The text of a manual · part 20 of 70
Model 200 Controller System Manual, pages 191 to 200
Pages 191 to 200 of 695
The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 0200
Page 191
Connecting to the Intermec RF Network
Field
Description
Value
Default
Broadcast enabled
This check box determines if the controller broadcsts a time to all terminals in the UDP Plus network.
Check, Clear
Clear
Interval
This field specifies how often in minutes the controller broadcasts the time.
0 to 99
1
Append enabled
This check box determines if a timestamp is added to messages from devices.
Check, Clear
Clear
Include Year
This check box adds the 4-digit year to the time.
Check, Clear
Clear
3
3-29
Page 192
Model 200 Controller User’s Manual
Field
Description
Value
Default
Include Month
This check box adds the 2-digit month to the time.
Check, Clear
Clear
Include Day
This check box adds the 2-digit day to the time.
Check, Clear
Check
Include Seconds
This check box adds a 2-digit seconds to the time.
Check, Clear
Clear
Delimiter
This character separates the data from the appended date and time.
1 alphanumeric or special character
>
Julian date
This check box determines if the date for the time is in a 3-digit Julian format.
Check, Clear
Clear
To set the time parameters 1. From the UDP Plus Network Parameters dialog box, in the Configure box, choose Time Parameters. The Configure Time Parameters dialog box appears. 2. In the Broadcast Parameters box, enable or disable the time broadcast. A check in the Broadcast enabled check box means that time broadcast is enabled. 3. In the Interval field, enter how often (in minutes) you want the controller to do a time broadcast. If you set this field to 0, no time broadcast is made. 4. In the Append Parameters box, enable or disable the time append. A check in the Append enabled check box means that there is a time appended to all messages. If you do not enable time append, skip to Step 8. 5. Enable or disable Include Year, Include Month, Include Day, Include Seconds. A check in the check box means that the part of the date or time is included in the time. 6. In the Delimiter field, click the down arrow on the right side of the field. A list of available delimiters appears. Select the delimiter that you want to use to separate the appended time from the transaction data.
3-30
Page 193
Connecting to the Intermec RF Network
3
7. Enable or disable Julian format. A check in the check box means that the date is in Julian format. Other date and time options are not used. 8. Choose OK to save your changes and return to the UDP Plus Network Parameters dialog box.
Identifying the UDP Plus Devices You need to configure the Model 200 Controller for the logical names and IP addresses of the UDP Plus terminals that use it to communicate with the host. The device list contains the logical names of all 128 terminals. The first eight names are enabled and are configured as TRAKKER 2400s. You need to enable or disable the logical names of any other terminals that you want to be available to communicate with the host. You can edit each terminal to change its logical name, IP address, device type, transaction IDs, and delivery responses. You can also use DNS to determine the device’s IP address or to edit an IP address. Your controller is licensed to communicate with a fixed number of terminals (1-8, 1-24, 1-64, 1-128). The controller does not keep track of the number of terminals you enable. You can enable all 128 terminals. As each terminal sends messages to the controller, the controller logs its logical name. When the controller logs the maximum number of logical names that your terminal license allows, it will not accept messages from any new logical names. When you stop data collection on the controller, the terminal license count number is reset. If you need to purchase an upgrade to your terminal license, contact your local Intermec representative. To identify the UDP Plus terminals 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Downline Devices. The Device List dialog box appears.
3-31
Page 194
Model 200 Controller User’s Manual
4. In the Connection field, click the down arrow on the right side of the field. A list of the connection points that you have configured appears. Select UDP Plus. 5. To enable all 128 terminals, choose Enable All. Or, to enable specific terminals, select the terminal you want to enable and make sure there is a check in the Enabled check box. Note: Each terminal must use DNS or have a valid IP v4 address before you can enable it. 6. To disable all 128 terminals, choose Disable All. Or, to disable specific terminals, select the terminal you want to disable and make sure there is no check in the Enabled check box.
3-32
Page 195
Connecting to the Intermec RF Network
3
7. Select a terminal whose individual parameters you want to edit and choose Edit Device. For help, see “Editing a UDP Plus Device” in the next section. 8. Choose OK to save your changes and return to the main menu.
Editing a UDP Plus Device Note: If you are using terminal emulation, do not configure transaction IDs or delivery responses.
3-33
Page 196
Model 200 Controller User’s Manual
Field
Description
Value
Default
Logical name
The logical name of the terminal.
1 to 16 alphanumeric characters
UDPPXXX
Able to receive data
This check box determines if this terminal can receive data from the network.
Check, Clear
Check
Device type
This list box contains all the current Intermec devices supported.
Predefined list
TRAKKER 2400
Auto-insert from this device
This field provides a transaction ID for this terminal if it cannot put a transaction ID in its transactions.
Predefined list
None
To be routed to device
This field contains a transaction ID that will always be routed to this terminal.
Predefined list
None
Interactive response (Optional)
The message that is sent to the source of the transaction if the transaction is delivered successfully to this terminal.
1 to 39 characters
None
Hot standby (Optional)
The message that is sent to the source of the transaction if the transaction for this terminal is written to a Hot Standby file.
1 to 40 characters
None
To edit a UDP Plus device 1. From the Device List dialog box, select the logical name of the terminal whose individual parameters you want to edit and choose Edit Device. The Device Parameters dialog box appears. 2. In the Logical name field, enter the logical name for the terminal that the network uses to identify it. 3. Enable or disable the check box that determines if the terminal can receive data from the network.
3-34
Page 197
Connecting to the Intermec RF Network
3
4. In the Device type field, click the down arrow on the right side of the field. A list of all the devices that can run in a UDP Plus network appears. Select a device. 5. In the Auto-insert from device field, click the down arrow on the right side of the field. A list of all the transaction IDs appears. Select the transaction ID you want to use if this terminal cannot put a transaction ID in its transactions. Note: All transactions from this terminal are routed using this transaction ID. 6. In the To be routed to device field, click the down arrow on the right side of the field. A list of all the transaction IDs appears. Select the transaction ID you want to always route to this terminal. 7. In the Delivery Responses box, enter the messages you want to send to the transaction source. • In the Interactive response field, enter the message you want sent back to the source of the transaction if the delivery of the transaction for this terminal is successful. • In the Hot standby field, enter the message you want sent back to the source of the transaction if the delivery of the transaction for this terminal is not immediately successful and is written to a Hot Standby file. 8. Resolve or edit the terminal IP address. For help, see “Determining a UDP Plus Device’s IP Address” or “Editing a UDP Plus Device’s IP Address” later in this chapter. 9. Choose OK to save your changes and return to the Device List dialog box.
3-35
Page 198
Model 200 Controller User’s Manual
Determining a UDP Plus Device’s IP Address If you are using a DNS server and you want to know the IP address of a terminal, from the Device Parameters dialog box, choose Addressing. The Device Address dialog box appears.
To determine a terminal’s IP address • (Optional) In the Domain field, enter the specific domain that contains the terminal. • Choose Resolve to look up the terminal’s IP address on the DNS server using the logical name. If you did not enter a domain, the server searches the list of domains that are configured in the DNS Configuration dialog box.
3-36
Page 199
Connecting to the Intermec RF Network
3
Editing a UDP Plus Device’s IP Address If you are not using a DNS server and you want to edit the IP address of a terminal, from the Device Parameters dialog box, choose Addressing. The Device Address dialog box appears.
To edit a terminal’s IP address 1. Clear the Use DNS check box. 2. In the IP address field, enter a new IP address for the terminal.
Saving Your Run-Time Configuration When you finish configuring your downline network, you should save your changes. To save your run-time configuration • From the main menu sidebar buttons, choose Save Configuration.
3-37
Page 200