Page 151

Setting Up the Controller

2

Field

Description

Value

Default

Send to downline devices every...

This check box determines if the Model 200 Controller sends its time to all external Intermec controllers.

Check, Clear

Check

...minutes

This field specifies how often in minutes the controller sends the time synchronization message.

0 to 9999

60

File Transfer Time

This box specifies how long in seconds the controller waits for a response from the data collection device when it is downloading files before it times out.

0 to 9999

180

ID delimiter

The character that the data collection devices use to separate the transaction ID from the transaction fields.

Predefined

, (comma)

Bad ID response (Optional)

The message that the controller sends to the source of the transaction if the controller does not recognize the transaction ID.

1 to 39 characters

None

Maximum connections (Peer-to-peer)

A tuning value that defines the maximum number of connections for each NetComm process.

1 to 256

10

Strip pad (Peer-to-peer, APPC only)

The pad character, which is used by fixed-length transactions from a host application, that you want the controller to remove before sending the transaction.

Predefined

None

Auto-Start

This check box determines if the controller starts data collection when it is booted.

Check, Clear

Clear

Terminal Emulation Setup Screens (Optional)

This box allows you to customize which terminal emulation buttons appear in the main menu.

VT/ANSI, 5250, 3270

All

2-15

Page 152

Model 200 Controller User’s Manual

To set the system parameters 1. From the main menu sidebar buttons, choose System Parameters. The System Parameters dialog box appears. 2. Enable or disable time synchronization. A check in the check box indicates that time synchronization is enabled. Enter how often (in minutes) you want the controller to send the time broadcast to all external Intermec controllers. 3. In the File Transfer Time box, enter the number of seconds the controller waits for a response from a device when it is downloading files to that device, before it times out. 4. In the ID delimiter field, click the down arrow on the right side of the field. A list of available delimiters appears. Select the delimiter that you want to use to separate the transaction ID from the rest of the transaction fields in data coming from data collection devices. 5. (Optional) In the Bad ID response field, enter the message that you want sent back to the source of the transaction if the controller does not recognize the transaction ID. 6. (Peer-to-peer applications) In the Peer-to-Peer Network Connection Parameters box, enter the maximum number of connections for each NetComm process. 7. (Peer-to-peer applications, APPC only) In the Strip pad field, click the down arrow on the right side of the field. A list of characters that a host application may use to pad fixed-length transactions appears. Select the character that the controller removes before sending on the transaction. 8. In the Auto-Start box, enable or disable the controller from automatically starting data collection when it boots. A check in the check box enables this feature. 9. (Optional) In the Terminal Emulation Setup Screens box, choose which type of terminal emulation you want displayed in the main menu. 10. Choose OK to save your changes and return to the main menu.

2-16

Page 153

Setting Up the Controller

2

About the Configuration Files The Model 200 Controller uses three configuration files: Default This configuration is the factory default configuration. If you want to restore the default configuration, for example you may want to move the controller to a new system, select this option. For help, see “Restoring Default Configuration” in the next section. Current When you choose Save Configuration, the controller updates the current configuration file. The controller does not change the active configuration file. Having separate files for the current and active configurations lets you make changes while the controller is running without interrupting data collection. Active When you choose Save and Activate, the controller copies the current configuration file to the active configuration file. The active configuration file is the file that the controller uses when you choose Start Data Collection.

Restoring Default Configuration This procedure restores the factory default configuration of the Model 200 Controller. If you want to load your backed up system files or run-time configuration, see “Restoring Your System Files and Run-Time Configuration” or “Restoring Your User Files” later in this chapter. To restore the default configuration 1. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select Reset to Factory Defaults and then choose Start. The Reset to Factory Defaults message box appears. 3. Choose Reset Controller to reset the factory defaults and return to the main menu. 4. Choose Save and Activate to make the default configuration the active configuration.

2-17

Page 154

Model 200 Controller User’s Manual

5. Choose Shutdown Controller to shut down the controller. 6. Press Ctrl-Alt-Del to reboot the controller.

Backing Up the Controller Configuration Once you have configured your Intermec hardware, have set up your host communications, and have set up your host environment parameters, you can start data collection on your Model 200 Controller. Intermec recommends that you back up your system files and your run-time configuration before you start data collection.

Backing Up Your System Files and Run-Time Configuration When you open the Model 200 Controller package, unpack the blank, formatted, 3.5-inch disk. Use this disk to back up your system files and runtime configuration. If your controller loses its configuration, you can use these files to restore the controller. To back up the configuration 1. Insert the 3.5-inch disk into the controller disk drive. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. In the System Maintenance list box, select Backup System Files and then choose Start. The Backup System Files message box appears. 4. Choose Backup Files. The controller backs up the system files and runtime configuration. 5. Remove your disk from the disk drive, label it, and put it in a safe place. 6. From the System Maintenance dialog box, choose Close to return to the main menu.

2-18

Page 155

Setting Up the Controller

2

Backing Up Your User Files You must back up any user files so that you can restore them if your controller loses its configuration. For example, if you are using screen mapping, you may want to back up your script (.SCR) and template (.TPL) files. You may also want to back up the NGERROR.LOG file, which contains controller error messages. Note: When backing up your user files, you need to use a separate 3.5-inch disk from the one you used to back up your run-time configuration. To back up your user files 1. Insert a 3.5-inch disk into the controller disk drive. 2. From the main menu sidebar buttons, choose File Handling. The File Handling dialog box appears. 3. In the File Handling list box, select Backup User Files and then choose Start. The Backup User Files dialog box appears.

4. In the root directory list box (\), add all the files that you want to back up to the Selected Files list box. a. Select the file name. Script files are in the subdirectory SCRIPTS. Template files are in the subdirectory TPL. b. Choose Select. The file name appears in the Selected Files list box.

2-19

Page 156

Model 200 Controller User’s Manual

5. In the Selected Files list box, remove any files that you do not want to back up. a. Select the file name. b. Choose Remove. The file name is removed from the Selected Files list box. 6. Choose Backup Files. The controller backs up the user files you selected. 7. Remove your disk from the disk drive, label it, and put it in a safe place. 8. From the File Handling dialog box, choose Close to return to the main menu.

Restoring the Controller Configuration If your Model 200 Controller loses its configuration, you can recover the system files and run-time configuration.

Restoring Your System Files and Run-Time Configuration 1. Insert the 3.5-inch disk that contains the system files and run-time configuration backup into the controller disk drive. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. In the System Maintenance list box, select Restore System Files and then choose Start. The Restore System Files message box appears. 4. Choose Restore Files. The controller restores the system files and runtime configuration and then shuts down. 5. Remove your disk from the disk drive and put it in a safe place. 6. Press Ctrl-Alt-Del to reboot the controller.

2-20

Page 157

Setting Up the Controller

2

Restoring Your User Files You can also use this feature to transfer files, such as validation files or applications, from a floppy disk to the controller. To restore your user files 1. Insert the 3.5-inch disk that contains the backup of your user files into the controller disk drive. 2. From the main menu sidebar buttons, choose File Handling. The File Handling dialog box appears. 3. In the File Handling list box, select Restore User Files and then choose Start. A message box appears with instructions to insert the disk in the drive of the controller. 4. Choose OK. The Restore User Files dialog box appears. The files on the floppy disk appear in the Available Files list box.

2-21

Page 158

Model 200 Controller User’s Manual

5. In the Available Files list box, add all the files that you want to restore to the Selected Files list box. a. Select the file name. b. Choose Select. The file name appears in the Selected Files list box. 6. In the Selected Files list box, remove any of the files that you do not want to restore. a. Select the file name. b. Choose Remove. The file name is removed from the Selected Files list box. 7. Choose Restore Files. The controller restores the files you selected. 8. Remove your disk from the disk drive and put it in a safe place. 9. From the File Handling dialog box, choose Close to return to the main menu.

2-22

Page 159

Setting Up the Controller

2

Deleting User Files 1. From the main menu sidebar buttons, choose File Handling. The File Handling dialog box appears. 2. In the File Handling list box, select Delete User Files and then choose Start. The Delete User Files dialog box appears.

3. In the root directory list box (\), add all the files that you want to delete to the Selected Files list box. a. Select the file name. b. Choose Select. The file name appears in the Selected Files list box. 4. In the Selected Files list box, remove any the files that you do not want to delete. a. Select the file name. b. Choose Remove. The file name is removed from the Selected Files list box. 5. Choose Delete Files. A message box appears confirming that you want to delete the files. 6. Choose Delete. The controller deletes the user files you selected. 7. From the File Handling dialog box, choose Close to return to the main menu.

2-23

Page 160

Model 200 Controller User’s Manual

Using the Controller To use the Model 200 Controller, you need to know how to start and stop data collection and shut down the controller. Caution Always choose Shutdown Controller before rebooting or turning off the controller. If you do not shut down the controller properly, you may lose data or damage files on the controller. Conseil Choisissez toujours le bouton Shutdown Controller dans l’encadré avant de réamorcer ou de fermer l’unité de contrôle. Si vous ne fermez pas correctement l’unité de contrôle, vous risquez de perdre des données ou d’endommager les fichiers sur l’unité de contrôle.

Starting Data Collection 1. From the main menu sidebar buttons, choose Save and Activate. A message box appears confirming that you want to save your changes and activate the configuration. 2. Choose Activate. A message box may appear informing you that the server needs to reboot and that you need to choose OK. Or, a message box may appear informing you that your activate is successful. 3. From the main menu sidebar buttons, choose Start Data Collection. The Start Data Collection message box appears. 4. Choose Start to start data collection.

2-24