Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 70

Model 200 Controller System Manual, pages 141 to 150

Pages 141 to 150 of 695

The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 0200

Page 141

Setting Up the Controller

2

Plugging In the Keyboard You may need to use the keyboard to enter information when using the GUI to configure the Model 200 Controller.

Equipment • Keyboard (standard) To plug in the keyboard 1. Locate the keyboard port on the rear panel of the controller. 2. Insert the keyboard connector into the keyboard port.

VIDE

LPT BD

MOU

O

1

SE

KEY

110V

1

LPT

KE

D YB

E

US

MO

0200-006

2-5

Page 142

Model 200 Controller User’s Manual

Plugging In the Mouse The mouse makes it easier for you to move around in the GUI when configuring the Model 200 Controller. Note: You must have the mouse plugged into the controller whenever you boot the controller.

Equipment Required • Mouse (standard) To plug in the mouse 1. Locate the mouse port on the rear panel of the controller. 2. Insert the mouse connector into the mouse port.

EO

VID

1

VID

LPT D

YB

MO

US

E

1

LPT

EO

SE

U MO

KE

110V

0200-007

2-6

Page 143

Setting Up the Controller

2

Connecting the Monitor Equipment • Monitor with cable and power cord (not provided) To connect the monitor to the controller 1. Locate the video port on the rear panel of the controller. 2. Insert one end of the monitor’s cable into the video port. 3. Insert one end of the power cord into the monitor and the other end into an AC power outlet.

EO

VID

LPT1

EO

VID

1

LPT

KE

YB

D

E

US

MO

110V

To AC power

0200-008

2-7

Page 144

Model 200 Controller User’s Manual

Connecting an Uninterruptable Power Supply Intermec strongly recommends that you connect an uninterruptable power supply (UPS) to your Model 200 Controller. In case of a power failure, the UPS provides enough backup power to allow the Model 200 Controller to properly shut down and minimize the loss of data. If you experience a power failure after installing a UPS, these events will occur: • If power returns within 45 seconds, no error message is logged and no message appears on the monitor. • If power does not return within 45 seconds, an error message is logged and this message appears on the monitor. Power failure. UPS is running on battery power. Stopping data collection to preserve data integrity. Controller shutdown will occur in approx 5 minutes. When data collection is stopped, the controller tries to shut down. Five minutes after the error message is logged, the UPS cuts off power to the controller. You can configure the controller to automatically restart data collection when power returns. For help, see “Setting the System Parameters” later in this chapter.

Equipment • Uninterruptable power supply, U.S. and Canada (Intermec Part No. 589082) Or, Uninterruptable power supply, International (Intermec Part No. 589079) • Cable for auto-restoration (Intermec Part No. 589157)

2-8

Page 145

Setting Up the Controller

2

To connect a UPS to the controller 1. Make sure the power is off. The power indicator should be off. 2. Insert the controller power cord’s 3-pin connector into the AC in receptacle. 3. Plug the other end of the power cord into the UPS. 4. (Optional) Intermec recommends that you use a surge protector. Plug the power cord of the UPS into the surge protector or an AC power outlet. 5. Insert one end of the serial cable into the serial port on the UPS. 6. Insert the other end of the serial cable into a COM port on the controller. 7. Set the voltage select switch to 110V or 220V. 8. Press the power button on the controller. The power indicator turns on. The main menu appears. 9. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 10. In the System Maintenance list box, choose Install Accessories and then choose Start. The Install Accessories dialog box appears.

11. Choose UPS. 12. In the Available Ports list box, select the serial port on the Model 200 Controller that you used to connect to the UPS.

2-9

Page 146

Model 200 Controller User’s Manual

13. Choose OK to save your changes. You return to the System Maintenance dialog box. 14. Choose Close to return to the main menu.

Uninterruptable power supply

EO

VID

1

LPT D

YB

E

US

MO

KE

110V

To AC power 0200-009

2-10

Page 147

Setting Up the Controller

2

Connecting a Modem You may want to connect your Model 200 Controller to a modem. If you have remote console support enabled on your server, you may want to use a modem to let you access the controller GUI using a PC with a modem. Note: You can also use the remote console support feature through a LAN or a WAN connection.

Equipment • Modem with telephone cable and power cord, U.S. and Canada (Intermec Part No. 590201) • Serial cable to connect the modem to the Model 200 Controller (Intermec Part No. 589182) To attach a modem to the controller 1. Make sure the power is off. The power indicator should be off. 2. Plug one end of the modem power cord into the modem and the other end into the AC power outlet. 3. Plug one end of the telephone cable into the modem and the other end into an RJ-11 telephone jack. 4. Insert one end of the serial cable into the serial port on the modem. 5. Insert the other end of the serial cable into a COM port on the controller. 6. Press the power button on the controller. The power indicator turns on. The main menu appears. 7. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears.

2-11

Page 148

Model 200 Controller User’s Manual

8. In the System Maintenance list box, select Install Accessories and then choose Start. The Install Accessories dialog box appears.

9. Choose Modem. 10. In the Available Ports list box, select the serial port on the Model 200 Controller that you used to connect to the modem. 11. Choose OK to save your changes. You return to the System Maintenance dialog box. 12. Choose Close to return to the main menu.

2-12

Page 149

Setting Up the Controller

2

Connecting the Model 200 Controller to a Modem

EO

VID

1

LPT D

YB

E

US

MO

KE

110V

To phone line

To AC power 0200-014

2-13

Page 150

Model 200 Controller User’s Manual

Setting the System Parameters When you set system parameters, you are defining the operating parameters for the Model 200 Controller. Time Synchronization This optional parameter causes the Model 200 Controller to send a time broadcast at certain intervals to all external Intermec controllers. Note: The time broadcast is not necessarily sent to the data collection devices that are connected to the external Intermec controllers. However, when you configure a controller, you can configure it to broadcast the time to its devices. Transaction Parameters These optional parameters make sure that the system knows the delimiter that separates the transaction ID from the transaction fields. Use the Bad ID response field if you want to make sure that there is always a response for a failed delivery of a transaction. Peer-to-Peer Network Connection Parameters These required parameters tell the controller how to set up network connections in a peer-to-peer environment.

2-14