Page 81

Chapter 7

Diagnostic Menu 7.1

Overview This chapter describes the diagnostic tests that the customer can perform on the Ingenico 6500. The diagnostic tests allow you to isolate failures in field-installed Ingenico 6500 units. These tests are part of the operating system and are not changed by applications. The diagnostics are menu-driven with features that allow a logical progression through the tests. Once a test is selected, a test or a series of tests will be performed on the selected entity. The result of the test will be displayed to facilitate diagnosis of the malfunctioning parts.

7.2

Testing the Display Contrast To change the display contrast, see Changing the Display Contrast on page 12. To test the display contrast, follow this procedure. This test tests all pixels to see if they are working.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Display.

The pixels are tested to determine if any are not working, or are stuck on. The unit goes through the following sequence: All pixels on – White screen displays. Every other pixel off – Light gray screen displays. All pixels off – Dark gray screen displays. Every other pixel on – Light gray screen displays.

Ingenico 6500 User’s Guide

73

Page 82

Testing the Keypad

7.3

This allows you to test each key to ensure the proper value returns.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Keypad 0 (0x30) To exit, press “CAN”

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Keypad.

Press a key to test. (Here, we pressed 0). The key value and hexadecimal value stored in the terminal’s memory returns. When finished, press [CAN].

Testing the Beeper

7.4

This feature tests the beeper by sounding and displaying each possible beep type.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper

74

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Beeper.

Chapter 7 Diagnostic Menu Section 7.3 Testing the Keypad

Page 83

Beeper Length of beep: Click/Short/Long Frequency of beep: Low/Midtone/High

7.5

The terminal displays and sounds each possible beep type.

Testing the RS232 Connection This feature tests the RS232 connection.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 RS232 COM1 COM2 RS232 Host 19200, None, 8 Test

Ingenico 6500 User’s Guide

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select RS232.

Select the communications port to test.

The results of the test display. Press [Can] to exit.

75

Page 84

Testing the RS485 Tailgate Connection

7.6

This feature tests the RS485 Tailgate connection on the HOST port.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate Tailgate IBM 46xx Test 2A23 (0x68)

76

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Tailgate.

The results of the test display. To exit, press [Can].

Chapter 7 Diagnostic Menu Section 7.6 Testing the RS485 Tailgate Connection

Page 85

7.7

Testing the USB Port This feature tests the USB connection.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select USB.

USB Diagnostic Connect USB Port OK Start PC App then Push OK Key to send

1. From the HOST, start uloop.exe.

USB Diagnostic MESSAGE n Send . . .

The results of the test display. To exit, press [Can].

Ingenico 6500 User’s Guide

2. From the terminal, press [Enter].

77

Page 86

Testing the Magnetic Stripe Reader

7.8

This feature tests the magnetic stripe reader.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader

78

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Mag Stripe Reader.

Mag Stripe Reader Swipe Card Now

Swipe a magnetic stripe card.

Mag Stripe Reader 3 tracks read, track 1 Info: isoTrackNumber=4, isoStatus=ffffebff isoLength=0

The terminal displays the results of the test for each track.

Chapter 7 Diagnostic Menu Section 7.8 Testing the Magnetic Stripe Reader

Page 87

7.9

Testing the Smart Card Reader This feature tests the smart card reader.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Smart Card Reader.

Smart Card Reader Insert Card Now

Insert a smart card.

Smart Card Reader SynchXXX card

The terminal displays the results of the smart card test.

Smart Card Reader Please remove the card!

Remove the card.

Ingenico 6500 User’s Guide

79

Page 88

Testing the SAMs

7.10

This feature tests communication between the SAM slots and the SAM micro-controller (SMC).

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select SAM.

SAM Found SAM Slot1. Found SAM Slot2. Found SAM Slot3. Found SAM Slot4.

80

SAM Check Slot2 ATR Read data from Slot2 (Result)

ATR means answer to reset.

SAM Power off all slots Close all smc slots

SMC stands for SAM micro-controller.

Chapter 7 Diagnostic Menu Section 7.10 Testing the SAMs

Page 89

7.11

Testing the Touch Screen This feature displays a grid. When you touch anywhere on the screen, a box on the grid is darkened. This test is for the i6550 only.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen

Press [ ], [Enter] to select Diagnostic Menu.

Press [ ], [Enter] to select Touch Screen.

This feature displays a grid. When you tap the screen, a box on the grid is darkened to let you know where you tapped. This allows you to test a portion of the screen you suspect may be having problems. Note: To return to the previous menu, tap the X in the top left corner.

Ingenico 6500 User’s Guide

81

Page 90

Testing Signature Capture

7.12

This feature displays a signature capture screen, so you can test how a signature inks and displays on the screen. This test is for the i6550 only.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu

Press [ ], [Enter] to select Diagnostic Menu.

Diagnostic Menu

Press [ ], [Enter] to select Signature Capture.

Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen Signature Capture OK

CANCEL

This feature displays a signature capture screen, so you can test how a signature inks and displays on the screen. When finished, tap OK.

82

Chapter 7 Diagnostic Menu Section 7.12 Testing Signature Capture

Page 91

7.13

Testing Pen Calibration If your terminal is not correctly interpreting pen touches, use this test to adjust the pen calibration. This test is for the i6550 only.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu

Press [ ], [Enter] to select Diagnostic Menu.

Diagnostic Menu

Press [ ], [Enter] to select Pen Calibration.

Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen Signature Capture Pen Calibration Please remove hands/objects from around the display Calibration will start in 3 seconds… Calibrate Pen Please tap box

Ingenico 6500 User’s Guide

Using the stylus, tap the four-box grid. The box moves around to the next corner; tap again. Repeat until you are notified if the test was successful.

83

Page 92

Calibrate Pen

You are notified if the calibration succeeded or failed.

Calibration Succeeded!

Testing Finger Calibration

7.14

If your terminal is not correctly interpreting finger touches, use this test to adjust the finger calibration. This test is for the i6550 only.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu Diagnostic Menu

Press [ ], [Enter] to select Diagnostic Menu.

Diagnostic Menu Display Keypad Beeper RS232 Tailgate USB Mag Stripe Reader Smart Card Reader SAM Touch Screen Signature Capture Pen Calibration Finger Calibration

Press [ ], [Enter] to select Finger Calibration.

Please remove hands/objects from around the display, calibration will start in 3 seconds…

84

Chapter 7 Diagnostic Menu Section 7.14 Testing Finger Calibration

Page 93

Calibrate Finger Please touch box

Using your finger, touch the four-box grid. The box moves around to the next corner; touch again. Tip: For the calibration to succeed, you need to touch the buttons from the side: Touch the left buttons with your left hand and the right buttons with your right hand. Repeat until you are notified that the test was successful.

7.15

Calibrate Finger

You are notified if the finger calibration was successful.

Calibration Succeeded!

If calibration failed, try again, making sure to follow the preceding tip.

SCV Verification This test is for internal Ingenico use only.

Ingenico 6500 User’s Guide

85