The text of a manual · part 9 of 16
Ingenico 6500 User's Guide: System Parameters Menu, pages 63 to 72
Pages 63 to 72 of 126, from Ingenico 6500 User's Guide
The original document is the PDF (881 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Ingenico 6550 / i6550
Page 63
6.4.19
Setting the Secondary DNS Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port
Press [ ], [Enter] to select Setup Port.
Setup Port
Press [ ], [ ], [Enter] to select Port3, the E-NET port - Ethernet.
Port3
Press [ ] twelve times, then press [Enter] to select Secondary DNS.
Port1 Port2 Port3 Interface Type Baud Rate Data Bits Stop Bits Parity DHCP Local IP Local IP Port Server IP Server IP Port IP Add Mask Gateway Primary DNS Secondary DNS Secondary DNS XXX.XXX.XXX.XXX
Ingenico 6500 User’s Guide
Enter the address of the secondary DNS.
55
Page 64
Updating…
6.4.20
Setting the Domain Name This option is reserved for future use.
6.4.21
Setting Up the Phone Number to Dial If you are using the I.T.I port, you can define a phone number for this port to dial.
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port
Press [ ], [ ], [Enter] to select Setup Port.
Setup Port Port1 Port2 Port3 Dial
56
Press [ ], [ ], [ ], [Enter] to select Dial to configure the I.T.I. port.
Dial Dial Phone Num Modem Speed
Press [Enter] to select Dial Phone Num.
Phone Num Old Value: XXXXX Enter New Value:
Enter the server IP port number.
Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port
Page 65
6.4.22
Setting Up the Modem Speed If you are using the I.T.I port, you can define the modem speed.
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port
Press [ ], [ ], [Enter] to select Setup Port.
Setup Port Port1 Port2 Port3 Dial Dial Dial Phone Num Modem Speed Modem Speed 2400 4800 9600
Press [ ], [ ], [ ], [Enter] to select Dial to configure the I.T.I. port.
Press [ ], [Enter] to select Modem Speed.
Use the arrows to select the appropriate modem speed, and then press [Enter].
Updating
Ingenico 6500 User’s Guide
57
Page 66
6.4.23
Changing the Position of the Host Port or Aux Port The ports are labeled Host, Aux, E-NET, I.T.I., and by default, Port 1 = Host, Port 2 = Aux, Port 3 = Ethernet. However, you may configure Port 1, 2, or 3 as the Host port or Aux port through this menu option. For example, if your host uses Ethernet, you may set your host port as Port 3.
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port
Press [ ], [ ], [Enter] to select Setup Port.
Setup Port Port1 Port2 Port3 Dial Host Port Aux Port Dial COM1 COM2 COM3
Press [ ] until you reach Host or Aux port, and then press [Enter].
Select the COM port you want.
Updating
58
Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port
Page 67
6.5
Configuring the Host Port Auto Detect Feature By default, the Host port is set to automatically detect the communications method being used: RS232, RS485 IVI LAN protocol, RS485 Tailgate protocol, USB, or PoweredUSB.
6.5.1
Disabling or Enabling the Auto Detect Feature By default, the Host port’s Auto Detect feature is enabled.
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port Auto Detect
Press [ ], [ ], [ ], [Enter] to select Auto Detect.
Auto Detect AD On/Off AD Timeout AD Retry Times AD On/Off Off On
Ingenico 6500 User’s Guide
Press [Enter] to select On/Off.
Select the option you want.
59
Page 68
Setting the Auto Detect Timeout
6.5.2
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port Auto Detect
Press [ ], [ ], [ ], [Enter] to select Auto Detect.
Auto Detect AD On/Off AD Timeout AD Retry Times AD Timeout Old Value: XXXXXXXXX Enter New Value:
60
Press [ ], [Enter] to select AD Timeout.
Enter the amount of time after which the unit will cease trying to automatically detect the communications in the Port 1, in units of 1/100 of a second.
Chapter 6 System Parameters Menu Section 6.5 Configuring the Host Port Auto Detect Feature
Page 69
6.5.3
Setting the Auto Detect Retry Times The Auto Detect Retry Times indicates how many times the terminal will attempt a communications protocol before trying the next one on the list. For example, if it is set to 3, when the terminal starts up, it will try 3 times to connect to the HOST in USB mode. If it fails, then it will try 3 times to connect to the HOST in RS485 mode. If it fails, then it will try 3 times to connect to the host in Tailgate mode. If it fails, then it will decide that COM1 is working in RS232 mode. Therefore, the less retry times, the less amount of time it will take to auto-detect the communications type.
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port Auto Detect
Press [ ], [ ], [ ], [Enter] to select Auto Detect.
Auto Detect AD On/Off AD Timeout AD Retry Times AD Retry Times Old Value: XXXXX Enter New Value:
Ingenico 6500 User’s Guide
Press [ ], [ ], [Enter] to select AD Retry Times.
The current value displays. Enter the number of times to retry the auto-detection of the Host port, from 0 to 10.
61
Page 70
Editing Parameters
6.6
This option allows you to edit NAR SSA parameters.
Display
Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu Change Password Application File Security Sys Parameters
Press [ ], [ ], [ ], [Enter] to select Sys Parameters.
Sys Parameters Download Method Download Port Setup Port Auto Detect Parameter Editor
Press [ ] four times, and then press [Enter] to select Parameter Editor.
Parameter ID:
Enter the parameter ID (maximum three digits).
Updating
The following table lists the parameter ID numbers, descriptions, and values. This table is from the internal document, NAR SSA Library: Security Part, version 1.23. The system parameter file is a public file that resides at the root directory of the terminal’s System & Security Application. This file records the system parameter settings made through the supervisor menu. The financial application is allowed to read from this file. Each parameter occupies 16 bytes in the parameter file. A null terminator is required and saved for character strings, except when the string length is 16. In such case, only 16 bytes of data are saved.
62
Chapter 6 System Parameters Menu Section 6.6 Editing Parameters
Page 71
ID
Parameter Name
Description
Value
Data
0
PAR_ENABLE_KEY_BEEP enable/disable beep tone on key entry
FALSE 0 – disable uint8 beep length on key press
0xFFFFFF11 ~ 0xFFFFFF13
1
PAR_KEY_BEEP_LEN
TRUE 1 – enable*
(HMI_BEEP_CLICK* ~ HMI_BEEP_LONG) 2
3
4
PAR_KEY_BEEP_TONE
PAR_DEVICE_TYPE
PAR_LCD_CONTRAST beep frequency on key press
0xFFFFFF01 ~ 0xFFFFFF03
Key entry device or signature capture device.
0 – key entry device
LCD contrast setting for whole device.
0~100
(HMI_BEEP_LOW ~ HMI_BEEP_HIGH)
Uint3 2
Uint3 2
Uint8
1 – signature capture device Uint8 key entry device default contrast = 100, signature cap device default contrast =50
5
PAR_KEY_INJ_PORT
Key injection port setting
“COM1” – com 1*
Char[ 5]
“COM2” – com2 “ETH” - Ethernet 6
PAR_MANUFACTURE_ID
Manufacture ID
“INGNAR”*
Char[ 16]
7
PAR_DEVICE_TYPE_ID
Device type ID e.g. “i6550N”, “i6510N”…
Char[ 16]
8
PAR_BKLT_TIMEOUT
Backlight turn off timeout
8 bytes, 0~0xFFFFFFFFFFFFFFFF*, 10ms a unit, default is always on.
Uint6 4
9
PAR_LCD_BACKLIGHT
LCD backlight
0-100
Uint8
10
PAR_AUTO_DET_RES
Auto detect port 1 result
AUTO_DET_RS232 0 – RS232
Uint8
AUTO_DET_RS485 1 – RS485 AUTO_DET_TALIF_IVILAN 2 – TALIF IVILAN AUTO_DET_TAILGATE 3 – IBM TAILGATE AUTO_DET_USB 11
PAR_AUTO_DET_ONOFF
Auto detect port 1 on or off.
FALSE
0 – off*
TRUE
1 – on
4 – USB Uint8
12
PAR_AUTO_DET_TIMEOU T
Auto detect port 1 timeout
4 bytes. >0, 10ms a unit.
Uint3 2
13
PAR_AUTO_DET_RETRY
Auto detect port 1 retry times.
1 ~ 10
Uint8
14
RESERVED
Auto detect setting reserved
N/A
Ingenico 6500 User’s Guide
63
Page 72
ID
Parameter Name
Description
Value
Data
15
RESERVED
Auto detect setting reserved
N/A
16
RESERVED
Auto detect setting reserved
N/A
17
RESERVED
Auto detect setting reserved
N/A
18
RESERVED
Auto detect setting reserved
N/A
19
RESERVED
Auto detect setting reserved
N/A
20
PAR_EFTL_LEVEL_NUM
EFTL level number
0 ~ 9999
Uint1 6
21
PAR_EFTP_LEVEL_NUM
EFTP level number
0 ~ 9999
Uint1 6
22
PAR_DWL_METHOD
Download method setting
SP_DLLM_IBMEFT
0 – IBMEFT*
SP_DLLM_NCREFT NCREFT
1–
Uint8
SP_DLLM_ZONTALK 2 - ZONTALK SP_DLLM_GEMS
3 - GEMS
SP_DLLM_GERMANY 4 – Germany Security Download 23
PAR_DWL_PORT_NUM
Download port setting
“COM1” – COM 1* “COM2” – COM2
Char[ 5]
“COM3” – COM3 24
PAR_DWL_PORT_TYPE
Download port type setting
PORT_AUTO
Uint8
0 – auto detect (COM1) PORT_RS232 * 1 – RS232 (COM1, COM2) PORT_RS485 2 – RS485 (COM1, COM2) PORT_TAILGATE 3 – Tailgate (COM1) PORT_USB 4 – USB (COM1) PORT_ETHERNET 5 – Ethernet (COM3) PORT_ATMODEM 6 – Dial (COM1, COM2) PORT_3201 7 – 3201 (COM1)
64
Chapter 6 System Parameters Menu Section 6.6 Editing Parameters