Page 181
Connecting to the Intermec RF Network
3
6. In the To be routed to device field, click the down arrow on the right side of the field. A list of all the transaction IDs appears. Select the transaction ID you want to always route to this device. 7. In the Delivery Responses box, enter the messages you want to send to the transaction source. • In the Interactive response field, enter the message you want sent back to the source of the transaction if the delivery of the transaction for this device is successful in Interactive mode. • In the Hot standby field, enter the message you want sent back to the source of the transaction if the delivery of the transaction for this device is not immediately successful and is written to a Hot Standby file. 8. Choose OK to save your changes and return to the Controller Device List dialog box.
Connecting the Controller to the 2.4 GHz RF Network The Model 200 Controller supports communications with Intermec’s 2.4 GHz RF (UDP Plus) network through access points that are connected to the Ethernet or token ring network. You can run standard TCP/IP applications, such as FTP, with the controller. The illustration on the next page shows an example of a Model 200 Controller connected to a UDP Plus network. You can also use the controller to route any IP traffic from one subnet to the controller. For example, if the controller is connected to a twinaxial host, it can pass IP traffic from an Ethernet network to the host and back. The UDP Plus network can consist of access points communicating with various JANUS devices and TRAKKER Antares terminals. • Access points act as bridges between the Ethernet or token ring network and Intermec’s UDP Plus network. All terminals communicating in this network must have the same domain and security ID.
3-19
Page 182
Model 200 Controller User’s Manual
• TRAKKER Antares terminals, such as the T2425, are terminals with network support. The controller supports these devices using Intermec’s UDP Plus network. Follow the instructions “Configuring a UDP Plus Network” later in this chapter. • JANUS UDP Plus devices, such as the JG2020, are hand-held data collection computers with network support. The controller communicates with these devices using UDP Plus. The JANUS devices support both Novell NetWare Client for DOS and Novell LAN Workplace for DOS. Intermec recommends that you use LAN Workplace to provide the TCP/IP protocol stack.
Example: The Model 200 Controller Connected to the Intermec 2.4 GHz RF Network Host
T2425
JR2020G
JG2050 Access Point
Model 200 Controller
Ethernet 0200-029
3-20
Page 183
Connecting to the Intermec RF Network
3
Configuring a UDP Plus Network You need to configure the UDP Plus network if you want the Model 200 Controller to communicate with TRAKKER Antares terminals and JANUS devices that are using UDP Plus. Use the worksheets in Appendix E. To configure a UDP Plus network 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Connection Points. The Connection Point List dialog box appears. 4. Add, edit, or delete the UDP Plus network connection. For help, see “Adding a UDP Plus Network” in the next section. 5. Choose Close to close the dialog box and return to the main menu.
3-21
Page 184
Model 200 Controller User’s Manual
Adding a UDP Plus Network 1. In the Connection Point List dialog box, choose Add. The Add a Downline Connection Point dialog box appears. 2. In the Downline Connections list box, select UDP Plus. 3. Choose Add. The UDP Plus Network Parameters dialog box appears.
3-22
Page 185
Connecting to the Intermec RF Network
3
Field
Description
Value
Default
Lower limit
The minimum time in milliseconds the controller waits for an acknowledgment from the device before resending a transaction.
200 to 2000
300
Upper limit
The maximum time in milliseconds the controller waits for an acknowledgment from the device before resending a transaction.
2000 to 60000
5000
Retries
The number of times the controller tries to transmit to a device before it sets the device to “not responding.”
1 to 99
7
Inactivity timer
The amount of time in minutes the device can be “not responding” before it is set to “disconnected.”
0 to 3600
60
Local
The UDP port through which the controller communicates with itself.
5001 to 65535
5550
Network
The UDP port that UDP Plus uses for communication.
5001 to 65535
5555
Hot Standby Timeout
The number of seconds the controller waits for a response from a device before it writes transactions for the device to a Hot Standby file. The device receives its transactions from the Hot Standby file when it comes back online.
1 to 9999
40
Transactions held in volatile memory
The number of transactions the controller keeps in RAM before it writes the transactions to a Hot Standby file.
None, Unlimited, Maximum
Maximum 50
4. In the Acknowledgment Delay box, set the minimum and maximum limits for how long the controller waits for an acknowledgment from the device before resending a transaction. 5. In the Retries field, enter the number of times the controller tries to transmit to a device before it sets the device to “not responding.” 6. In the Inactivity timer field, enter the amount of time in minutes the device can be “not responding” before it is set to “disconnected.”
3-23
Page 186
Model 200 Controller User’s Manual
7. In the Local field, enter the number of the port the controller uses to communicate with itself. This port must be different from the network port. 8. In the Network field, enter the number of the port that the UDP Plus network uses for communication. This number must match the network port set on the devices. 9. In the Hot Standby Timeout box, enter the number of seconds the controller waits for a response from a device before it writes transactions for the terminal to a Hot Standby file. 10. In the Transactions Routed to this Controller box, choose the number of transactions you want the controller to keep in RAM before it writes them to a Hot Standby file. • Choose None if you want transactions always written to the file. • Choose Unlimited if you do not want transactions written to the file unless the time you set for the Hot Standby timeout expires. • Choose Maximum and enter a maximum number of transactions. When the controller has this number of transactions in RAM, it writes them to a file. 11. Set any time parameters for the UDP Plus network. For help, see “Setting the Time Parameters” later in this chapter. 12. Choose OK. The Setup for UDP Plus Terminals dialog box appears. Configure the IP addresses for the UDP Plus terminals. For help, see “Setting Up the UDP Plus Devices” in the next section. 13. Choose Close to return to the main menu.
3-24
Page 187
Connecting to the Intermec RF Network
3
Setting Up the UDP Plus Devices The Model 200 Controller must know the IP address for every UDP Plus terminal that it may communicate with. You can either use the controller to generate logical names for each terminal and use a DNS server to resolve the IP addresses or you can enter each terminal’s IP address. Use a DNS server If you use a DNS server, you do not need to enter the terminal’s IP address on the controller. The controller generates the logical names for the terminals and the DNS server resolves the IP addresses. However, you still need to enter the terminal’s IP address on the terminal. Enter each terminal’s IP address manually If you do not use a DNS server, you need to enter the terminal’s IP address on the controller. However, the controller can help you generate an appropriate number of sequential IP addresses. Make sure that each IP address that the controller generates for a terminal matches an IP address on a terminal.
3-25
Page 188
Model 200 Controller User’s Manual
Field
Description
Value
Default
Number of terminals to enable
The number of IP addresses you want the controller to generate.
0 to 128
8
Use DNS
This check box determines if the controller uses a DNS server to translate the logical name to an IP address.
Check, Clear
Clear
Base logical name
The base name that the controller uses to create a unique logical name for each terminal.
1 to 13 alphanumeric characters
UDPP
Starting IP address
The starting IP address that the controller uses to assign IP addresses to each terminal.
xxx.xxx.xxx.xxx where xxx is a value between 0 and 255
None
Subnet mask
The subnet mask that the controller uses to validate the IP addresses.
xxx.xxx.xxx.xxx where xxx is a value between 0 and 255
Based on starting IP address
Domain
The name of the domain that all of the terminals are in.
None
None
To set up the UDP Plus devices using a DNS server 1. In the Number of terminals to enable field, enter the number of logical names that you want the controller to generate. 2. Check the Use DNS check box. Note: Before you enable this check box, you must first configure a DNS server in the DNS Configuration dialog box. 3. In the Base logical name field, enter the base name that the controller uses to create a unique logical name for each terminal. The controller appends a sequential 3-digit number to this name for each terminal.
3-26
Page 189
Connecting to the Intermec RF Network
3
4. In the Domain field, enter the name of the domain that all of the terminals are in. Note: If you enable the Use DNS check box and you do not enter a domain, the controller searches the domains that are listed in the DNS Configuration dialog box. 5. Choose OK. The controller generates the logical names and you return to the Connection Point List dialog box.
To set up the UDP Plus devices using the controller to generate IP addresses 1. In the Number of terminals to enable field, enter the number of IP addresses that you want the controller to generate. 2. Clear the Use DNS check box. 3. In the Base logical name field, enter the base name that the controller uses to create a unique logical name for each terminal. The controller appends a sequential 3-digit number to this name for each terminal. 4. In the Starting IP address field, enter the starting IP address. The IP address must be a valid IP v4 address. 5. In the Subnet mask field, enter the subnet mask that the controller uses to validate the IP addresses. The controller verifies that they do not cross a subnet boundary. 6. Choose OK. The controller assigns valid sequential logical names and IP addresses to the terminals starting with the starting IP address and then you return to the Connection Point List dialog box.
3-27
Page 190
Model 200 Controller User’s Manual
Setting the Time Parameters Use this dialog box to configure the broadcast and append parameters between the controller and the UDP Plus terminals. Broadcast Parameters These optional parameters allow the controller to broadcast a time at certain intervals to all UDP Plus terminals. These parameters synchronize the terminals with the controller. Append Parameters These optional parameters configure the controller to stamp the date and time to incoming data. The timestamp is in the format:
delimiterYYYY:MM:DD:HH:MM:SS If you enable this feature, all messages have a timestamp with the hour and minute. You can also append the year, month, day, and seconds. Make sure that when you append the date and time to the incoming data, the maximum transaction data length will not exceed 1024 bytes. If the date and time that is appended is longer than the maximum transaction data length, the time append will be truncated. You cannot use this feature when running terminal emulation. Note: Do not enable time append on both the UDP Plus network and the terminal. If it is enabled on both, two timestamps are appended to incoming data.