The text of a manual · part 8 of 16
IDAutomation SC7 USB 2D Scanner Programming Manual: Code Option, pages 56 to 65
Pages 56 to 65 of 137, from IDAutomation SC7 USB 2D Scanner Programming Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the ID Automation SC7
Page 56
Straight 2 of 5 Industrial Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
<Default All Straight 2 of 5 Industrial Settings>
On *Off
Minimum Message Length Maximum Message Length
52
Page 57
Straight 2 of 5 IATA Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48
<Default All Straight 2 of 5 IATA Settings>
On *Off Maximum Message Length Minimum Message Length
53
Page 58
Matrix 2 of 5 Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
<Default All Matrix 2 of 5 Settings>
On
*Off Minimum Message Length
Maximum Message Length
54
Page 59
Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits. Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
<Default All Code 11 Settings>
On *Off
One Check Digit *Two Check Digits
Minimum Message Length Maximum Message Length
55
Page 60
Code 128 ISBT 128 Concatenation The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layout for barcodes on a blood product label. Use the barcodes below to turn concatenation on or off. Default = Off. Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the barcode below, select the code page with which the barcodes were created, and scan the value and the Save The data characters should then appear properly. Default = 2.
56
Page 61
<Default All Code 128 Settings>
*On Off
ISBT 128 On
* ISBT 128 Off
Minimum Message Length Maximum Message Length
Code Page
Code 128 Code Page
57
Page 62
Telepen Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output. Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60.
<Default All Telepen Settings>
On *Off
*AIM Telepen Output Original Telepen Output
Minimum Message Length Maximum Message Length
58
Page 63
UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On.
<Default All UPC-A Settings>
*On Off
Check Digit
*On Off
Number System *On Off
59
Page 64
UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data.Default = Off for both 2 Digit and 5 Digit Addenda. Addenda Required When Required is scanned, the scanner will only read UPC-A barcodes that have addenda. You must then turn on a 2 or 5 digit addenda. Default = Not Required. Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space. Default = On. UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. Default = On.
60
Page 65
Addenda
2 Digit Addenda On
*2 Digit Addenda Off
5 Digit Addenda On
*5 Digit Addenda Off
Addenda Required
Required
*Not Required
Addenda Separator
*On Off
UPC-A/EAN-13 with Extended Coupon Code *On Off
61