Page 76

GS1 DataBar Expanded Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.

<Default All GS1 DataBar Expanded Settings>

*On Off

Minimum Message Length

Maximum Message Length

72

Page 77

PosiCode You have to have PosiCode A and B on to read any of the PosiCode symbologies. Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media

<Default All PosiCode Settings>

* On Off

A and B On ( No Limited ) A and B and Limited On ( Limited B Off ) *A and B and Limited B On ( Limited A Off )

Message Length Minimum Message Length Maximum Message Length

Trioptic Code On *Off

73

Page 78

Codablock F Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048

<Default All Codablock F Settings>

On *Off

Minimum Message Length Maximum Message Length

74

Page 79

Code 16K Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160.

<Default All Code 16K Settings>

On *Off

Minimum Message Length Maximum Message Length

75

Page 80

Code 49 Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81.

<Default All Code 49 Settings>

*On Off

Minimum Message Length

Maximum Message Length

76

Page 81

PDF417 Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.

<Default All PDF417 Settings>

*On Off

Minimum Message Length Maximum Message Length

77

Page 82

MicroPDF417 Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.

<Default All Micro PDF417 Settings>

* On Off

Minimum Message Length

Maximum Message Length

78

Page 83

GS1 (EAN•UCC) Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called EAN•UCC Composite symbology. EAN•UCC Composite symbologies allow for the co-existence of symbologies already in use. UPC/EAN Version Scan the UPC/EAN Version On barcode to decode EAN•UCC Composite symbols that have a UPC or EAN linear component. (This does not affect EAN•UCC Composite symbols with a UCC/EAN-128 or GS1 DataBar linear component.) Message Length Scan the barcodes below to change the message length. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435 Emulation The scanner can automatically format the output from any EAN•UCC data carrier to emulate what would be encoded in an equivalent UCC/EAN-128 or GS1 DataBar and Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, UCC/EAN-128, and EAN•UCC GS1 DataBar and Composites. Data from 2D symbols such as Aztec Code, Data Matrix, or QR Code, which encode a leading FNC1, also invoke EAN•UCC emulation. If UCC/EAN-128 Emulation is selected, the AIM Symbology Identifier is reported as “]C1”. If GS1 DataBar Emulation is selected, the AIM Symbology Identifier is reported as “]e0.” Any application that accepts EAN•UCC data can be simplified since it only needs to recognize one data carrier type.

79

Page 84

GS1 (EAN•UCC) Composite Codes TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All barcode readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off. Composite Codes On *Off

UPC/EAN Version UPC / EAN Version On *UPC / EAN Version Off

Message Length Minimum Message Length Maximum Message Length

Emulation GS1 DataBar Emulation

128 Emulation * Emulation Off

TCIF Link Code 39 TLC39 On *TLC39 Off

80

Page 85

Postal Codes Note: For best performance when reading a postal symbology, all other postal symbologies should be turned off; by default all postal symbologies are off. The following postal codes can be enabled.

USPS Intelligent Mail

USPS Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.

On *Off

Transmit Check Digit *Don’t Transmit Check Digit

81