Page 63

6.4.19

Setting the Secondary DNS Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Press [ ], [Enter] to select Setup Port.

Setup Port

Press [ ], [ ], [Enter] to select Port3, the E-NET port - Ethernet.

Port3

Press [ ] twelve times, then press [Enter] to select Secondary DNS.

Port1 Port2 Port3 Interface Type Baud Rate Data Bits Stop Bits Parity DHCP Local IP Local IP Port Server IP Server IP Port IP Add Mask Gateway Primary DNS Secondary DNS Secondary DNS XXX.XXX.XXX.XXX

Ingenico 6500 User’s Guide

Enter the address of the secondary DNS.

55

Page 64

Updating…

6.4.20

Setting the Domain Name This option is reserved for future use.

6.4.21

Setting Up the Phone Number to Dial If you are using the I.T.I port, you can define a phone number for this port to dial.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Press [ ], [ ], [Enter] to select Setup Port.

Setup Port Port1 Port2 Port3 Dial

56

Press [ ], [ ], [ ], [Enter] to select Dial to configure the I.T.I. port.

Dial Dial Phone Num Modem Speed

Press [Enter] to select Dial Phone Num.

Phone Num Old Value: XXXXX Enter New Value:

Enter the server IP port number.

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 65

6.4.22

Setting Up the Modem Speed If you are using the I.T.I port, you can define the modem speed.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Press [ ], [ ], [Enter] to select Setup Port.

Setup Port Port1 Port2 Port3 Dial Dial Dial Phone Num Modem Speed Modem Speed 2400 4800 9600

Press [ ], [ ], [ ], [Enter] to select Dial to configure the I.T.I. port.

Press [ ], [Enter] to select Modem Speed.

Use the arrows to select the appropriate modem speed, and then press [Enter].

Updating

Ingenico 6500 User’s Guide

57

Page 66

6.4.23

Changing the Position of the Host Port or Aux Port The ports are labeled Host, Aux, E-NET, I.T.I., and by default, Port 1 = Host, Port 2 = Aux, Port 3 = Ethernet. However, you may configure Port 1, 2, or 3 as the Host port or Aux port through this menu option. For example, if your host uses Ethernet, you may set your host port as Port 3.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Press [ ], [ ], [Enter] to select Setup Port.

Setup Port Port1 Port2 Port3 Dial Host Port Aux Port Dial COM1 COM2 COM3

Press [ ] until you reach Host or Aux port, and then press [Enter].

Select the COM port you want.

Updating

58

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 67

6.5

Configuring the Host Port Auto Detect Feature By default, the Host port is set to automatically detect the communications method being used: RS232, RS485 IVI LAN protocol, RS485 Tailgate protocol, USB, or PoweredUSB.

6.5.1

Disabling or Enabling the Auto Detect Feature By default, the Host port’s Auto Detect feature is enabled.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect

Press [ ], [ ], [ ], [Enter] to select Auto Detect.

Auto Detect AD On/Off AD Timeout AD Retry Times AD On/Off Off On

Ingenico 6500 User’s Guide

Press [Enter] to select On/Off.

Select the option you want.

59

Page 68

Setting the Auto Detect Timeout

6.5.2

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect

Press [ ], [ ], [ ], [Enter] to select Auto Detect.

Auto Detect AD On/Off AD Timeout AD Retry Times AD Timeout Old Value: XXXXXXXXX Enter New Value:

60

Press [ ], [Enter] to select AD Timeout.

Enter the amount of time after which the unit will cease trying to automatically detect the communications in the Port 1, in units of 1/100 of a second.

Chapter 6 System Parameters Menu Section 6.5 Configuring the Host Port Auto Detect Feature

Page 69

6.5.3

Setting the Auto Detect Retry Times The Auto Detect Retry Times indicates how many times the terminal will attempt a communications protocol before trying the next one on the list. For example, if it is set to 3, when the terminal starts up, it will try 3 times to connect to the HOST in USB mode. If it fails, then it will try 3 times to connect to the HOST in RS485 mode. If it fails, then it will try 3 times to connect to the host in Tailgate mode. If it fails, then it will decide that COM1 is working in RS232 mode. Therefore, the less retry times, the less amount of time it will take to auto-detect the communications type.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect

Press [ ], [ ], [ ], [Enter] to select Auto Detect.

Auto Detect AD On/Off AD Timeout AD Retry Times AD Retry Times Old Value: XXXXX Enter New Value:

Ingenico 6500 User’s Guide

Press [ ], [ ], [Enter] to select AD Retry Times.

The current value displays. Enter the number of times to retry the auto-detection of the Host port, from 0 to 10.

61

Page 70

Editing Parameters

6.6

This option allows you to edit NAR SSA parameters.

Display

Action To access the extended menu, restart the terminal by pressing [1] + [CAN] + [OK]; while the terminal is starting up, access the extended menu by pressing the [1] and [3] keys simultaneously.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Press [ ], [ ], [ ], [Enter] to select Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Press [ ], [ ], [ ], [Enter] to select Sys Parameters.

Sys Parameters Download Method Download Port Setup Port Auto Detect Parameter Editor

Press [ ] four times, and then press [Enter] to select Parameter Editor.

Parameter ID:

Enter the parameter ID (maximum three digits).

Updating

The following table lists the parameter ID numbers, descriptions, and values. This table is from the internal document, NAR SSA Library: Security Part, version 1.23. The system parameter file is a public file that resides at the root directory of the terminal’s System & Security Application. This file records the system parameter settings made through the supervisor menu. The financial application is allowed to read from this file. Each parameter occupies 16 bytes in the parameter file. A null terminator is required and saved for character strings, except when the string length is 16. In such case, only 16 bytes of data are saved.

62

Chapter 6 System Parameters Menu Section 6.6 Editing Parameters

Page 71

ID

Parameter Name

Description

Value

Data

0

PAR_ENABLE_KEY_BEEP enable/disable beep tone on key entry

FALSE 0 – disable uint8 beep length on key press

0xFFFFFF11 ~ 0xFFFFFF13

1

PAR_KEY_BEEP_LEN

TRUE 1 – enable*

(HMI_BEEP_CLICK* ~ HMI_BEEP_LONG) 2

3

4

PAR_KEY_BEEP_TONE

PAR_DEVICE_TYPE

PAR_LCD_CONTRAST beep frequency on key press

0xFFFFFF01 ~ 0xFFFFFF03

Key entry device or signature capture device.

0 – key entry device

LCD contrast setting for whole device.

0~100

(HMI_BEEP_LOW ~ HMI_BEEP_HIGH)

Uint3 2

Uint3 2

Uint8

1 – signature capture device Uint8 key entry device default contrast = 100, signature cap device default contrast =50

5

PAR_KEY_INJ_PORT

Key injection port setting

“COM1” – com 1*

Char[ 5]

“COM2” – com2 “ETH” - Ethernet 6

PAR_MANUFACTURE_ID

Manufacture ID

“INGNAR”*

Char[ 16]

7

PAR_DEVICE_TYPE_ID

Device type ID e.g. “i6550N”, “i6510N”…

Char[ 16]

8

PAR_BKLT_TIMEOUT

Backlight turn off timeout

8 bytes, 0~0xFFFFFFFFFFFFFFFF*, 10ms a unit, default is always on.

Uint6 4

9

PAR_LCD_BACKLIGHT

LCD backlight

0-100

Uint8

10

PAR_AUTO_DET_RES

Auto detect port 1 result

AUTO_DET_RS232 0 – RS232

Uint8

AUTO_DET_RS485 1 – RS485 AUTO_DET_TALIF_IVILAN 2 – TALIF IVILAN AUTO_DET_TAILGATE 3 – IBM TAILGATE AUTO_DET_USB 11

PAR_AUTO_DET_ONOFF

Auto detect port 1 on or off.

FALSE

0 – off*

TRUE

1 – on

4 – USB Uint8

12

PAR_AUTO_DET_TIMEOU T

Auto detect port 1 timeout

4 bytes. >0, 10ms a unit.

Uint3 2

13

PAR_AUTO_DET_RETRY

Auto detect port 1 retry times.

1 ~ 10

Uint8

14

RESERVED

Auto detect setting reserved

N/A

Ingenico 6500 User’s Guide

63

Page 72

ID

Parameter Name

Description

Value

Data

15

RESERVED

Auto detect setting reserved

N/A

16

RESERVED

Auto detect setting reserved

N/A

17

RESERVED

Auto detect setting reserved

N/A

18

RESERVED

Auto detect setting reserved

N/A

19

RESERVED

Auto detect setting reserved

N/A

20

PAR_EFTL_LEVEL_NUM

EFTL level number

0 ~ 9999

Uint1 6

21

PAR_EFTP_LEVEL_NUM

EFTP level number

0 ~ 9999

Uint1 6

22

PAR_DWL_METHOD

Download method setting

SP_DLLM_IBMEFT

0 – IBMEFT*

SP_DLLM_NCREFT NCREFT

1–

Uint8

SP_DLLM_ZONTALK 2 - ZONTALK SP_DLLM_GEMS

3 - GEMS

SP_DLLM_GERMANY 4 – Germany Security Download 23

PAR_DWL_PORT_NUM

Download port setting

“COM1” – COM 1* “COM2” – COM2

Char[ 5]

“COM3” – COM3 24

PAR_DWL_PORT_TYPE

Download port type setting

PORT_AUTO

Uint8

0 – auto detect (COM1) PORT_RS232 * 1 – RS232 (COM1, COM2) PORT_RS485 2 – RS485 (COM1, COM2) PORT_TAILGATE 3 – Tailgate (COM1) PORT_USB 4 – USB (COM1) PORT_ETHERNET 5 – Ethernet (COM3) PORT_ATMODEM 6 – Dial (COM1, COM2) PORT_3201 7 – 3201 (COM1)

64