Page 66

UPC-E0 Most U.P.C. barcodes lead with the 0 number system. For these codes, use the UPC-E0 selection. If you need to read codes that lead with the 1 number system. Default = On. UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. Addenda Required When Addenda Required is set to on, the scanner will only read UPC-E barcodes that have addenda. Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space. Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On.

62

Page 67

<Default All UPC-E Settings>

*UPC-E0 On UPC-E0 Off

UPC-E0 Expand On *Off

Addenda Required Required *Not Required

Addenda Separator *On Off

Check Digit *On Off

Number System *On Off

63

Page 68

UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda UPC-E1 Most U.P.C. barcodes lead with the 0 number system. For these codes. If you need to read codes that lead with the 1 number system, use the UPC-E1 selection. Default = Off

Addenda

2 Digit Addenda On *2 Digit Addenda Off

5 Digit Addenda On *5 Digit Addenda Off

UPC-E1 UPC-E1 On *UPC-E1 Off

64

Page 69

EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. ISBN Translate This selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN number format.

<Default All EAN/JAN Settings>

*On Off

Check Digit *On Off

ISBN Translate On *Off

65

Page 70

EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Addenda Required When Addenda required is set to on, the scanner will only read EAN/JAN-13 barcodes that have addenda.

Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space. Addenda 2 Digit Addenda On *2 Digit Addenda Off

5 Digit Addenda On *5 Digit Addenda Off

Addenda Required Required *No Required

Addenda Separator *On Off

66

Page 71

EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda.

<Default All EAN/JAN-8 Settings>

*On Off

Check Digit *On Off

Addenda 2 Digit Addenda On *2 Digit Addenda Off

5 Digit Addenda On *5 Digit Addenda Off

67

Page 72

EAN/JAN-8 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN-8 barcodes that have addenda. EAN/JAN-8 Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space.

Addenda Required Required *Not Required

Addenda Separator *On Off

68

Page 73

MSI MSI Check Character Different types of check characters are used with MSI barcodes. You can program the scanner to read MSI barcodes with Type 10 check characters. When Check Character is set to Validate and Transmit, the scanner will only read MSI barcodes printed with the specified type check character, and will transmit this character at the end of the scanned data. When Check Character is set to Validate, but Don’t Transmit, the unit will only read MSI barcodes printed with the specified type check character, but will not transmit the check character with the scanned data. Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48.

<Default All MSI Settings>

On *Off

*Validate Type 10, but Don’t Transmit

Minimum Message Length

Validate Type 10 and Transmit

Maximum Message Length

69

Page 74

Plessey Code Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48.

<Default All Plessey Code Settings>

On *Off

Minimum Message Length Maximum Message Length

70

Page 75

GS1 DataBar Omnidirectional

<Default All GS1 DataBar Omnidirectional Settings>

*On

Off

GS1 DataBar Limited

<Default All GS1 DataBar Limited Settings>

*On

Off

71