Page 171

Connecting to the Intermec RF Network

3

Field

Description

Value

Default

Acknowledgment delay

The maximum amount of time in milliseconds that the RF controller card waits before it determines that the device did not receive a message.

0 to 255

100

Retry count

The number of times the RF controller card tries to transmit to a device.

0 to 255

64

BRU Status

This check box determines which BRUs are connected to the RF controller card.

Check, Clear

First BRU is checked, all others cleared.

Channel Frequency

The channel and frequency on which the BRU is communicating.

0 to 6

0. If 0 is being used, the next available value is used.

Repeat count

The number of repeaters that a message is allowed to pass through for this BRU.

0 to 7

0

Hot Standby Timeout

The number of seconds the controller waits for a response from a device before it writes transactions for the device to a Hot Standby file.

1 to 9999

40

Transactions held in volatile memory

The number of transactions the controller keeps in RAM before it writes the transactions to a Hot Standby file.

None, Unlimited, Maximum

Maximum 50

3-9

Page 172

Model 200 Controller User’s Manual

4. In the Card number field, click the arrow on the right side of the field. A list of the available RF controller cards appears. Select the RF controller card you want to configure. 5. Enter the RFNC address, network ID, acknowledgment delay, and retry count for the RF controller card. Each RF controller card must have a unique RFNC address and a unique network ID. 6. In the BRU Parameters box, enable or disable the BRUs that you want to communicate with this RF controller card. 7. In the Channel - Frequency field, click the down arrow on the right side of the field. A list of all the available channels and frequencies appears. For each BRU, select a unique channel - frequency. 8. In the Repeat count field, enter the number of repeaters each message is allowed to pass through. Note: Intermec recommends that a message does not pass through more than three repeaters. Using more than three repeaters may cause excessive delays when communicating with the terminals. 9. In the Hot Standby Timeout box, enter the number of seconds the controller waits for a response from a device before it writes transactions for the device to a Hot Standby file. 10. In the Transactions Routed to this Card box, choose the number of transactions you want the controller to keep in RAM before it writes them to a Hot Standby file. • Choose None if you want transactions always written to the file. • Choose Unlimited if you do not want transactions written to the file unless the time you set for the Hot Standby timeout expires. • Choose Maximum and enter a maximum number of transactions. When the controller has this number of transactions in RAM, it writes them to a file. 11. Choose Time Parameters to configure specific time parameters for this RF controller card. For help, see “Setting the Time Parameters” in the next section. 12. Choose OK to close this dialog box and return to the Connection Point List dialog box.

3-10

Page 173

Connecting to the Intermec RF Network

3

Setting the Time Parameters Use this dialog box to configure the broadcast and append parameters between the BRUs and their devices. Note: When the controller sends a time broadcast, it is not a guaranteed packet. Broadcast Parameters These optional parameters allow the controller to broadcast a time, with a short string, at certain intervals to all RF devices. These parameters synchronize the RF devices with the controller. Append Parameters These optional parameters configure the BRUs to stamp the date and time to incoming data. The timestamp is in the format:

delimiterYYYY:MM:DD:HH:MM:SS If you enable this feature, all messages have a timestamp with the hour and minute. You can also append the year, month, day, and seconds. Make sure that when you append the date and time to the incoming data, the maximum transaction data length will not exceed 1024 bytes. If the date and time that is appended is longer than the maximum transaction data length, the time append will be truncated. This feature will not operate when running terminal emulation or using the direct TCP/IP socket interface. Note: Do not enable time append on both the RF card and the RF device. If it is enabled on both, two timestamps are appended to incoming data.

3-11

Page 174

Model 200 Controller User’s Manual

Field

Description

Value

Default

Broadcast enabled

This check box determines if the BRUs broadcast a time to all devices communicating with them.

Check, Clear

Clear

Include Seconds

This check box adds seconds to the time.

Check, Clear

Clear

Include Date

This check box adds the date to the time.

Check, Clear

Clear

3-12

Page 175

Connecting to the Intermec RF Network

Field

Description

Value

Default

Time format

These option buttons choose the time broadcast format.

12 hour, 24 hour

12 hour

Interval

This field specifies how often in minutes the controller broadcasts the time.

0 to 99

1

Preamble

This field lets you add a short message to the beginning of the time.

1 to 5 alphanumeric characters

None

Postamble

This field lets you add a short message to the end of the time.

1 to 5 alphanumeric characters

None

Append enabled

This check box determines if a timestamp is added to messages from devices.

Check, Clear

Clear

Include Year

This check box adds the 4-digit year to the time.

Check, Clear

Clear

Include Month

This check box adds the 2-digit month to the time.

Check, Clear

Clear

Include Day

This check box adds the 2-digit day to the time.

Check, Clear

Check

Include Seconds

This check box adds 2-digit seconds to the time.

Check, Clear

Clear

Delimiter

This character separates the data from the appended date and time.

1 alphanumeric or special character

>

Julian date

This check box determines if the date is in a 3-digit Julian format.

Check, Clear

Clear

3

3-13

Page 176

Model 200 Controller User’s Manual

To set the time parameters 1. From the Setup for Controller dialog box, in the Configure box, choose Time Parameters. The Configure Time Parameters dialog box appears. 2. In the Broadcast Parameters box, enable or disable the time broadcast. A check in the Broadcast enabled check box means that time broadcast is enabled. If you do not enable time broadcast, skip to Step 8. 3. Enable or disable including seconds in the time. A check in the Include Seconds check box means that seconds are added. Note: If you are using JANUS RF devices to communicate with the BRUs, you must enable this check box. 4. Enable or disable including the date in the time. A check in the Include Date check box means that the date is added. 5. Choose the 12 Hour or 24 Hour time format button. 6. In the Interval field, enter how often (in minutes) you want the controller to do a time broadcast. If you set this field to 0, no time broadcast is made. 7. In the Preamble and Postamble fields, enter a short string you want to add before or after the time to customize it. 8. In the Append Parameters box, enable or disable the time append. A check in the Append enabled check box means that there is a time appended to all messages. If you do not enable time append, skip to Step 12. 9. Enable or disable Include Year, Include Month, Include Day, Include Seconds. A check in the check box means that the part of the date or time is included in the time. 10. In the Delimiter field, click the down arrow on the right side of the field. A list of available delimiters appears. Select the delimiter that you want to use to separate the appended time from the transaction data. 11. Enable or disable Julian format. A check in the check box means that the date is in Julian format. Other date and time options are not used. 12. Choose OK to save your changes and return to the Setup for Controller dialog box.

3-14

Page 177

Connecting to the Intermec RF Network

3

Identifying the RF Devices You need to configure the Model 200 Controller for all the devices that use it to communicate with the host. The device list contains the logical names of all 128 devices. The first eight names are enabled and are configured as JANUS 2020s. You need to enable or disable the logical names of any other devices that you want to be available to communicate with the host. Note: Do not enable devices that you are not using. If you try to send data to a nonexistent enabled device, your system performance will degrade. You can edit each device to change its logical name, device type, transaction IDs, and delivery responses. Your controller is licensed to communicate with a fixed number of data collection devices (1-8, 1-24, 1-64, 1-128). The controller does not keep track of the number of devices you enable. You can enable all 128 devices. As each device sends messages to the controller, the controller logs its logical name. When the controller logs the maximum number of logical names that your terminal license allows, it will not accept messages from any new logical names. When you stop data collection on the controller, the terminal license count number is reset. If you need to purchase an upgrade to your terminal license, contact your local Intermec representative. To identify the RF devices 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Downline Devices. The Device List dialog box appears.

3-15

Page 178

Model 200 Controller User’s Manual

4. In the Connection field, click the down arrow on the right side of the field. A list of the connection points that you have configured appears. Select the RF controller card for which you want to enable devices. 5. To enable all 128 devices, choose Enable All. Or, to enable specific devices, select the device you want to enable and make sure there is a check in the Enabled check box. 6. To disable all 128 devices, choose Disable All. Or, to disable specific devices, select the device you want to disable and make sure there is no check in the Enabled check box. 7. Select a device whose individual parameters you want to edit and then choose Edit Device. For help, see, “Editing an RF Device” in the next section. 8. Choose OK to save your changes and return to the main menu.

3-16

Page 179

Connecting to the Intermec RF Network

3

Editing an RF Device Note: If you are using terminal emulation, do not configure transaction IDs or delivery responses.

Field

Description

Value

Default

Logical name

The logical name of the device.

1 to 16 alphanumeric characters

ISA1XXX

Able to receive data

This check box determines if this device can receive data from the network.

Check, Clear

Check

Device type

This list box contains the current Intermec devices that are supported.

Predefined list

J2020

3-17

Page 180

Model 200 Controller User’s Manual

Field

Description

Value

Default

Auto-insert from device

This field provides a transaction ID for this device if it cannot put a transaction ID in its transactions.

Predefined list

None

To be routed to device

This field contains a transaction ID that will always be routed to this device.

Predefined list

None

Interactive response (Optional)

The message that is sent to the source of the transaction if the transaction is delivered successfully to this device in Interactive mode.

1 to 39 characters

None

Hot standby (Optional)

The message that is sent to the source of the transaction if the transaction for this device is written to a Hot Standby file.

1 to 40 characters

None

To edit an RF device 1. In the Device List dialog box, select a device whose individual parameters you want to edit and choose Edit Device. The Device Parameters dialog box appears. 2. In the Logical name field, enter the logical name for the device that the network uses to identify it. 3. Enable or disable the check box that determines if the device can receive data from the network. 4. In the Device type field, click the down arrow on the right side of the field. A list of all the supported Intermec devices appears. Select the type of device you are configuring. 5. In the Auto-insert from device field, click the down arrow on the right side of the field. A list of all the transaction IDs appears. Select the transaction ID you want to use if this device cannot put a transaction ID in its transactions. Note: All transactions from this terminal will be routed using this transaction ID.

3-18