter Checklist Done?

‰ ‰ ‰ ‰ ‰ ‰

Task

Page

Install all your external Intermec controllers.

None

Identify all the external controllers on the Model 200 Controller.

4-4

Configure each external controller connected to the Model 200 Controller.

4-7

Set the time parameters for each external controller.

4-15

Identify all the CrossBar devices connected to external controllers.

4-19

Edit the CrossBar devices.

4-21

Note: In order for the 9181 Base Radio Units (BRUs) to communicate with a 9180 Network Controller that is connected to the Model 200 Controller, you need to configure these BRUs using the 9180 configuration menu. Refer to your 9180 user’s manual. If you already understand and have performed these tasks, connect the controller to your Intermec RF network or host environment as described in these chapters: • • • •

Chapter 3, “Connecting to the Intermec RF Network” Chapter 5, “Connecting to an Ethernet/Token Ring Network” Chapter 6, “Connecting to a Coaxial/Twinaxial Network” Chapter 7, “Connecting to an SDLC Network”

4-3

Page 204

Model 200 Controller User’s Manual

Configuring an External Intermec Controller An external Intermec controller is a 9180 Network Controller, 9161 Port Concentrator, or a 9154 Multi-Drop Line Controller that is connected to the Model 200 Controller through a serial port. The following illustration is an example of a controller connected to a 9180 and a CrossBar network.

Example: The Model 200 Controller Connected to a 9180 and CrossBar Network Host

Model 200 Controller

RS-232

RS-232

9154

9180

JR2020 JR2020

9445 9560

9181

9181

0200-030

4-4

Page 205

Connecting to the 9180 and the Intermec CrossBar Network

4

To configure the controller to work with an external Intermec controller 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Connection Points. The Connection Point List dialog box appears. 4. Add, edit, or delete external Intermec controllers. For help, see “Adding a Controller” in the next section. 5. Choose Close to close the dialog box and return to the main menu.

Adding a Controller 1. In the Connection Point List dialog box, choose Add. The Add a Downline Connection Point dialog box appears. 2. In the Downline Connections list box, select the controller that you want to add. 3. Choose Add. The setup dialog box for the controller appears. 4. Configure the controller. For help, see “About the Controller Parameters” in the next section and then see the appropriate section for your controller.

4-5

Page 206

Model 200 Controller User’s Manual

5. Set any time parameters for the controller. For help, see “Setting the Time Parameters” later in this chapter. 6. Choose OK to save your changes and return to the Connection Point List dialog box. Choose Close to return to the main menu.

About the Controller Parameters When you configure an external Intermec controller, you may need to configure the communication parameters, set the hot standby timeout, define the integrity mode, set time parameters, and enable the correct MultiDrop port. Use the worksheets in Appendix E. Communication Parameters These required parameters define how the serial port on the Model 200 Controller communicates with the controllers that are connected to it. Make sure that any communication parameters that you define on the Model 200 Controller are the same as the parameters set on the external Intermec controller. Hot Standby Timeout This required parameter sets the amount of time in seconds the Model 200 Controller waits after delivering a transaction to a device to receive an acknowledgment for the transaction. If it does not receive an acknowledgment, the controller writes all transactions for the device to a Hot Standby file. The device receives its transactions from the Hot Standby file either when it sends an acknowledgment to the most recently delivered transaction or when it sends a system transaction. Before the device becomes interactive again, it receives all the transactions, from oldest to newest, that are in its Hot Standby file. Integrity Mode This mode determines the amount of transaction verification that the Model 200 Controller performs. In Faster mode, the Model 200 Controller acknowledges the transaction as soon as it receives the transaction from the external Intermec controller. In Safer mode, the Model 200 Controller acknowledges the transaction only after it is stored in a Hot Standby file. In Safer mode, transaction throughput is slower because the controller cannot accept another transaction from the device until it verifies the previous one. Multi-Drop Enabled This required parameter defines which Multi-Drop line the external Intermec controller uses.

4-6

Page 207

Connecting to the 9180 and the Intermec CrossBar Network

4

Adding a 9154 Controller

Field

Description

Value

Default

Serial port

The communications port to which the 9154 controller is connected.

COM1, COM2

COM1

Baud rate

The baud rate at which the serial port communicates.

Predefined

9600

LRC enabled

This check box determines if the longitudinal redundancy check character is appended to data transmitted by a device.

Check, Clear

Clear

Parity

The type of self-checking you want to use when sending data.

Even, Odd, None

Even

Data bits

The number of bits to use for setting communications protocol.

7, 8

7

4-7

Page 208

Model 200 Controller User’s Manual

Field

Description

Value

Default

Stop bits

The number of bits to use for setting communications protocol.

1, 2

1

Hot Standby Timeout

The number of seconds the Model 200 Controller waits for a response from the 9154 controller before it places the 9154 controller in Hot Standby mode.

1 to 9999

40

Integrity Mode

This mode determines the amount of transaction verification that the Model 200 Controller performs.

Faster, Safer

Faster

Transactions held in volatile memory

The number of transactions the controller keeps in volatile RAM before it begins to write them to a Hot Standby file.

None, Unlimited, Maximum

Maximum 50

Multi-Drop Enabled

The Multi-Drop line that the 9154 controller uses.

m, n, o, p p

To edit the parameters for a 9154 controller 1. In the Connection Point List dialog box, select the 9154 controller and then choose Add. The Setup for Controller dialog box appears. 2. In the Serial port field, click the down arrow on the right side of the field. A list of available COM ports appears. Select the COM port on the controller that connects to the 9154 controller. 3. In the Baud rate field, click the down arrow on the right side of the field. A list of baud rates appears. Select the baud rate you want to use to communicate with the 9154 controller. 4. Enable or disable the LRC check box. The LRC provides additional data integrity. 5. Choose the parity, data bits, and stop bits. These parameters must match the parameters configured in the 9154 controller.

4-8

Page 209

Connecting to the 9180 and the Intermec CrossBar Network

4

6. In the Hot Standby Timeout box, enter the number of seconds you want the Model 200 Controller to wait for a response from the 9154 controller before it places the 9154 controller in Hot Standby mode. 7. In the Integrity Mode box, choose the mode that determines the amount of transaction verification the Model 200 Controller performs. 8. In the Transactions Routed to This Controller box, choose the number of transactions you want the controller to keep in RAM before it writes them to a Hot Standby file. • Choose None if you want the transaction always written to the file. • Choose Unlimited if you don’t want the transaction written to the file unless the time you set for the Hot Standby timeout expires. • Choose Maximum and enter a maximum number of transactions. When the controller has this number of transactions in RAM, it writes them to a file. 9. Choose Time Parameters to set the time parameters for the 9154 controller. For help, see “Setting the Time Parameters” later in this section. 10. In the Multi-Drop Enabled box, choose the Multi-Drop line that the 9154 controller supports. 11. Choose OK to save your changes and return to the Connection Point List dialog box.

4-9

Page 210

Model 200 Controller User’s Manual

Adding a 9161 Controller

Field

Description

Value

Default

Serial port

The communications port to which the 9161 controller is connected.

COM1, COM2

COM1

Baud rate

The baud rate at which the serial port communicates.

Predefined

9600

LRC enabled

This check box determines if the longitudinal redundancy check character is appended to data transmitted by a device.

Check, Clear

Clear

Parity

The type of self-checking to use when sending data.

Even, Odd, None

Even

Data bits

The number of bits to use for setting communications protocol.

7, 8

7

4-10