Page 94

Chapter 8

Architecture Overview

8.1

To understand downloading, it helps to understand the architecture of the Ingenico 6500 terminal. Terms explained in this chapter are used in the subsequent chapters. This chapter explains the system architecture, how the unit connects to the host device, and the terminal’s architecture.

System Architecture

8.2

The server (local or remote) sends information to the store controller (if present), which sends it to each host or point of sale device - typically an electronic cash register (ECR), and each ECR sends it to the Ingenico 6500 terminal attached to it. The Ingenico 6500 terminal in turn sends information back through the chain. Figure 1 and Figure 2 illustrate the information flow for stores with and without a store controller. Host Server

Server

Store Controller ECR

Ingenico 6500

Figure 1 Single Unit Architecture

86

ECR

ECR

ECR

Ingenico 6500

Ingenico 6500

Ingenico 6500

Figure 2 Multiple Unit Architecture

Chapter 8 Architecture Section 8.1 Overview

Page 95

8.3

Host Connections The point of sale (POS) system, which can be comprised of the server, store controller, and host devices, communicates with the Ingenico 6500 terminal through an RS-232 or RS-485 serial interface, Ethernet LAN, or USB, depending on the requirements of the host device (typically a computer or ECR). Data is sent using one of these interfaces over a cable that connects the host device to the Ingenico 6500 terminal. The Ingenico 6500 terminal can connect directly to a cash register, computer, Ethernet LAN, or RS485 LAN. Peripherals such as check readers and printers can be connected to the AUX port. Depending on your configuration, there are two to four communication ports. The HOST port, which connects to POS terminals, can connect to the following protocols: RS232, USB/PoweredUSB, RS485 IVI LAN protocol, or RS485 Tailgate protocol (North America only). The AUX port is RS232 for connecting an auxiliary device such as a printer or check reader. The E-NET port (Ethernet 10 base T, TCP/IP) is available on certain configurations. The ITI port is for ISDN and is available in Germany. Note: For instructions on making these connections, refer to the Ingenico 6500 Installation Guide.

8.4

Terminal Architecture LCD MSR

SCR

Millenium ASIC Processor User Application System & Security Application

Maintenance Application

Operating System Store Controller

Stylus

Digitizer Processor

Cash Register Ingenico 6500

Figure 3 Terminal Architecture

Ingenico 6500 User’s Guide

87

Page 96

As illustrated in Figure 3 Terminal Architecture, the Millennium ASIC processor runs programs that act as an interface between the ECR and the Ingenico 6500 terminal: the operating system, system and security application, maintenance application, and user application.

Operating System

8.4.1

The operating system is comprised of several elements. Some of the more prominent ones are explained in this section. Code File System The operating system is separated in several code files, and any application can be implemented as one or several code files. Code files can be run and downloaded independently from each other. The Code File System (CFS) manages the storage of all code files in flash devices. A configuration file lists all the code files composing and describing an application. The System & Security Application manages the CFS. Data File System The Data File System (DFS) manages storage and organization of permanent data. The DFS enables each application to create directories and to store data in files inside flash devices. Human Machine Interface The Human Machine Interface (HMI) peripheral allows applications to interface to the human element of the system through the sensory input/output devices present in the system, such as the display, keypad, and buzzer. Memory Management Unit The Memory Management Unit (MMU) controls memory access permissions, aborting illegal accesses. It protects the memory of the operating system and of each application, so that applications cannot access or destroy data and code in the operating system or in other applications. Each application is fire walled from the other applications using the MMU. Each application runs in its own MMU virtual context that prevents any other applications from accessing its data. The operating system runs inside its own MMU virtual context in supervisor mode. Each application runs inside its own MMU virtual context in user mode. The MMU translates these virtual addresses into physical addresses. The MMU presents the physical memory locations to a program so it can access the code and data. This partitioning prevents any application from accessing other application data or operating system data. All applications are linked at the same virtual address using the MMU. This allows independent development of all applications using the same framework. However, communications between applications are not completely prevented; they are managed through the PAM. Application Manager Peripheral The Application Manager peripheral (PAM) is the main component of the multi-application management system. It is in charge of the management of all UNICAPT32 native applications, which run in the operating system simultaneously. The PAM provides mechanisms that allow synchronization between applications and exchange of data.

88

Chapter 8 Architecture Section 8.4 Terminal Architecture

Page 97

System and Security Application The System and Security Application (SSA) has two modules. The system module contains the terminal’s extended menu, where users can change options related to downloading, diagnostics, system parameters, and system configuration. The security module implements all security requirements, such as key injection and key management. The cryptography functions of the operating system, including key storage areas, are only accessible to the security module. The security module provides a cryptography API to other applications. The SSA blocks any user applications from using the HMI peripheral of the operating system. Thus, all requests by the user application to display forms or receive touch or stylus input must go through the SSA. The SSA then rejects any improper insecure requests, such as:, Activate more than 8 screen buttons (which could be used to create a false PIN pad)., Activate PIN entry with a prompt that has no valid MAC (if the MACing option is on; this prevents the improper collection of the encryption results of known data)., Activate clear text entry with a prompt that has no valid MAC (if the MACing option is on)., Activate clear text entry with a prompt that contains words such as PIN, NIP, etc. (if the MACing option is off)., Retrieve pixel coordinates of individual screen touches (which could be used to create a false PIN pad)., Request more than 30 PIN encryptions within 15 seconds when using MASTER PIN KEY. Maintenance Application The maintenance application is in charge of system components and secure application download. It is an extension of the SSA and the SSA invokes it. It executes before other user applications in order to check version numbers and download new software if needed. The maintenance application communicates with the user application through the peripheral application manager (PAM). The maintenance application has a downloader that communicates with the host in the specified download protocol to receive data and send responses. Each download protocol has its own download application. The maintenance application sends the code files and application data files it receives to the data file system (DFS) first. At the end of download, it releases the COM port, and then requests an offline download from the SSA. The SSA maintenance module performs a security call back to decrypt, unzip, and authenticate the code before it writes the code file to the code file system (CFS). Also, it takes the data files from DFS, goes through the call back function to authenticate it, and puts them in the right place within the DFS. The download port selection, download protocol, and port setting can be set in the supervisor menu (see Chapter 5, Supervisor Menu, on page 23).

Ingenico 6500 User’s Guide

89

Page 98

User Application A user application controls the terminal through customer-specific forms and prompts. User applications are also called payment applications or financial applications. There can be a single user application or multiple ones. User applications vary widely. An application may be thick and contain much business logic, or it may be a thin layer that simply passes on requests from the register. Ingenico provides standard user applications intended for certain markets, or you can create your own user applications using Ingenico’s Ingedev application development environment. In the North American market, standard user applications include Retail Base Application and UPOS interface application. A user application accesses secure functions, such as the display screen, screen buttons, terminal keys, and signature capture, through the security module of the SSA. For all other functions, such as port communications, smart card, and magnetic stripe reader, the user application accesses the operating system directly.

Digitizer

8.4.2

The digitizer is a chip with software on it that handles the interface with the user. It receives finger and stylus input from the display screen, which it sends to the operating system, where it goes first to the human machine interface to be processed. The HMI sends the data to the SSA for security screening. The SSA sends it to the user application.

Transmitting Data

8.4.3

The operating system receives commands from the host (through a port), magnetic stripe reader (MSR), and smart card reader and sends them to the user application. Secure functions, such as display screen, screen buttons, terminal keys, and signature capture, are sent to the SSA for security screening before being sent to the user application. The user application controls the terminal through customer-specific forms and prompts that it sends to the SSA for security screening. The SSA then sends the data to the display screen. The user application uses the operating system to send and receive messages to the host through a port. The operating system provides the user application with debit and credit card information from the MSR and stored value from the smart card reader. The operating system encrypts the user PIN. This encrypted information is sent from the operating system to the user application. From the user application, it goes from the cash register to the store controller, and then on to banks and other processors. The digitizer handles the interface with the user. It receives input from the touch screen and translates it into data that the operating system and SSA can process and encrypt.

90

Chapter 8 Architecture Section 8.4 Terminal Architecture

Page 99

8.5

Download File Architecture The download file is installed on the server. The customer is responsible for sending the code from the server to the electronic cash registers (ECRs). Each ECR sends the code to its Ingenico 6500 terminal. On the POS system, two software components are required: Files to be downloaded to the Ingenico 6500 terminal Downloader, specific to the cash register. Ingenico supports several formats including:, IBM EFT download format, NCR download format, GEMS and GEMS Lite

Ingenico 6500 User’s Guide