Page 161

Setting Up the Controller

2

Stopping Data Collection You may need to stop data collection on your Model 200 Controller to update its configuration file. When you stop data collection, all data collection activities are stopped, but any external Intermec controllers continue polling and buffering data. Data collection devices using programs that require a response directly from a destination (interactive mode) also stop until the controller is started again. To stop data collection on the controller 1. From the main menu sidebar buttons, choose Stop Data Collection. The Stop Data Collection message box appears. 2. Choose Stop to stop data collection.

Turning Off the Controller You may need to power off the Model 200 Controller for maintenance or relocation. The controller needs to perform a series of shutdown activities, which may take up to five minutes to ensure that no system files or data are lost. To shut down the controller 1. From the main menu sidebar buttons, choose Shutdown Controller. The Shutdown Model 200 Controller message box appears. 2. Enable or disable the Save and activate changes check box depending on if you want to save any changes you have made to the configuration. 3. Choose Shutdown to shut down the controller. The controller needs to perform a series of shutdown activities, which may take up to five minutes. A message box appears letting you know when you can safely turn off the controller.

2-25

Page 162

Model 200 Controller User’s Manual

Accessing a Command Prompt While maintaining or configuring your controller, you may find your task is easier by accessing a command prompt. To access a command prompt 1. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Controller Command Prompt and then choose Start. The Command Prompt Password dialog box appears.

3. In the Password field, type: INTERMEC 4. Choose OK. The Controller Command Prompt window appears.

To close the Command Prompt window 1. Choose the box in the upper left corner of the window. A drop-down menu appears. 2. Choose Close to return to the main menu.

2-26

Page 163

3 Connecting to the Intermec RF Network

Page 164

Model 200 Controller User’s Manual

Page 165

Connecting to the Intermec RF Network

3

This chapter explains how to connect the Model 200 Controller to the 900 MHz RF network using RF controller cards and BRUs and to the UDP Plus network using access points, JANUS devices, and TRAKKER Antares terminals.

Chapter Checklist Done?

‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰

Task

Page

Connect the controller to the 900 MHz RF network.

3-4

Connect the controller to the Ethernet network.

5-5

Configure the RF controller cards in the controller to communicate with the BRUs.

3-6

Set the time parameters for the 900 MHz network.

3-11

Identify the JANUS 900 MHz RF devices.

3-15

Edit the JANUS 900 MHz RF devices.

3-17

Configure the 2.4 GHz RF (UDP Plus) network.

3-19

Set the time parameters for the UDP Plus network.

3-27

Identify the UDP Plus devices.

3-31

Edit the UDP Plus devices.

3-33

If you already understand and have performed these tasks, connect the controller to your CrossBar network or host environment as described in these chapters: • Chapter 4, “Connecting to the 9180 and the Intermec CrossBar Network” • Chapter 5, “Connecting to an Ethernet/Token Ring Network” • Chapter 6, “Connecting to a Coaxial/Twinaxial Network” • Chapter 7, “Connecting to an SDLC Network”

3-3

Page 166

Model 200 Controller User’s Manual

Connecting the Controller to the 900 MHz RF Network The Model 200 Controller can communicate with Intermec’s 900 MHz RF data collection network. To communicate with this network, the controller contains RF controller cards (up to two) that connect by an RS-422 cable to 9181 Base Radio Units (BRUs). The BRUs transmit information from the controller to Intermec RF devices and receive signals from them. The illustration on the next page shows an example of a Model 200 Controller connected to a 900 MHz RF network. Each RF controller card supports either 2-port or 4-port options so you can connect up to seven BRUs in an Intermec 900 MHz data collection network. Before you configure the RF controller card, you should do the following: • Configure the host connection. • Install the 9181 BRUs, JANUS RF devices, and any other Intermec RF devices. Note: If you are using the 9180 Network Controller to communicate with the 9181 BRU, you need to configure these BRUs using the 9180 controller’s configuration menu. Refer to your 9180 user’s manual. To connect the Model 200 Controller and the BRU, you need to know if you have 2-port or 4-port RF controller cards in the controller. Cables must be ordered separately. • If you have a 2-port card, you need an Intermec cable kit (Intermec P/N 055003) or equivalent. You also need a Belden 89688 cable (Intermec P/N 583326) or equivalent. • If you have a 4-port card, Intermec provides you with a 4-port interface cable. Insert one end of the cable into the port on the RF controller card. Use Intermec cable kit (Intermec P/N 055003) or equivalent to connect to one of the DNLN ports on the other end of the cable. You also need a Belden 89688 cable (Intermec P/N 583326) or equivalent.

3-4

Page 167

Connecting to the Intermec RF Network

3

Example: The Model 200 Controller Connected to the Intermec 900 MHz RF Network Host

- 48 RS

85

-4

RS

5

Model 200

9181 9181

9450 J2050 9189 9465

RS-232

JR2020

3400

0200-028

3-5

Page 168

Model 200 Controller User’s Manual

Configuring RF Controller Cards You need to configure the communications parameters, enable the BRUs, set the Hot Standby timeout, and set any special time parameters for the RF controller cards. Use the worksheets in Appendix E. Communication Parameters These required parameters set the attributes of the RF controller cards. You need to set these parameters so the devices can transmit messages to the controller and the controller can send messages to the devices. Each RF controller card must have a unique RFNC address and a unique network ID. BRU Parameters These required parameters set the attributes of the BRUs that are connected to the RF controller cards. Identify which BRUs should be enabled, set each BRU to a unique channel/frequency, and choose the number of hops each message is allowed. Hot Standby Timeout This required parameter sets the amount of time the controller waits to receive an acknowledgment after delivering a transaction to a data collection device. If it does not receive an acknowledgment, the controller writes the transactions for the device to a Hot Standby file. The device receives its transactions from this file when it comes back online. Transactions Routed to This Card box This required parameter lets you choose the number of transactions you want the server to keep in volatile RAM before it begins to write them to a Hot Standby file.

3-6

Page 169

Connecting to the Intermec RF Network

3

To configure the RF controller card 1. From the main menu, choose the type of communication you are using to connect the controller to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Connection Points. The Connection Point List dialog box appears. 4. Add, edit, or delete RF controller card connections. For help, see “Adding RF Controller Cards and BRUs” in the next section. 5. Choose Close to close the dialog box and return to the main menu.

Adding RF Controller Card and BRUs 1. In the Connection Point List dialog box, choose Add. The Add a Downline Connection Point dialog box appears. 2. In the Downline Connections list box, select the RF card you want to add. 3. Choose Add. The Setup for Controller: RF Card dialog box appears.

3-7

Page 170

Model 200 Controller User’s Manual

Field

Description

Value

Default

Card number

The RF controller card that you want to configure.

1, 2

1

RFNC address

The radio frequency network address of the RF controller card. Devices use this address to communicate with the BRUs attached to this card.

0 to 63

0. If 0 is being used, the next available value is used.

Network ID

The network ID of the RF controller card. Devices use this ID during a channel search to locate the RF controller card’s RFNC address.

1 to 254

1. If 1 is being used, the next available value is used.

3-8