For the Intermec 0200

Page 131

Model 200 Controller User’s Manual

Data Integrity Modes The Model 200 Controller operates in one of two data integrity modes for external Intermec controllers: Faster and Safer. You define the data integrity mode for each external controller that the Model 200 Controller uses to communicate with devices (such as terminals, readers, and printers). For more information, see the DCS 300 Technical Reference Manual. Note: These data integrity modes are provided in addition to the normal data integrity measures that are built into the Model 200 Controller.

Faster Mode Faster mode is the default integrity mode. The advantage of Faster mode is speed: the external controller can forward data to the Model 200 Controller faster than in Safer mode. The disadvantage is a small risk that transactions will be lost if the Model 200 Controller loses power.

Safer Mode Safer mode provides extra data integrity for both interactive and noninteractive devices. The advantage of Safer mode is extra security: the external controller retains its copy of the transaction until the transaction reaches either the application or the Hot Standby file. The disadvantage is that the external controller cannot forward another transaction from any device until the current transaction has been acknowledged. Note: The out-of-box protocol for the external Intermec controllers contains a 60-second transmission timeout. This means that when the controller delivers data to the DevComm, it waits 60 seconds for an acknowledgment. If the acknowledgment is not received within this time, the data is sent again to the DevComm, creating duplicate data. One solution to this is to set the controller timeout to zero, which disables the timeout.

1-28

Page 132

Learning About the Controller

1

Retaining Transactions in Memory AUX_Q is an auxiliary queue in volatile memory. By default, the Model 200 Controller uses this queue as a temporary holding place for transactions that are waiting to be sent to a destination while the controller is waiting for an ACK from that destination. AUX_Q is used only in this situation: • The controller sends a transaction to a destination, the Hot Standby timeout begins counting down, and the controller waits for an ACK. • While waiting, the controller receives another transaction for the destination. The controller cannot send the transaction until it receives an ACK for the last transaction, so the controller writes both transactions to AUX_Q. • All other transactions that subsequently arrive for the destination are written to AUX_Q. • If the controller receives the ACK before the Hot Standby timeout expires, the controller sends the transactions in FIFO order from AUX_Q to the destination. • If the controller does not receive the ACK before the Hot Standby timeout expires, the controller writes the contents of AUX_Q to the Hot Standby file. You can specify the number of transactions the controller can hold in AUX_Q for each application and DevComm before it writes the transactions to a Hot Standby file. To do this, use the GUI to set the Transactions held in volatile memory parameter on the Peer-to-Peer Destination Parameters dialog box to one of these values: None Transactions in AUX_Q are not entirely safe because they are held in volatile memory. You can keep the controller from using AUX_Q by setting the parameter to None, which forces the controller to write every transaction for a destination to that destination’s Hot Standby file. Unlimited An unlimited number of transactions can be written to AUX_Q until either the Hot Standby timeout expires or the controller sends all the transactions to the destination. Maximum (1 to 9999) When AUX_Q reaches its limit, the contents are written to the Hot Standby file. The default for this parameter is 50.

1-29

Page 133

Model 200 Controller User’s Manual

How the Controller Sets Application Status When the Model 200 Controller is initialized or first starts up, all application channels listed in the configuration file are assumed to be nonactive or batch destinations. This means that until otherwise notified, the message handler automatically routes transactions for these applications to Hot Standby files. Applications control their active and nonactive status by sending one of these system transactions: Inter

This system transaction places the application in an active state.

NoInter This system transaction places the application in a nonactive, Hot Standby state. When an application is active, the controller waits for an ACK transaction for the duration of the Hot Standby timeout. If an ACK is not received within the timeout period, the controller automatically places the application in a nonactive, Hot Standby state. During a controller shutdown, the message handler saves the status (active or nonactive) and the last message number of each application with which it was communicating. Applications that acknowledged all transactions before shutdown are considered active by the controller. The next time the controller starts, active applications are immediately sent a DcmRsmTran system transaction while nonactive applications are sent nothing. If the status file does not exist when the message handler starts, it assumes that all configured applications are nonactive. Note: The term “nonactive” with respect to an application is not the same as “noninteractive” with respect to a device.

1-30

Page 134

Learning About the Controller

1

Active Applications An active application completes a handshake with the Model 200 Controller for each transaction it receives. The message handler ensures that data is secure by requiring an ACK transaction from the application receiving the data. The controller can deliver only one transaction at a time to each application. Before the controller delivers a second transaction to a destination, the remote application must take responsibility for the current transaction by sending an ACK transaction. The controller waits for the ACK transaction for the length of time specified in the Hot Standby timeout. While waiting, the message handler keeps a copy of the original transaction. During this waiting period, the message handler continues to read and process new transactions from the Receive channel. If any of the new transactions are for the application that has not acknowledged the last transaction, these new transactions are saved locally in AUX_Q. As soon as the ACK transaction is received, the stored copy of the delivered transaction is deleted and a new transaction is sent to the application. The message handler creates one AUX_Q for each application. Note: If an application sends a Inter system transaction instead of an acknowledgment to the message handler, the message handler retransmits the last transaction it sent to that application.

Nonactive Applications A nonactive application has failed to complete the handshake with the Model 200 Controller for a transaction. An application becomes nonactive in these two situations: • If the Hot Standby timeout expires before the controller received an ACK from the application, the controller places the application in a nonactive state. Also, the controller writes all subsequent transactions for the application in a Hot Standby file. • If the number of transactions in the application’s AUX_Q reaches its limit, the controller places the application in a nonactive state. Also, the controller writes the contents of AUX_Q and all new transactions for the application into the Hot Standby file.

1-31

Page 135

Model 200 Controller User’s Manual

Sending Hot Standby Messages When the controller receives a transaction for a nonactive application, it can send a user-defined response to the device that was the source of the transaction. This optional, user-defined response is known as the Hot Standby message. You can use the GUI to configure a Hot Standby message for each transaction ID. The Hot Standby message can serve as a positive response to a device by indicating that the transaction was saved on disk. Note: If the controller does not recognize the transaction ID, the controller sends a bad ID response to the source of the invalid transaction. You configure this bad transaction ID response in the System Parameters dialog box in the GUI. If the Hot Standby message field is empty, the controller sends nothing to the device when it saves a transaction on disk. It is the application’s responsibility to return a response to a device when it receives the transaction. A response may not be required, for example, when receiving status transactions from printers. If the transaction is from a bar code reader that is operating in computer response required mode, the reader remains locked until a response is received or the reader times out. Therefore, when readers are configured this way, it is better to have the controller reply with the Hot Standby message when it cannot deliver a transaction to the application. Because transactions can have multiple routes, the controller appends a comma to the end of a Hot Standby message followed by the name of the destination where the Hot Standby response is being sent. For example, you can define a transaction ID named TRANID1 that gets routed to three destinations (selftest, writeit, and batchit) and has the following Hot Standby message, “Data saved on disk.” When the message handler receives a TRANID1 transaction from a device, the message handler sends a copy of the transaction to each of the defined destinations and starts a Hot Standby timer for each one. If writeit and batchit do not acknowledge the transaction before they go nonactive, the message handler sends these strings to the device that originated the transaction: Data saved on disk, writeit Data saved on disk, batchit

1-32

Page 136

Learning About the Controller

1

Changing from Nonactive to Active Status When an application is nonactive, only two events allow it to become active: • The application sends an ACK transaction for the most recently delivered transaction. In this case, the next transaction waiting is sent. • The application sends a Inter system transaction. In this case, if the last transaction sent to the application was not acknowledged, sending Inter causes the transaction to be retransmitted.

Active Recovery Mode Before entering a fully active state, the application goes through a recovery period, called Active Recovery mode. The Model 200 Controller takes transactions from the application’s Hot Standby file and sends them in chronological (FIFO) order to the application. The application must acknowledge each transaction just as if it were active. From the application’s point of view, it is an active application. To determine if the application is in Active Recovery mode, examine the batch flag in the transaction header. The batch flag is set to B on all transactions stored in the Hot Standby file prior to being forwarded to the application channel. New transactions sent to an application in an Active Recovery mode are still sent to the Hot Standby file. From the device’s point of view, the application is in Hot Standby mode. If the application is designed correctly for the data collection system, it should eventually be able to take delivery of all transactions in the Hot Standby file and resume interactivity with the device. At this point, the new transactions are no longer sent to the Hot Standby file. They are stored in AUX_Q until the application acknowledges or confirms responsibility for the transaction. After the acknowledgment or confirmation, the application is then active. Note: Data in an ACK transaction is ignored and not sent to the originator of the transaction if the transaction came from the Hot Standby file.

1-33

Page 137

Model 200 Controller User’s Manual

Page 138

2 Setting Up the Controller

Page 139

Setting Up the Controller

2

This chapter explains how to set up the hardware for your controller, configure the system parameters, and perform basic maintenance on your files.

Chapter Checklist Done?

‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰

Task

Page

Plug in the power cord.

2-4

Plug in the keyboard.

2-5

Plug in the mouse.

2-6

Connect the monitor to the controller.

2-7

Connect the uninterruptable power supply to the controller.

2-8

Connect the modem to the controller.

2-11

Set the system parameters on the controller.

2-14

Understand the configuration files and how to restore your default configuration.

2-17

Understand how to back up and restore the system and user files on your controller.

2-18

Understand how to start data collection, stop data collection, and shut down the controller.

2-24

If you already understand and have performed these tasks, connect the controller to your Intermec data collection network as described in these chapters: • Chapter 3, “Connecting to the Intermec RF Network” • Chapter 4, “Connecting to the 9180 and the Intermec CrossBar Network”

2-3

Page 140

Model 200 Controller User’s Manual

Plugging In the Power Cord You need to attach the power cord before you can run the Model 200 Controller. However, you may want to plug the power cord into an uninterruptable power supply (UPS). Intermec requires that you use a surge protector in locations that use 115 VAC. Intermec recommends that you use a UPS in locations that have wide variations in AC power. For help, see “Connecting an Uninterruptable Power Supply” later in this chapter.

WARNING

Warning Before connecting the power cord, make sure that the controller power switch is off. Failure to comply could result in injury due to electrical shock. Avertissement Avant de faire la connexion de la source de courant, assurez-vous que le commutateur soit “Off.” Faute de quoi vous risquez une blessure comme un choc électrique.

Equipment • Power cord, 110V U.S. cord (standard) Or, Power cord, 240V (Intermec Part No. 586266) Power cord, 250V (Intermec Part No. 586267) • Surge protector To connect the power cord to the controller 1. Locate the AC in receptacle on the rear panel of the controller. 2. Insert the power cord’s 3-pin connector into the AC in receptacle. 3. Intermec recommends that you use a surge protector. Plug the surge protector into the AC power outlet. 4. Set the voltage select switch to 110V or 220V. 5. Plug the power cord into an AC power outlet or surge protector.

2-4