The text of a manual · part 10 of 16
Ingenico 6500 User's Guide: System Parameters Menu, pages 73 to 80
Pages 73 to 80 of 126, from Ingenico 6500 User's Guide
The original document is the PDF (881 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Ingenico 6550 / i6550
Page 73
ID
Parameter Name
Description
Value
Data
25
PAR_LAST_DWL_RESULT
Last download result
RES_NO_DWN_ATTEMPT *
Uint8
0 - no download attempt yet. RES_DWN_OK 1- last download result successfully RES_COMM_TX_ERROR 2 - communication transmit error RES_COMM_REC_ERROR 3 - communication receive error RES_QUALIFY_BLOCK_ERROR 4 - qualify data block error RES_BAD_PROG_ERROR 5 - bad program RES_UNSUPPORT_HEADER_ERR OR 6 - Unsupport eftl header file error RES_BAD_INDEX_ERROR 7 - bad program index error RES_NO_DWN_KEY_ERROR 8 - no download key error RES_SCHEDULE_DWN_ERROR 9 - fail to schedule download error RES_SEEK_BLOCK_ERROR 10 - fail seek block error RES_LOST_BLOCK_ERROR 11 - lost block error RES_GET_BLOCK_ERROR 12- fail to get block RES_DECODE_BLOCK_ERROR 13 -fail to decode block RES_CRC_ERROR 14 - crc error RES_COMPLETE_PROGRAM_ER ROR 15 - fail to complete program RES_OPEN_DWN_SESSION_ERR OR 16 - Fail to open download session. RES_SEND_CERTIFIC_ERROR 17 - fail to send certific data.
Ingenico 6500 User’s Guide
65
Page 74
ID
Parameter Name
Description
Value
Data
RES_BDL_CFS_DWN_ERROR 18 - batch download CFS error RES_BDL_DFS_DWN_ERROR 19 – batch download DFS error RES_UPD_EFT_VER_ERROR 20 - fail to update eftl/eftp version RES_LOST_DWN_FILE_ERROR 21 - download file lost error RES_CFS_AUTH_ERROR 22 - cfs authentication error RES_CFS_DEC_ERROR 23- Cfs decryption error RES_DFS_AUTH_ERROR 24 - Dfs authentication error RES_DFS_DEC_ERROR 25 - DFS decryption error RES_FILE_WRITE_ERROR 26 - file write error RES_FILE_READ_ERROR 27 - file read error RES_NO_CFS_SPACE_ERROR 28 - cfs no space error RES_NO_DFS_SPACE_ERROR 29 - Dfs no space error RES_LOST_CERTIFIC_ERROR 30 – lost certific file error RES_UNKNOWN_ERROR 31 - unknown error RES_MEMORY_ERROR 32 – memory error RES_APP_NOT_EXIST 33 - data file application doesn't exist 26
PAR_HOST_PORT_NUM
Port number assigned to the host interface
“COM1” – COM 1* “COM2” – COM2
Char[ 5]
“COM3” – COM3 27
PAR_AUX_PORT_NUM
Port number assigned to the AUX interface
“COM1” – COM1 “COM2” – COM2*
Char[ 5]
“COM3” – COM3
66
Chapter 6 System Parameters Menu Section 6.6 Editing Parameters
Page 75
ID
Parameter Name
Description
Value
28
RESERVED
Download setting reserved.
N/A
29
RESERVED
Download setting reserved.
N/A
30
PAR_COM1_BAUD_RATE
COM1 baud rate setting
1 – COM_BAUD_50
Data
Uint8
2 - COM_BAUD_75 3 - COM_BAUD_150 4 - COM_BAUD_300 5 – COM_BAUD_600 6 – COM_BAUD_1200 7 – COM_BAUD_2400 8 – COM_BAUD_4800 9 – COM_BAUD_9600 10 – COM_BAUD_19200* 11 – COM_BAUD_38400 12 – COM_BAUD_57600 13 – COM_BAUD_76800 14 - COM_BAUD_115200 31
PAR_COM1_DATA_BITS
COM1 data bits setting
1 - COM_DATASIZE_5
Uint8
2 - COM_DATASIZE_6 3 - COM_DATASIZE_7 4 - COM_DATASIZE_8* 32
PAR_COM1_STOP_BITS
COM1 stop bits setting
1 - COM_STOP_1*
Uint8
2 - COM_STOP_2 33
PAR_COM1_PARITY
COM1 parity setting
1 – COM_PARITY_NONE*
Uint8
2 – COM_PARITY_ODD 3 – COM_PARITY_EVEN 34
PAR_COM1_LAN_ADDRES S
COM1 LAN address setting
1 byte number, default = 0x65 uint8
35
PAR_COM1_RETRY_COUN T
COM1 failure retry count
1~10, default 3 times.
uint8
36
PAR_COM1_RESP_TIMEO UT
COM1 response timeout
4 bytes number, 10ms a unit, default = 1000 uint3 2
37
PAR_COM1_POLL_TIMEO UT
COM1 poll timeout
4 bytes number, 10ms a unit, default = 3000 uint3 2
38
PAR_COM1_TURNAROUN D_TIMEOUT
COM1 turn around timeout
4 bytes number, 10ms a unit. default = 300 uint3 2
Ingenico 6500 User’s Guide
67
Page 76
ID
Parameter Name
Description
Value
Data
39
PAR_COM1_INTERFACE_T YPE
COM1 connection interface type
PORT_AUTO uint8
0 – auto detect PORT_RS232 * 1 – RS232 PORT_RS485 2 – RS485 PORT_TAILGATE 3 – Tailgate PORT_USB 4 – USB PORT_ETHERNET 5 – Ethernet PORT_ATMODEM 6 – Dial PORT_3201 7 – 3201
30 ~4 9
RESERVED
COM1 setting reserved.
N/A
50
PAR_COM2_BAUD_RATE
COM2 baud rate setting
1 – COM_BAUD_50
Uint8
2 - COM_BAUD_75 3 - COM_BAUD_150 4 - COM_BAUD_300 5 – COM_BAUD_600 6 – COM_BAUD_1200 7 – COM_BAUD_2400 8 – COM_BAUD_4800 9 – COM_BAUD_9600 10 – COM_BAUD_19200* 11 – COM_BAUD_38400 12 – COM_BAUD_57600 13 – COM_BAUD_76800 14 - COM_BAUD_115200 51
PAR_COM2_DATA_BITS
COM2 data bits setting
1 - COM_DATASIZE_5
Uint8
2 - COM_DATASIZE_6 3 - COM_DATASIZE_7 4 - COM_DATASIZE_8* 52
PAR_COM2_STOP_BITS
COM2 stop bits setting
1 - COM_STOP_1*
Uint8
2 - COM_STOP_2
68
Chapter 6 System Parameters Menu Section 6.6 Editing Parameters
Page 77
ID
Parameter Name
Description
Value
Data
53
PAR_COM2_PARITY
COM2 parity setting
1 – COM_PARITY_NONE*
Uint8
2 – COM_PARITY_ODD 3 – COM_PARITY_EVEN 54
PAR_COM2_LAN_ADDRES S
COM2 LAN address setting
1 byte number, default = 0x65
Uint8
55
PAR_COM2_RETRY_COUN T
COM2 failure retry count
1~10, default 3 times
Uint8
56
PAR_COM2_RESP_TIMEO UT
COM2 response timeout
4 bytes number, >0, 10ms a unit, default=1000
Uint3 2
57
PAR_COM2_POLL_TIMEO UT
COM2 poll timeout
4 bytes number, >0, 10ms a unit, default=3000
Uint3 2
58
PAR_COM2_TURNAROUN D_TIMEOUT
COM2 turn around timeout
4 bytes number, >0, 10ms a unit. , default=300
Uint3 2
59
PAR_COM2_INTERFACE_T YPE
COM2 connection interface type
PORT_RS232 * uint8
1 – RS232 PORT_RS485 2 – RS485 PORT_TAILGATE 3 – Tailgate PORT_USB 4 – USB PORT_ETHERNET 5 – Ethernet PORT_ATMODEM 6 – Dial PORT_3201 7 – 3201
60 ~6 9
RESERVED
Ingenico 6500 User’s Guide
COM2 setting reserved.
N/A
69
Page 78
ID
Parameter Name
Description
Value
Data
70
PAR_COM3_BAUD_RATE
COM3 baud rate setting
1 – COM_BAUD_50
Uint8
2 - COM_BAUD_75 3 - COM_BAUD_150 4 - COM_BAUD_300 5 – COM_BAUD_600 6 – COM_BAUD_1200 7 – COM_BAUD_2400 8 – COM_BAUD_4800 9 – COM_BAUD_9600 10 – COM_BAUD_19200* 11 – COM_BAUD_38400 12 – COM_BAUD_57600 13 – COM_BAUD_76800 14 - COM_BAUD_115200 71
PAR_COM3_DATA_BITS
COM3 data bits setting
1 - COM_DATASIZE_5
Uint8
2 - COM_DATASIZE_6 3 - COM_DATASIZE_7 4 - COM_DATASIZE_8* 72
PAR_COM3_STOP_BITS
COM3 stop bits setting
1 - COM_STOP_1*
Uint8
2 - COM_STOP_2 73
PAR_COM3_PARITY
COM3 parity setting
1 – COM_PARITY_NONE*
Uint8
2 – COM_PARITY_ODD 3 – COM_PARITY_EVEN 74
PAR_ETH_DHCP
Ethernet DHCP setting
0 – NONE*
Uint8
1 – AUTO 75
PAR_ETH_LOCAL_IP_ADD
Ethernet local IP address setting
4 bytes contain the IP address
Uint8 [4]
76
PAR_ETH_LOCAL_IP_POR T
Ethernet local IP port
2 bytes number.
Uint1 6
77
PAR_ETH_REMOTE_IP_AD D
Ethernet remote IP address setting
4 bytes contain the IP address
Uint8 [4]
78
PAR_ETH_REMOTE_IP_PO RT
Ethernet remote IP port
2 bytes number
Uint1 6
79
PAR_COM3_RETRY_COUN T
COM3 failure retry count
1~10, default 3 times
Uint8
80
PAR_COM3_RESP_TIMEO UT
COM3 response timeout
4 bytes number, >0, 10ms a unit, default=1000
Uint3 2
81
PAR_ETH_MASK
Ethernet mask
4 bytes
Uint8 [4]
70
Chapter 6 System Parameters Menu Section 6.6 Editing Parameters
Page 79
ID
Parameter Name
Description
Value
Data
82
PAR_ETH_GATEWAY
Ethernet gateway
4 bytes
Uint8 [4]
83
PAR_ETH_PRIM_DNS
Ethernet primary dns
4 bytes
Uint8 [4]
84
PAR_ETH_SECN_DNS
Ethernet secondary dns
4 bytes
Uint8 [4]
85
PAR_ETH_DOMAIN
Ethernet domain name maximum length of 16 bytes char[ 17]
86
PAR_COM3_INTERFACE_T YPE
COM3 connection interface type
PORT_RS232 uint8
1 – RS232 PORT_RS485 2 – RS485 PORT_TAILGATE 3 – Tailgate PORT_USB 4 – USB PORT_ETHERNET * 5 – Ethernet PORT_ATMODEM 6 – Dial PORT_3201 7 – 3201
87 ~8 9
RESERVED
COM3 setting reserved.
N/A
90 ~9 9
RESERVED
Reserved parameters
N/A
10 0
PAR_MODEM_PHONE_NU M
Modem phone number maximum length of 16 bytes char[ 17]
10 1
PAR_MODEM_SPEED
Modem speed
1 – COM_BAUD_50 uint8
2 - COM_BAUD_75 3 - COM_BAUD_150 4 - COM_BAUD_300 5 – COM_BAUD_600 6 – COM_BAUD_1200 7 – COM_BAUD_2400 8 – COM_BAUD_4800 9 – COM_BAUD_9600 10 – COM_BAUD_19200
Ingenico 6500 User’s Guide
71
Page 80
ID
Parameter Name
Description
Value
Data
11 – COM_BAUD_38400 12 – COM_BAUD_57600 13 – COM_BAUD_76800 14 - COM_BAUD_115200 10 2~
RESERVED
Reserved for modem settings
N/A
11 0
PAR_APPL_COMMENT
Application comment maximum length of 16 bytes
11 1~
RESERVED
Reserved parameters
N/A
PAR_VER_REV_INFO
Version/Revision information for system parameter file.
Maximum length of 16 ASCII bytes, the format is 1byte 1byte 14byte
10 9 char[ 17]
12 6 12 7
72
‘ V
R
Char[ 17]
Comments’
Chapter 6 System Parameters Menu Section 6.6 Editing Parameters